spark_auto_mapper_fhir.value_sets.dicom_controlled_terminology_definitions
¶
Module Contents¶
Classes¶
DICOM Controlled Terminology Definitions |
|
Archive device |
- class spark_auto_mapper_fhir.value_sets.dicom_controlled_terminology_definitions.DICOMControlledTerminologyDefinitionsCode(value)¶
Bases:
spark_auto_mapper_fhir.value_sets.generic_type.GenericTypeCode
DICOM Controlled Terminology Definitions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
DICOM Code Definitions (Coding Scheme Designator “DCM” Coding Scheme Version
“01”)
- Parameters
value (spark_auto_mapper.type_definitions.defined_types.AutoMapperTextInputType) –
- codeset :spark_auto_mapper_fhir.fhir_types.uri.FhirUri = http://dicom.nema.org/resources/ontology/DCM¶
- class spark_auto_mapper_fhir.value_sets.dicom_controlled_terminology_definitions.DICOMControlledTerminologyDefinitionsCodeValues¶
Archive device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Archive¶
Autorefraction device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Autorefraction¶
Angioscopy device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Angioscopy¶
Audio object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Audio¶
Ultrasound Bone Densitometry (modality) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UltrasoundBoneDensitometry¶
Biomagnetic imaging device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiomagneticImaging¶
Bone Mineral Densitometry by X-Ray (modality), including dual-energy X-Ray absorptiometry (DXA) and morphometric X-Ray absorptiometry (MXA) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BoneMineralDensitometry¶
Computer Assisted Detection/Diagnosis device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputerAssistedDetection_Diagnosis¶
Image Capture Device, includes video capture From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageCapture¶
Color flow Doppler From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ColorFlowDoppler¶
Cinefluorography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cinefluorography¶
Computation Server; includes radiotherapy planning From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputationServer¶
Culposcopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Culposcopy¶
Computed Radiography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputedRadiography¶
Cystoscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cystoscopy¶
Computed Tomography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputedTomography¶
Duplex Doppler From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DuplexDoppler¶
Digital fluoroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalFluoroscopy¶
Diaphanography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Diaphanography¶
Digital microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalMicroscopy¶
Equipment that digitized hardcopy documents and imported them From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DocumentDigitizerEquipment¶
Digital Subtraction Angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalSubtractionAngiography¶
Department System Scheduler, workflow manager; includes RIS From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DepartmentSystemScheduler¶
Digital Radiography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalRadiography¶
Echocardiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Echocardiography¶
Electrocardiography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Electrocardiography¶
Cardiac Electrophysiology device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CardiacElectrophysiology¶
Endoscopy device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Endoscopy¶
Female sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Female¶
Fluorescein angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluoresceinAngiography¶
Female sex changed to Male sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemaleChangedToMale¶
Film Digitizer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FilmDigitizer¶
Female Pseudohermaphrodite From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemalePseudohermaphrodite¶
Fundoscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fundoscopy¶
General Microscopy device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GeneralMicroscopy¶
Hermaphrodite From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hermaphrodite¶
Hard Copy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HardCopy¶
Hemodynamic Waveform acquisition device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemodynamicWaveform¶
Intra-oral Radiography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Intra_oralRadiography¶
An acquisition device, process or method that performs intravascular optical coherence tomography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntravascularOpticalCoherenceTomography¶
Intravascular Ultrasound device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntravascularUltrasound¶
Keratometry device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Keratometry¶
Key Object Selection object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KeyObjectSelection¶
Lensometry device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Lensometry¶
Procedure Logging device; includes cath lab logging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureLogging¶
Laparoscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Laparoscopy¶
Laser surface scan device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LaserSurfaceScan¶
Male sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Male¶
Magnetic resonance angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MagneticResonanceAngiography¶
Male sex changed to Female sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaleChangedToFemale¶
A device that creates DICOM PS3.10 interchange media; e.g. a CD creator that is managed by the Media Creation Management Service Class From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MediaCreationDevice¶
Equipment that retrieved and imported objects from interchange Media From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PortableMediaImporterEquipment¶
Mammography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mammography¶
Male Pseudohermaphrodite From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MalePseudohermaphrodite¶
Magnetic Resonance device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MagneticResonance¶
Magnetic resonance spectroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MagneticResonanceSpectroscopy¶
Instances need to be retrieved from relatively slow media such as optical disk or tape From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Nearline¶
Nuclear Medicine device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NuclearMedicine¶
Measurements of the axial length of the eye, which are done by various devices From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicAxialMeasurements¶
Modality device that uses an interferometric, non-invasive optical tomographic technique to image 2D slices and 3D volumes of tissue using visible and near visible frequencies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OpticalCoherenceTomography¶
Instances need to be retrieved by manual intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Offline¶
Instances are immediately available From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Online¶
Ophthalmic photography modality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicPhotography¶
Modality device that measures corneal topography, corneal or retinal thickness, and other similar parameters that are typically displayed as maps From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicMapping¶
Modality device that measures the refractive characteristics of the eye From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicRefraction¶
Tomography of the eye acquired by a modality that is based on light and optical principles. Tomography based on other principles, such as ultrasound, is excluded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicTomography¶
Modality device that measures visual fields and perform visual perimetry From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicVisualField¶
An acquisition device, process or method that performs optical surface scanning From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OpticalSurvaceScanner¶
Other Modality device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherModality¶
Presentation State object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PresentationState¶
Hard Copy Print Server; includes printers with embedded DICOM print server From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HardCopyPrintServer¶
Positron emission tomography (PET) device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositronEmissionTomography¶
Panoramic X-Ray device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PanoramicX_Ray¶
Registration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Registration¶
Radiofluoroscopy device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Radiofluoroscopy¶
Radiographic imaging (conventional film/screen) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiographicImaging¶
Radiation Therapy Device; includes linear accelerator, proton therapy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationTherapyDevice¶
Radiotherapy Dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiotherapyDose¶
Radiotherapy Imaging device; includes portal imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiotherapyImage¶
Radiotherapy Plan From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiotherapyPlan¶
Radiotherapy Treatment Record From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiotherapyTreatmentRecord¶
Radiotherapy Structure Set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiotherapyStructureSet¶
Segmentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Segmentation¶
Slide Microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SlideMicroscopy¶
Stereometric image pairing modality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StereometricRelationship¶
Structured Report Document From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StructuredReportDocument¶
Subjective Refraction device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectiveRefraction¶
Single-photon emission computed tomography (SPECT) device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Single_photonEmissionComputedTomography¶
Thermography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Thermography¶
Unknown Sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnknownSex¶
Instances cannot be retrieved From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
Ultrasound device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ultrasound¶
Visual Acuity device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualAcuity¶
Videofluorography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Videofluorography¶
Equipment that digitizes video tape and imports it From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VideoTapeDigitizerEquipment¶
Workstation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Workstation¶
X-Ray Angiography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayAngiography¶
External-camera Photography device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- External_cameraPhotography¶
A signal transmitted for the purpose of interchange of the current time, not specific to any source or methodology From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalTimecode_NOS_¶
A signal that is generated for each detection of a heart beat From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ECG_basedGatingSignal_Processed¶
A signal transmitted by the Inter-Range Instrumentation Group for the purpose of synchronizing time clocks From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IRIG_BTimecode¶
A signal that indicated that X-Ray source has been activated for fluoroscopy use From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFluoroscopyOnSignal¶
A signal that indicated that the X-Ray source has been activated for image recording From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayOnTrigger¶
An electrical signal derived from two electrodes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferentialSignal¶
An electrophysiological recording from the HIS nerve bundle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HisBundleElectrogram¶
An electrical signal from one electrode relative to an indifferent potential From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MonopoleSignal¶
The voltage stimulus during cardiac pacing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pacing_electrical_Stimulus_Voltage¶
The power injected during RF ablation procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadioFrequencyAblation_Power¶
Electrophysiological signals acquired using a multi-splined catheter each equipped with multiple electrodes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VoltageMeasurementByBasketCatheter¶
Electrophysiological signals acquired using a steerable catheter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VoltageMeasurementByMappingCatheter¶
A voltage measurement not otherwise specified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VoltageMeasurement_NOS¶
A signal point that is 35% of the peak thermal cardiac output signal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AWavePeakPressure¶
The average of several A wave pressure measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AWavePressure_Average¶
An identified cardiac beat used in the determination of a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeatDetected_accepted_¶
An identified cardiac beat not used in the determination of a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeatDetected_rejected_¶
The average of several diastolic pressure measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiastolicPressure_Average¶
The lowest pressure value excluding any undershoot artifact From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiastolicPressureNadir¶
The moment at the end of the diastolic phase of the cardiac cycle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndDiastole¶
The moment at the end of respiratory expiration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndOfExpiration¶
The moment at the end of respiratory inspiration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndOfInspiration¶
The maximum positive rate of change of pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaxDp_dt¶
The maximum negative rate of change of pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaxNegDp_dt¶
The average blood pressure value, generally over 2 or more seconds From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanBloodPressure¶
The peak change in blood temperature during a thermal cardiac output measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakOfThermalCardiacOutputBolus¶
The moment respiratory expiration begins From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfExpiration¶
The moment of respiratory inspiration begins From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfInspiration¶
The first discernible blood temperature change following the injectate during a thermal cardiac output measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfThermalCardiacOutputBolus¶
The average of several systolic blood pressure measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystolicPressure_Average¶
The highest systolic blood pressure value excluding any overshoot artifact From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystolicPeakPressure¶
The peak pressure of each heart beat in the atrium caused by the filling of the atrium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VWavePeakPressure¶
The average of several V wave pressure measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VWavePressure_Average¶
The moment at which a heart valve closes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValveClose¶
The moment at which a heart valve opens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValveOpen¶
The moment when RF ablation current is turned off From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AblationOff¶
The moment when RF ablation current is turned on From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AblationOn¶
The moment in the cardiac cycle when the HIS bundle nerves depolarize From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HISBundleWave¶
The surface electrocardiogram of the atrial contraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PWave¶
The first negative deflection of the electrocardiogram caused by ventricular depolarization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QWave¶
The first positive deflection the electrocardiogram caused by ventricular depolarization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RWave¶
The first negative deflection after the R wave From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SWave¶
The beginning of the atrial contraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfAtrialContraction¶
The beginning of the second atrial contraction of two consecutive beats From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfAtrialContraction_subsequent_¶
The stimulation interval during cardiac stimulation first used in a pacing train From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StimulationAtRate1Interval¶
The stimulation interval different from the first stimulation interval used in a pacing train From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StimulationAtRate2Interval¶
A stimulation interval different from and subsequent to the second interval in a pacing train From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StimulationAtRate3Interval¶
Describes a stimulation interval different from and subsequent to the third interval in a pacing train From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StimulationAtRate4Interval¶
The electrocardiogram deflection caused by ventricular repolarization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TWave¶
The peak pressure of each heart beat monitored in the atrium caused by the filling of the atrium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VWave¶
The second V wave measurement of two consecutive beats From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VWaveOfNextBeat¶
A description of the physiological condition of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientState¶
The exercise level during a progressive cardiac stress test From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProtocolStage¶
A series of physiological challenges designed to progressively increase the work of the heart From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StressProtocol¶
A subpart of a cardiac catheterization procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CatheterizationProcedurePhase¶
The subpart of a cardiac catheterization procedure in which a radio-opaque contrast medium is injected into the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastPhase¶
Physical changes administered to a patient in order to elicit an physiological response From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhysiologicalChallenges¶
Enumeration of a subpart of a catheterization procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureStepNumber¶
A subpart of an electrophysiological procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EPProcedurePhase¶
A means of defining a series of cardiac stimulation pulses From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulseTrainDefinition¶
End of the contraction phase of the cardiac cycle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndOfSystole¶
Time for a median particle to travel from point of injection to point of detection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndicatorMeanTransitTime¶
The time constant of isovolumic pressure fall From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Tau¶
Maximum velocity of myocardial contractility From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VMaxMyocardial¶
Total time for the acquisition is shorter than cardiac cycle, no gating is applied; see Cardiac Synchronization Technique (0018,9037) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RealTimeAcquisition¶
Certain thresholds have been set for a gating window that defines the acceptance of measurement data during the acquisition; see Cardiac Synchronization Technique (0018,9037) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProspectiveGating¶
Certain thresholds have been set for a gating window that defines the acceptance of measurement data after the acquisition; see Cardiac Synchronization Technique (0018,9037) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetrospectiveGating¶
There is a constant RR interval, which makes thresholding not required; see Cardiac Synchronization Technique (0018,9037); e.g. Pacemaker From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Paced¶
Imaging after injection of tracer during increased cardiac workload or increased myocardial blood flow, achieved by either exercise or pharmacologic means From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CardiacStressState¶
Imaging after injection of additional tracer under resting conditions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReinjectionState¶
Imaging after allowing a moderate amount of time for tracer to move from its initial sites of uptake. Example: For Thallium imaging this would correspond to imaging 2-6 hours after injection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RedistributionState¶
Imaging after allowing an extended amount of time for tracer to move from its initial sites of uptake. Example: For Thallium imaging this would correspond to imaging more than 6 hours after injection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DelayedRedistributionState¶
Peak cardiac stress state From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakStressState¶
Recovery from cardiac stress From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecoveryState¶
Equipment that originally acquired the data stored within composite instances; e.g. a CT, MR or Ultrasound modality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionEquipment¶
Equipment that has processed composite instances to create new composite instances; e.g. a 3D Workstation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcessingEquipment¶
Equipment that has modified existing composite instances (without creating new composite instances); e.g. a QA Station or Archive From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ModifyingEquipment¶
Equipment that has modified an existing composite instance to remove patient identifying information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- De_identifyingEquipment¶
Equipment that has processed composite instances to create new composite instances by extracting selected frames from the original instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FrameExtractingEquipment¶
Equipment that has processed composite instances to create new composite instances by converting classic single frame images to enhanced multi-frame image, or vice versa and updating other instances to maintain referential integrity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EnhancedMulti_frameConversionEquipment¶
The sound of a human’s speech, recorded during a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Voice¶
The voice of a device operator, recorded during a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Operator_sNarrative¶
The ambient sound recorded during a procedure, which may or may not include voice and other types of sound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmbientRoomEnvironment¶
The Doppler waveform recorded as an audible signal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DopplerAudio¶
The sound of the human heart beating From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Phonocardiogram¶
Any sound made by the human body From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhysiologicalAudioSignal¶
A digitized signal from the patient arterial system collected through pulse oximetry or other means From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArterialPulseWaveform¶
A digitized signal from the patient respiratory system representing respiration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RespirationWaveform¶
The occasion on which a procedure was performed on admission to a specialist unit; e.g. intensive care From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OnAdmissionToUnit¶
The occasion on which a procedure was performed on discharge from hospital as an in-patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OnDischarge¶
The occasion on which a procedure was performed on discharge from a specialist unit; e.g. intensive care From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OnDischargeFromUnit¶
The occasion on which a procedure was performed immediately prior to non- surgical intervention; e.g, percutaneous angioplasty, biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pre_intervention¶
The occasion on which a procedure was performed immediately after to non- surgical intervention; e.g, percutaneous angioplasty, biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Post_intervention¶
The occasion on which a procedure was performed at the most recent outpatient visit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AtLastAppointment¶
The active or passive joint positioning during acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- JointPositionMethod¶
A physical force applied during acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhysicalForce¶
Prior to voiding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PriorToVoiding¶
Post voiding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PostVoiding¶
Neutral musculoskeletal position From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeutralMusculoskeletalPosition¶
America Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmericaKennelClub¶
America’s Pet Registry Inc From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- America_sPetRegistryInc_¶
American Canine Association From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmericanCanineAssociation¶
American Purebred Registry From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmericanPurebredRegistry¶
American Rare Breed Association From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmericanRareBreedAssociation¶
Animal Registry Unlimited From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnimalRegistryUnlimited¶
Animal Research Foundation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnimalResearchFoundation¶
Canadian Border Collie Association From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CanadianBorderCollieAssociation¶
Canadian Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CanadianKennelClub¶
Canadian Livestock Records Association From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CanadianLivestockRecordsAssociation¶
Canine Federation of Canada From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CanineFederationOfCanada¶
Continental Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContinentalKennelClub¶
Dog Registry of America From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DogRegistryOfAmerica¶
Federation of International Canines From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FederationOfInternationalCanines¶
International Progressive Dog Breeders’ Alliance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InternationalProgressiveDogBreeders_Alliance¶
National Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NationalKennelClub¶
North American Purebred Dog Registry From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NorthAmericanPurebredDogRegistry¶
United All Breed Registry From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnitedAllBreedRegistry¶
United Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnitedKennelClub¶
Universal Kennel Club International From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UniversalKennelClubInternational¶
Working Canine Association of Canada From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WorkingCanineAssociationOfCanada¶
World Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WorldKennelClub¶
World Wide Kennel Club From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WorldWideKennelClub¶
Evaluation of overall image quality as described in section 7.3.2 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OverallImageQualityEvaluation¶
Visual verification of sufficient grayscale resolution based on 8 and 10-bit markers as described in section 7.3.3 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GrayscaleResolutionEvaluation¶
Visual evaluation of luminance response using the TG18-CT test pattern as described in section 7.3.4 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LuminanceResponseEvaluation¶
Visual detection of luminance non-uniformities as described in section 7.3.5 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LuminanceUniformityEvaluation¶
Visual verification of color uniformity as described in section 7.3.6 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ChromaticityEvaluation¶
Visual detection of defective pixels on dark (TG18-UN80) and bright (TG18-UN10) images as described in section 7.3.7 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelFaultsEvaluation¶
Visual evaluation of veiling glare by looking at low contrast objects on 2 test patterns as described in section 7.3.8 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VeilingGlareEvaluation¶
Visual evaluation of geometry, phase/clock correction and clipping as described in section 7.3.9 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GeometricalImageEvaluation¶
Visual evaluation of viewing angle as described in section 7.3.10 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AngularViewingEvaluation¶
Visual evaluation of the appearance of clinical images as described in section 7.3.11 of [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClinicalEvaluation¶
AAPM TG18-QC Pattern used for evaluation of resolution, luminance, distortion, artifacts. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_QCPattern¶
AAPM TG18-BR Pattern used for the evaluation of the display of low-contrast, fine-detail image structures See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_BRPattern¶
AAPM TG18-PQC Pattern used for evaluation of resolution, luminance, contrast transfer for prints. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_PQCPattern¶
AAPM TG18-CT Pattern used for evaluation of luminance response. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_CTPattern¶
The 1st image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_01Pattern¶
The 2nd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_02Pattern¶
The 3rd image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_03Pattern¶
The 4th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_04Pattern¶
The 5th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_05Pattern¶
The 6th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_06Pattern¶
The 7th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_07Pattern¶
The 8th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_08Pattern¶
The 9th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_09Pattern¶
The 10th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration series. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_10Pattern¶
The 11th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_11Pattern¶
The 12th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_12Pattern¶
The 13th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_13Pattern¶
The 14th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_14Pattern¶
The 15th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_15Pattern¶
The 16th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_16Pattern¶
The 17th image in the AAPM TG18-LN8 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_17Pattern¶
The 18th image in the AAPM TG18-LN8- set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN8_18Pattern¶
The 1st image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_01Pattern¶
The 2 nd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_02Pattern¶
The 3rd image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_03Pattern¶
The 4th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_04Pattern¶
The 5th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_05Pattern¶
The 6th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_06Pattern¶
The 7th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_07Pattern¶
The 8th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_08Pattern¶
The 9th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_09Pattern¶
The 10th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_10Pattern¶
The 11th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_11Pattern¶
The 12th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_12Pattern¶
The 13th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_13Pattern¶
The 14th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_14Pattern¶
The 15th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_15Pattern¶
The 16th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_16Pattern¶
The 17th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_17Pattern¶
The 18th image in the AAPM TG18-LN12 set used for DICOM grayscale calibration. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LN12_18Pattern¶
The AAPM TG18-UN10 Pattern used for evaluation of luminance and color uniformity, and angular response. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_UN10Pattern¶
The AAPM TG18-UN80 Pattern used for evaluation of luminance and color uniformity, and angular response. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_UN80Pattern¶
The AAPM TG18-UNL10 Pattern is the AAPM TG-18 UN10 Pattern with added defining lines. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_UNL10Pattern¶
The AAPM TG18-UNL80 Pattern is the AAPM TG-18 UN80 Pattern with added defining lines. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_UNL80Pattern¶
The AAPM TG18-AD Pattern used for visual evaluation of the reflection of ambient light from the display. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_ADPattern¶
The AAPM TG18-MP Pattern used for evaluation of Luminance response (bit-depth resolution). See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_MPPattern¶
The AAPM TG18-RH10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 10% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RH10Pattern¶
The AAPM TG18-RH50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 50% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RH50Pattern¶
The AAPM TG18-RH89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 horizontal lines at 89% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RH89Pattern¶
The AAPM TG18-RV10 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 10% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RV10Pattern¶
The AAPM TG18-RV50 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 50% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RV50Pattern¶
The AAPM TG18-RV89 Pattern used for LSF-line spectra function-(1k and 2k) evaluation by 5 vertical lines at 89% luminance level. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_RV89Pattern¶
The AAPM TG18-PX Pattern used for the assessment of display resolution. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_PXPattern¶
The AAPM TG18-CX Pattern used to assess display resolution and resolution uniformity. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_CXPattern¶
The AAPM TG18-LPH10 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPH10Pattern¶
The AAPM TG18-LPH50 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 50% positive contrast against 10% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPH50Pattern¶
The AAPM TG18-LPH89 Pattern used to assess display resolution. This pattern has horizontal bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPH89Pattern¶
The AAPM TG18-LPV10 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 10% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPV10Pattern¶
The AAPM TG18-LPV50 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 50% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPV50Pattern¶
The AAPM TG18-LPV89 Pattern used to assess display resolution. This pattern has vertical bars consisting of alternating single-pixel-wide lines across the faceplate of display. The lines have a 12% positive contrast against 89% background level of the maximum pixel value. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_LPV89Pattern¶
The AAPM TG18-AFC Pattern used to assess display noise. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_AFCPattern¶
The AAPM TG18-NS10 Pattern is AAPM TG18-RV10/RH10 with only difference being the absence of the single line at the center of the measurement area. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_NS10Pattern¶
The AAPM TG18-NS50 Pattern is AAPM TG18-RV50/RH50 with only difference being the absence of the single line at the center of the measurement area. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_NS50Pattern¶
The AAPM TG18-NS89 Pattern is AAPM TG18-RV89/RH89 with only difference being the absence of the single line at the center of the measurement area. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_NS89Pattern¶
The TG18-GV Pattern used to assess display veiling. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GVPattern¶
The TG18-GVN Pattern used to assess display veiling. This pattern is identical to AAPM TG18-GV Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GVNPattern¶
The TG18-GQ Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GV except that is lacks the central low-contrast objects. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GQPattern¶
TG18-GQN Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except that the large-diameter white circle is replaced with a black circle, creating a completely black pattern except for the presence of low-contrast targets. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GQNPattern¶
The TG18-GQB Pattern used for the quantitative assessment of veiling glare. This pattern is identical to AAPM TG18-GQ Pattern except eliminating the central black circle. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GQBPattern¶
The TG18-GA03 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 3. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA03Pattern¶
The TG18-GA05 Pattern This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 5. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA05Pattern¶
The TG18-GA08 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 8. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA08Pattern¶
The TG18-GA10 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 10. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA10Pattern¶
The TG18-GA15 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 15 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA15Pattern¶
The TG18-GA20 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 20. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA20Pattern¶
The TG18-GA25 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 25. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA25Pattern¶
The TG18-GA30 Pattern used for quantitative assessment of veiling glare. This pattern is identical to TG18-GQ except that the radius of the central black circle is varied as r = 30. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_GA30Pattern¶
The AAPM TG18-CH Image is a reference anatomical PA chest image. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_CHImage¶
The AAPM TG18-KN Image is a reference anatomical knee image. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_KNImage¶
The AAPM TG18-MM1 Image is a reference anatomical mammogram image. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_MM1Image¶
The AAPM TG18-MM2 Image is a reference anatomical mammogram image. See [AAPM OR 03] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TG18_MM2Image¶
The IEC OIQ Pattern is used as an alternative to the TG18-QC Pattern. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OIQPattern¶
The IEC ANG Pattern used for angular viewing evaluation. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ANGPattern¶
The IEC GD Pattern used for geometrical image evaluation. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GDPattern¶
The IEC BN01 Pattern is used as analternative to the TG18-LN-01 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN01Pattern¶
The IEC BN02 Pattern is used as analternative to the TG18-LN-02 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN02Pattern¶
The IEC BN03 Pattern is used as analternative to the TG18-LN-03 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN03Pattern¶
The IEC BN04 Pattern is used as analternative to the TG18-LN-04 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN04Pattern¶
The IEC BN05 Pattern is used as analternative to the TG18-LN-05 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN05Pattern¶
The IEC BN06 Pattern is used as analternative to the TG18-LN-06 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN06Pattern¶
The IEC BN07 Pattern is used as analternative to the TG18-LN-07 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN07Pattern¶
The IEC BN08 Pattern is used as analternative to the TG18-LN-08 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN08Pattern¶
The IEC BN09 Pattern is used as analternative to the TG18-LN-09 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN09Pattern¶
The IEC BN10 Pattern is used as analternative to the TG18-LN-10 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN10Pattern¶
The IEC BN11 Pattern is used as analternative to the TG18-LN-11 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN11Pattern¶
The IEC BN12 Pattern is used as analternative to the TG18-LN-12 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN12Pattern¶
The IEC BN13 Pattern is used as analternative to the TG18-LN-13 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN13Pattern¶
The IEC BN14 Pattern is used as analternative to the TG18-LN-14 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN14Pattern¶
The IEC BN15 Pattern is used as analternative to the TG18-LN-15 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN15Pattern¶
The IEC BN16 Pattern is used as analternative to the TG18-LN-16 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN16Pattern¶
The IEC BN17 Pattern is used as analternative to the TG18-LN-17 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN17Pattern¶
The IEC BN18 Pattern is used as analternative to the TG18-LN-18 Pattern, to avoid the use of a cone or baffle with LCDs. See [IEC 62563-1] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BN18Pattern¶
Test image “Bild 2” for the gray-scale reproduction of imaging devices. See [DIN 6868-57] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DINGrayscalePattern¶
Test image “Bild 3” for the geometrical imaging properties of imaging devices. See [DIN 6868-57] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DINGeometryPattern¶
Test image “Bild 5” for displaying the spatial and contrast resolution as well as the line structure of imaging devices. See [DIN 6868-57] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DINResolutionPattern¶
An alternative to AAPM TG18-UN80, specified at 100% of maximum pixel value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WhitePattern¶
A standard display test pattern. See [SMPTE RP133]. A pattern is available at http://www.dclunie.com/images/smpte.512.512.8.gif From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SMPTEPattern¶
A Display Device that displays images on a Cathode Ray Tube From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CRTDisplay¶
A Display Device that displays images on a Liquid Crystal Display From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LiquidCrystalDisplay¶
A Display Device that displays images on a Plasma Display From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlasmaDisplay¶
A Display Device that displays images on an Organic Light Emitting Diode based display From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OLED¶
A Display Device that projects images on a surface from behind using a Digital Light Processing Projector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPRearProjectionSystem¶
A Display Device that projects images on a surface from in front using a Digital Light Processing Projector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPFrontProjectionSystem¶
A Display Device that projects images on a surface from behind using a Cathode Ray Tube From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CRTRearProjectionSystem¶
A Display Device that projects images on a surface from in front using a Cathode Ray Tube From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CRTFrontProjectionSystem¶
A Display Device that projects images on a surface from an unspecified direction using an unspecified means From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherProjectionSystem¶
Image processing work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageProcessing¶
Quality control work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityControl¶
Computer aided diagnosis work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputerAidedDiagnosis¶
Computer aided detection work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputerAidedDetection¶
Interpretation work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Interpretation¶
Transcription work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Transcription¶
Report verification work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReportVerification¶
Print work item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Print¶
There will be no more work items scheduled From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoSubsequentWorkitems¶
Film type of output From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Film¶
Dictation type of output From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Dictation¶
Transcription type of output From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Transcription¶
The procedure to read DICOM instances from DICOM interchange media, coerce identifying attributes into the local namespace if necessary, and make the instances available From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MediaImport¶
Digitization of Sheet Film From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SheetFilmDigitized¶
Digitization of Cine Film From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CineFilmDigitized¶
Digitization of Video Tape From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VideoTapeDigitized¶
Digitization of pages of a paper document (Units may be specified as Pages, Documents) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PaperDigitized¶
Importation of CD From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CDImported¶
Importation of DVD From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DVDImported¶
Importation of MOD From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MODImported¶
Importation of DICOM Studies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StudiesImported¶
Importation of DICOM Composite Instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InstancesImported¶
A device that connects using the USB hard drive interface. These may be USB- Sticks, portable hard drives, and other technologies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- USBDiskEmulation¶
Email and email attachments used as a media for data transport From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Email¶
CD-R, CD-ROM, and CD-RW media used for data transport From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CD¶
DVD, DVD-RAM, and other DVD formatted media used for data transport From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DVD¶
Media that comply with the Compact Flash standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompactFlash¶
Media that comply with the Multi-media Card standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Multi_mediaCard¶
Media that comply with the Secure Digital Card standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SecureDigitalCard¶
URI Identifier for network or other resource, see RFC 3968 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- URI¶
Any paper or similar document From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PaperDocument¶
Audit event: Application Activity has taken place From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApplicationActivity¶
Audit event: Audit Log has been used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AuditLogUsed¶
Audit event: Storage of DICOM Instances has begun From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeginTransferringDICOMInstances¶
Audit event: DICOM Instances have been created, read, updated, or deleted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DICOMInstancesAccessed¶
Audit event: Storage of DICOM Instances has been completed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DICOMInstancesTransferred¶
Audit event: Entire Study has been deleted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DICOMStudyDeleted¶
Audit event: Data has been exported out of the system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Export¶
Audit event: Data has been imported into the system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Import¶
Audit event: System has joined or left network From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NetworkEntry¶
Audit event: Order has been created, read, updated or deleted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrderRecord¶
Audit event: Patient Record has been created, read, updated, or deleted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientRecord¶
Audit event: Procedure Record has been created, read, updated, or deleted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureRecord¶
Audit event: Query has been made From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Query¶
Audit event: Security Alert has been raised From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SecurityAlert¶
Audit event: User Authentication has been attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UserAuthentication¶
Audit event: Application Entity has started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApplicationStart¶
Audit event: Application Entity has stopped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApplicationStop¶
Audit event: User login has been attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Login¶
Audit event: User logout has been attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Logout¶
Audit event: Node has been attached From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Attach¶
Audit event: Node has been detached From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Detach¶
Audit event: Node Authentication has been attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NodeAuthentication¶
Audit event: Emergency Override has started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EmergencyOverrideStarted¶
Audit event: Network configuration has been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NetworkConfiguration¶
Audit event: Security configuration has been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SecurityConfiguration¶
Audit event: Hardware configuration has been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HardwareConfiguration¶
Audit event: Software configuration has been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SoftwareConfiguration¶
Audit event: A use of a restricted function has been attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UseOfRestrictedFunction¶
Audit event: Audit recording has been stopped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AuditRecordingStopped¶
Audit event: Audit recording has been started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AuditRecordingStarted¶
Audit event: Security attributes of an object have been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectSecurityAttributesChanged¶
Audit event: Security roles have been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SecurityRolesChanged¶
Audit event: Security attributes of a user have been changed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UserSecurityAttributesChanged¶
Audit event: Emergency Override has Stopped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EmergencyOverrideStopped¶
Audit event: Remote Service Operation has Begun From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RemoteServiceOperationStarted¶
Audit event: Remote Service Operation has Stopped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RemoteServiceOperationStopped¶
Audit event: Local Service Operation has Begun From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocalServiceOperationStarted¶
Audit event: Local Service Operation Stopped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocalServiceOperationStopped¶
Audit participant role ID of software application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Application¶
Audit participant role ID of software application launcher, i.e., the entity that started or stopped an application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApplicationLauncher¶
Audit participant role ID of the receiver of data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DestinationRoleID¶
Audit participant role ID of the sender of data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceRoleID¶
Audit participant role ID of media receiving data during an export From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DestinationMedia¶
Audit participant role ID of media providing data during an import From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceMedia¶
ParticipantObjectID type: Study Instance UID From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StudyInstanceUID¶
ParticipantObjectID type: SOP Class UID From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SOPClassUID¶
ID of a node that is a participant object of an audit message From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NodeID¶
System, organization, agency, or department that has assigned an instance identifier (such as placer or filler number, patient or provider identifier, etc.) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IssuerOfIdentifier¶
Procedure order canceled by requesting physician or other authorized physician From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoctorCanceledProcedure¶
Equipment failure prevented completion of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentFailure¶
Procedure discontinued due to incorrect procedure being ordered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IncorrectProcedureOrdered¶
Procedure discontinued due to patient allergy to media/contrast (reported or reaction) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAllergicToMedia_contrast¶
Procedure discontinued due to death of Patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDied¶
Procedure discontinued due to patient refusal to continue procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientRefusedToContinueProcedure¶
Procedure discontinued due to patient being taken for treatment or surgery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTakenForTreatmentOrSurgery¶
Patient did not arrive for procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDidNotArrive¶
Procedure discontinued due to patient pregnancy (reported or determined) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientPregnant¶
Procedure discontinued to restart with new procedure code for correct charging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ChangeOfProcedureForCorrectCharging¶
Procedure discontinued due to duplicate orders received for same procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DuplicateOrder¶
Procedure order canceled by nursing unit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NursingUnitCancel¶
Procedure discontinued due to incorrect side (laterality) being ordered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IncorrectSideOrdered¶
Procedure discontinued for unspecified reason From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiscontinuedForUnspecifiedReason¶
Procedure discontinued due to incorrect patient or procedure step selected from modality worklist From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IncorrectWorklistEntrySelected¶
Patient condition prevented continuation of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientConditionPreventedContinuing¶
Procedure step is discontinued to change to other equipment or modality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentChange¶
A movement of the patient affecting test quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientMovement¶
An error of the operator affecting test quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OperatorError¶
One or more of the objects is malformed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectsIncorrectlyFormatted¶
Receiving System is unable to accept the object type From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectTypesNotSupported¶
One or more objects associated with the object set is missing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectSetIncomplete¶
The contents of the Media could not be accessed properly From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MediaFailure¶
Procedure discontinued due to necessary equipment, staff or other resource becoming (temporarily) unavailable to the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResourcePre_empted¶
Procedure discontinued due to necessary equipment, staff or other resource being inadequate to complete the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResourceInadequate¶
A new Procedure Step has been scheduled to replace the Discontinued Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiscontinuedProcedureStepRescheduled¶
It is recommended that a new Procedure Step be scheduled to replace the Discontinued Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiscontinuedProcedureStepReschedulingRecommended¶
Ventral structures of the diencephalon that cannot readily be distinguished on MR imaging, including the hypothalamus, mammillary body, subthalamic nuclei, substantia nigra, red nucleus, lateral geniculate nucleus, medial geniculate nucleus, zona incerta, cerebral peduncle, lenticular fasciculus, medial lemniscus, and optic tract. See http://neuromorphometrics.org:8080/Seg/html/se gmentation/ventral%20diencephalon.html From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VentralDiencephalon¶
Area(s) of reduced intensity on T1 weighted images relative to the surrounding white matter. These may be indicative of age-related or neurodegenerative white matter lesions, and may be co-located with areas of white matter T2 hyperintensity, but the concept is specifically confined to the MR appearance on T1 weighted images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WhiteMatterT1Hypointensity¶
Area(s) of increased intensity on T2 weighted images relative to the surrounding white matter. These may be indicative of age-related or neurodegenerative white matter lesions, and may be co-located with areas of white matter T1 hypointensity, but the concept is specifically confined to the MR appearance on T2 weighted images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WhiteMatterT2Hyperintensity¶
The dorsal component of the SLF originating from the medial and dorsal parietal cortex and ending in the dorsal and medial part of the frontal lobe. See Makris N, et al. “Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study.” Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuperiorLongitudinalFasciculusI¶
The major component of the SLF, derived from the caudal-inferior parietal region corresponding to the angular gyrus in the human and terminating within the dorsolateral frontal region. See Makris N, et al. “Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study.” Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuperiorLongitudinalFasciculusII¶
The ventral component of the SLF, originating from the supramarginal gyrus and terminating predominantly in the ventral premotor and prefrontal areas. See Makris N, et al. “Segmentation of Subcomponents within the Superior Longitudinal Fascicle in Humans: A Quantitative, In Vivo, DT-MRI Study.” Cerebral Cortex 15, no. 6 (June 1, 2005): 854-69. doi:10.1093/cercor/bhh186 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuperiorLongitudinalFasciculusIII¶
White matter that surrounds a lesion of interest; e.g. to identify the otherwise unclassified white matter that surrounds a tumor to be surgically resected From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerilesionalWhiteMatter¶
Signal intensity of a Spin tagging Perfusion MR image. Spin tagging is a technique for the measurement of blood perfusion, based on magnetically labeled arterial blood water as an endogenous tracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpinTaggingPerfusionMRSignalIntensity¶
Signal intensity of a Contrast Agent Angio MR image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastAgentAngioMRSignalIntensity¶
Signal intensity of a Time-of-flight (TOF) MR image. Time-of-flight (TOF) is based on the phenomenon of flow-related enhancement of spins entering into an imaging slice. As a result of being unsaturated, these spins give more signal that surrounding stationary spins From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeOfFlightAngioMRSignalIntensity¶
Signal intensity of a Proton Density Weighted MR image. All MR images have intensity proportional to proton density. Images with very little T1 or T2 weighting are called ‘PD-weighted’ From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProtonDensityWeightedMRSignalIntensity¶
Signal intensity of T1 Weighted MR image. A T1 Weighted MR image is created typically by using short TE and TR times From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1WeightedMRSignalIntensity¶
Signal intensity of a T2 Weighted MR image. T2 Weighted image contrast state is approached by imaging with a TR long compared to tissue T1 (to reduce T1 contribution to image contrast) and a TE between the longest and shortest tissue T2s of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2WeightedMRSignalIntensity¶
Signal intensity of a T2* Weighted MR image. The T2* phenomenon results from molecular interactions (spin spin relaxation) and local magnetic field non- uniformities, which cause the protons to precess at slightly different frequencies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2_WeightedMRSignalIntensity¶
Signal intensity of a Field Map MR image. A Field Map MR image provides a direct measure of the B 0 inhomogeneity at each point in the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FieldMapMRSignalIntensity¶
Coefficient reflecting the fractional anisotropy of the tissues, derived from a diffusion weighted MR image. Fractional anisotropy is proportional to the square root of the variance of the Eigen values divided by the square root of the sum of the squares of the Eigen values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FractionalAnisotropy¶
Coefficient reflecting the relative anisotropy of the tissues, derived from a diffusion weighted MR image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeAnisotropy¶
Dxx Component of the diffusion tensor, quantifying the molecular mobility along the X axis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDxxComponent¶
Dxy Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Y directions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDxyComponent¶
Dxz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the X and Z directions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDxzComponent¶
Dyy Component of the diffusion tensor, quantifying the molecular mobility along the Y axis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDyyComponent¶
Dyz Component of the diffusion tensor, quantifying the correlation of molecular displacements in the Y and Z directions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDyzComponent¶
Dzz Component of the diffusion tensor, quantifying the molecular mobility along the Z axis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumetricDiffusionDzzComponent¶
Signal intensity of a T1 Weighted Dynamic Contrast Enhanced MR image. A T1 Weighted Dynamic Contrast Enhanced MR image reflects the dynamics of diffusion of the exogenous contrast media from the blood pool into the extra vascular extracellular space (EES) of the brain at a rate determined by the blood flow to the tissue, the permeability of the Brain Blood Barrier (BBB), and the surface area of the perfusing vessels From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1WeightedDynamicContrastEnhancedMRSignalIntensity¶
Signal intensity of a T2 Weighted Dynamic Contrast Enhanced MR image. A T2 Weighted Dynamic Contrast Enhanced MR image reflects the T2 of tissue decrease as the Gd contrast agent bolus passes through the brain From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2WeightedDynamicContrastEnhancedMRSignalIntensity¶
Signal intensity of a T2* Weighted Dynamic Contrast Enhanced MR image. A T2* Weighted Dynamic Contrast Enhanced MR image reflects the T2* of tissue decrease as the Gd contrast agent bolus passes through the brain From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2_WeightedDynamicContrastEnhancedMRSignalIntensity¶
Signal intensity of a Blood Oxygenation Level image. BOLD imaging is sensitive to blood oxygenation (but also to cerebral blood flow and volume). This modality is essentially used for detecting brain activation (functional MR) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodOxygenationLevel¶
Accumulated decay event counts in a nuclear medicine projection image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NuclearMedicineProjectionActivity¶
Accumulated decay event counts in a Nuclear Medicine Tomographic image (including PET) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NuclearMedicineTomographicActivity¶
Spatial Displacement along axis X of a non-linear deformable spatial registration image. The X axis is defined in reference to the patient’s orientation, and is increasing to the left hand side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpatialDisplacementXComponent¶
Spatial Displacement along axis Y of a non-linear deformable spatial registration image. The Y axis is defined in reference to the patient’s orientation, and is increasing to the posterior side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpatialDisplacementYComponent¶
Spatial Displacement along axis Z of a non-linear deformable spatial registration image. The Z axis is defined in reference to the patient’s orientation, and is increasing toward the head of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpatialDisplacementZComponent¶
Measured resistance to the flow of blood; e.g. through the vasculature or through a heart value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemodynamicResistance¶
Measured resistance to the flow of blood; e.g. through the vasculature or through a heart value, normalized to a particular indexed scale From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndexedHemodynamicResistance¶
Velocity of tissue based on Doppler measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TissueVelocity¶
Velocity of blood flow based on Doppler measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlowVelocity¶
Statistical variance of blood velocity relative to mean From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlowVariance¶
Scalar value related to the elastic properties of the tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Elasticity¶
Scalar value related to the volume of blood perfusing into tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Perfusion¶
Speed of sound in tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpeedOfSound¶
Reduction in strength of ultrasound signal as the wave From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UltrasoundAttenuation¶
Red component of a true color image (RGB) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RGBRComponent¶
Green component of a true color image (RGB) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RGBGComponent¶
Blue component of a true color image (RGB) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RGBBComponent¶
Y (Luminance) component of a YBR FULL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRFULLYComponent¶
CB (Blue chrominance) component of a YBR FULL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRFULLCBComponent¶
CR (Red chrominance) component of a YBR FULL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRFULLCRComponent¶
Y (Luminance) component of a YBR PARTIAL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRPARTIALYComponent¶
CB (Blue chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRPARTIALCBComponent¶
CR (Red chrominance) component of a YBR PARTIAL image, as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRPARTIALCRComponent¶
Y (Luminance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRICTYComponent¶
CB (Blue chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRICTCBComponent¶
CR (Red chrominance) component of a YBR ICT image (Irreversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRICTCRComponent¶
Y (Luminance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRRCTYComponent¶
CB (Blue chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRRCTCBComponent¶
CR (Red chrominance) component of a YBR RCT image (Reversible Color Transform), as defined in JPEG 2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- YBRRCTCRComponent¶
The ability of a material to create an ultrasound return echo From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Echogenicity¶
Decrease in the number of photons in an X-Ray beam due to interactions with the atoms of a material substance. Attenuation is due primarily to two processes, absorption and scattering From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayAttenuation¶
Coefficient that describes the fraction of a beam of X-Rays or gamma rays that is absorbed or scattered per unit thickness of the absorber. This value basically accounts for the number of atoms in a cubic cm volume of material and the probability of a photon being scattered or absorbed from the nucleus or an electron of one of these atoms From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayAttenuationCoefficient¶
Signal intensity of an MR image, not otherwise specified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MRSignalIntensity¶
Binary value denoting that the segmented property is present From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BinarySegmentation¶
Probability, defined as a percentage, that the segmented property occupies the spatial area defined by the voxel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FractionalProbabilisticSegmentation¶
Percentage of the voxel area occupied by the segmented property From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FractionalOccupancySegmentation¶
Spatial dimension, denoting a linear displacement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LinearDisplacement¶
Dimension denoting the energy (frequency or wavelength) of photons From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhotonEnergy¶
Dimension used to sequence events, to compare the duration of events and the intervals between events From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Time¶
Spatial dimension, denoting an angle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Angle¶
A spatial dimension axis running along a line between the patient’s left and right side From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Left_RightAxis¶
A spatial dimension axis running along a line between the patient’s head and foot From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Head_FootAxis¶
A spatial dimension axis running along a line between the patient’s anterior and posterior sides From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Anterior_PosteriorAxis¶
A spatial dimension axis running along a line between the apex and base of an organ, object, or chamber From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Apex_BaseAxis¶
A spatial dimension axis running along a line between the anterior and inferior sides of an organ, object, or chamber From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Anterior_InferiorAxis¶
A spatial dimension axis running along a line between the septum and wall of a chamber From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Septum_WallAxis¶
Orientation of a spatial dimension where increasing values run from the right to the left side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightToLeft¶
Orientation of a spatial dimension where increasing values run from the left to the right side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftToRight¶
Orientation of a spatial dimension where increasing values run from the head to the foot of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HeadToFoot¶
Orientation of a spatial dimension where increasing values run from the foot to the head of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FootToHead¶
Orientation of a spatial dimension where increasing values run from the anterior to the posterior side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnteriorToPosterior¶
Orientation of a spatial dimension where increasing values run from the posterior to the anterior side of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorToAnterior¶
Orientation of a spatial dimension where increasing values run from the apex to the base From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApexToBase¶
Orientation of a spatial dimension where increasing values run from the base to the apex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaseToApex¶
Orientation of a spatial dimension where increasing values run from the anterior to the inferior From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnteriorToInferior¶
Orientation of a spatial dimension where increasing values run from the inferior to the anterior From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InferiorToAnterior¶
Orientation of a spatial dimension where increasing values run from the septum of a chamber to the opposite wall From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeptumToWall¶
Orientation of a spatial dimension where increasing values run from the opposite wall to the septum of a chamber From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallToSeptum¶
The x coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagePosition_Patient_X¶
The y coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagePosition_Patient_Y¶
The z coordinate of the upper left hand corner (center of the first voxel transmitted) of the image, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagePosition_Patient_Z¶
The x value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_RowX¶
The y value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_RowY¶
The z value of the first row direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_RowZ¶
The x value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_ColumnX¶
The y value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_ColumnY¶
The z value of the first column direction cosine with respect to the patient, with respect to the patient-based coordinate system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageOrientation_Patient_ColumnZ¶
Number of rows in the pixel data of the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelDataRows¶
Number of columns in the pixel data of the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelDataColumns¶
The name assigned by a manufacturer to a specific software algorithm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlgorithmName¶
The input parameters used by a manufacturer to configure the behavior of a specific software algorithm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlgorithmParameters¶
The software version identifier assigned by a manufacturer to a specific software algorithm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlgorithmVersion¶
The type of correlation applied to detection results; e.g. temporal, spatial From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnalysisPerformed¶
Assignment of intermediate or overall interpretation results to a general category From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AssessmentCategory¶
Assessment of annotating tissues in breast; generally including fatty, mixed or dense From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastComposition¶
Purpose of reference for an SCOORD content item that is an outline of the breast that includes the pectoral muscle tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastOutlineIncludingPectoralMuscleTissue¶
The type of distribution associated with detected calcifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationDistribution¶
Identification of the morphology of detected calcifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationType¶
Purpose of reference for an SCOORD content item that identifies the central point of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Center¶
The likelihood that the feature analyzed is in fact the type of feature identified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CertaintyOfFeature¶
The likelihood that the finding detected is in fact the type of finding identified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CertaintyOfFinding¶
The certainty that a device places on an impression, where 0 equals no certainty and 100 equals certainty From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CertaintyOfImpression¶
A location identifier based on clock-face numbering or anatomic sub-region From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClockfaceOrRegion¶
An item that is an inferred correlation relating two or more individual findings or features From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompositeFeature¶
The inferred relationship between the findings or features making up a composite feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompositeType¶
General assessment of whether or not CAD processing was successful, and whether any findings resulted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CADProcessingAndFindingsSummary¶
The date the data creation started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContentDate¶
The time the data creation started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContentTime¶
A location identifier based on a feature’s inferred distance from the surface of the associated anatomy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Depth¶
A textual description of the change that occurred over time in a qualitative characteristic of a feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DescriptionOfChange¶
The type of finding sought after by a specific algorithm applied to one image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DetectionPerformed¶
A general change that occurred within an imaged area between a prior imaging procedure and the current imaging procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferentialDiagnosis_Impression¶
A group of analysis algorithms that were attempted, but failed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FailedAnalyses¶
A group of detection algorithms that were attempted, but failed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FailedDetections¶
For projection radiography, the horizontal physical distance measured at the front plane of an Image Receptor housing between the center of each pixel. For tomographic images, the horizontal physical distance in the patient between the center of each pixel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HorizontalPixelSpacing¶
Laterality of (possibly paired) body part contained in an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageLaterality¶
A container that references all image data used as evidence to produce a report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageLibrary¶
A numeric value in the range 0 to 100, inclusive, where 0 is worst quality and 100 is best quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageQualityRating¶
Purpose of reference for an SCOORD content item that identifies a specific region of interest within an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageRegion¶
The projection of the anatomic region of interest on an image receptor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageView¶
Modifier for Image View From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageViewModifier¶
Free-form text describing the overall or an individual impression From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImpressionDescription¶
A container for a group of related results from interpretation of one or more images and associated clinical information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndividualImpression_Recommendation¶
The X-Ray attenuation of a lesion relative to the expected attenuation of an equal volume of fibroglandular breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionDensity¶
A structured report containing the results of computer-aided detection or diagnosis applied to breast imaging and associated clinical information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MammographyCADReport¶
The characteristic of the boundary, edges or border of a detected lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Margins¶
The quantity of calcifications detected within an identified group or cluster From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfCalcifications¶
A non-lesion object identified within one or more images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectType¶
Purpose of reference for a COMPOSITE content item that identifies it as the original source of evidence for another content item in the report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OriginalSource¶
Purpose of reference for an SCOORD content item that identifies the outline or bounding region of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Outline¶
The inferred type of disease associated with an identified feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pathology¶
The patient orientation relative to the image plane, specified by a value that designates the anatomical direction of the positive column axis (top to bottom) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientOrientationColumn¶
The patient orientation relative to the image plane, specified by a value that designates the anatomical direction of the positive row axis (left to right) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientOrientationRow¶
Purpose of reference for an SCOORD content item that is an outline of the pectoral muscle tissue only From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PectoralMuscleOutline¶
Percent of breast area that is mammographically dense, excluding pectoralis muscle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercentFibroglandularTissue¶
The likelihood that an identified finding or feature is cancerous From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProbabilityOfCancer¶
A location identifier based on the division of an area into four regions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuadrantLocation¶
A qualitative characteristic of a feature that has changed over time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualitativeDifference¶
The effect of the quality of an image on its usability From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityAssessment¶
The quality control standard used to make a quality assessment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityControlStandard¶
A specific quality related deficiency detected within an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityFinding¶
Recommended type of follow-up to an imaging procedure, based on interpreted results From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecommendedFollow_up¶
Recommended follow-up date to an imaging procedure, based on interpreted results From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecommendedFollow_upDate¶
Recommended follow-up interval to an imaging procedure, based on interpreted results From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecommendedFollow_upInterval¶
The recommendation of the producer of a content item regarding presentation of the content item by recipients of the report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RenderingIntent¶
An indication of how widespread the detection of a feature is within the analyzed image data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScopeOfFeature¶
A textual description of the contents of a selected region identified within an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SelectedRegionDescription¶
An item that was detected on one image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleImageFinding¶
Date on which the acquisition of the study information was started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StudyDate¶
Time at which the acquisition of the study information was started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StudyTime¶
A group of analysis algorithms that were attempted and completed successfully From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuccessfulAnalyses¶
A group of detection algorithms that were attempted and completed successfully From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuccessfulDetections¶
An overall indication of whether the CAD detection algorithms applied were completed successfully From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SummaryOfDetections¶
An overall indication of whether the CAD analysis algorithms applied were completed successfully From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SummaryOfAnalyses¶
For projection radiography, the vertical physical distance measured at the front plane of an Image Receptor housing between the center of each pixel. For tomographic images, the vertical physical distance in the patient between the center of each pixel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VerticalPixelSpacing¶
A radiographic projection that has been with the patient lying on a table with the X-Ray source on one side of the table and the detector on the other; e.g. may describe a cross-table cervical spine, chest or pelvis X-Ray image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Crosstable¶
One of a number of discrete points on the Receiver-Operator Characteristics (ROC) curve that reflects the expected sensitivity and specificity of a CAD algorithm, where zero indicates the highest specificity, lowest sensitivity operating point. The value should not exceed the Maximum CAD Operating Point From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CADOperatingPoint¶
The maximum value of CAD Operating Point for the specific CAD algorithm used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumCADOperatingPoint¶
The intended interpretation of a CAD Operating Point From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CADOperatingPointDescription¶
The number of false CAD markers per image. Correlates to inverse of Image Specificity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FalseMarkersPerImage¶
The number of false markers per collection of images that are CAD processed as a group. Correlates to inverse of Case Specificity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FalseMarkersPerCase¶
The percentage of cancers that should be detected by a CAD algorithm where CAD marks the cancers in at least one view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CaseSensitivity¶
The percentage of cancers that should be detected by a CAD algorithm where CAD marks the cancers in each view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionSensitivity¶
The percentage of cases (collections of images CAD processed as a group) without cancer that have no CAD findings whatsoever. Correlates to inverse of False Markers per Case From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CaseSpecificity¶
The percentage of images without cancer that have no CAD findings whatsoever. Correlates to inverse of False Markers per Image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageSpecificity¶
The CAD operating point that is recommended for initial display by the creator of the structured report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecommendedCADOperatingPoint¶
A list of CAD operating points including their corresponding characteristics From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CADOperatingPointTable¶
A specific area of interest noted within an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SelectedRegion¶
The surface shape of all or a portion of breast related anatomy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastGeometry¶
Image quality incorporates the following clinical image evaluation parameters: assessment of positioning, compression, artifacts, exposure, contrast, sharpness, and labeling From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageQuality¶
A finding or feature that is identified as a non-anatomic foreign object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_lesion¶
A space-occupying lesion identified in a single image or projection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Density¶
A single identified calcification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndividualCalcification¶
Multiple calcifications identified as occupying a small area of tissue (less than 2 cc) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationCluster¶
Straightening or thickening of Cooper’s ligaments From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cooper_sLigamentChanges¶
An abnormality noted at imaging within the dermis of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassInTheSkin¶
An abnormality noted at imaging on the epidermis of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassOnTheSkin¶
An assessment category to indicate that images have been acquired to assess marker placement following a breast interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PostProcedureMammogramsForMarkerPlacement¶
An indication that the patient should seek post procedural follow-up directives from a clinical health care provider From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Follow_upPostBiopsyAsDirectedByClinician¶
A recommendation on a patient with known cancer to take steps appropriate to the diagnosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KnownBiopsyProvenMalignancy_TakeAppropriateAction¶
Positioning of a radiopaque marker From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MarkerPlacement¶
Patient has previous diagnosis of breast cancer resulting in mastectomy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonalHistoryOfBreastCancerWithMastectomy¶
Patient has had biopsy containing proven malignancy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KnownBiopsyProvenMalignancy¶
Patient has a finding of mass reported on a prior imaging exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageDetectedMass¶
A breast imaging procedure performed on a specific area of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Targeted¶
A breast imaging procedure performed on the entire breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Survey¶
A cluster of tiny anechoic foci each smaller than 2-3 mm in diameter with thin (less than 0.5 mm) intervening septations and no discrete solid components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClusteredMicrocysts¶
A fluid filled mass most commonly characterized by homogeneous low-level internal echoes on ultrasound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComplicatedCyst¶
Views not inclusive of MLO and CC (BI-RADS®) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdditionalProjections¶
A spot or coned down compression of the breast providing a reduction in the thickness and a magnification of the localized area of interest and improved separation of breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpotMagnificationView_s_¶
Use of sound waves to visualize muscles, tendons, and many internal organs, to capture their size, structure and any pathological lesions with real time tomographic images. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ultrasound¶
Obtain previous mammography studies to compare to present study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OldFilmsForComparison¶
A medical procedure used for the sampling of mammary duct tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ductography¶
Follow up study at 12 months for women 40 years of age having a prior negative study and no mitigating risk factors for breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalIntervalFollow_up¶
Any decision to perform tissue acquisition should be based on clinical assessment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnyDecisionToBiopsyShouldBeBasedOnClinicalAssessment¶
Follow-up at short interval (1-11 months) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Follow_upAtShortInterval_1_11Months_¶
Tissue acquisition should be considered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiopsyShouldBeConsidered¶
Breast tissue acquisition following the identification of an area of concern with the placement of a needle or needle-wire assembly From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeedleLocalizationAndBiopsy¶
Pathologic analysis of breast tissue and lesions using core tissue samples From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistologyUsingCoreBiopsy¶
Lesions that do not have the characteristic morphologies of breast cancer but have a definite probability of being malignant. There is a sufficient concern to urge a biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuggestiveOfMalignancy_TakeAppropriateAction¶
Cellular analysis of specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CytologicAnalysis¶
Tissue acquisition should be strongly considered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiopsyShouldBeStronglyConsidered¶
Lesions have a high probability of being cancer, which require additional action From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HighlySuggestiveOfMalignancy_TakeAppropriateAction¶
The producer of a report intends for a recipient of the report to present or display the associated content item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PresentationRequired_RenderingDeviceIsExpectedToPresent¶
The producer of a report considers the presentation or display of the associated content item by a recipient to be optional From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PresentationOptional_RenderingDeviceMayPresent¶
The producer of a report intends for a recipient of the report NOT to present or display the associated content item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotForPresentation_RenderingDeviceExpectedNotToPresent¶
The associated content items are identified as being the same finding or feature at different points in time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetContentItemsAreRelatedTemporally¶
The associated content items are identified as being the same finding or feature on different projections taken at the same point in time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetContentItemsAreRelatedSpatially¶
The associated content items are identified as being related side-to-side From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetContentItemsAreRelatedContra_laterally¶
There is one image in the interpreted data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FeatureDetectedOnTheOnlyImage¶
There is more than one image of the same modality in the interpreted data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FeatureDetectedOnOnlyOneOfTheImages¶
There is more than one image of the same modality in the interpreted data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FeatureDetectedOnMultipleImages¶
The interpreted data set contains images from multiple modalities From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FeatureDetectedOnImagesFromMultipleModalities¶
The fibrous tissue replacing normal tissues destroyed by disease or injury From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScarTissue¶
A medical appliance used for localization of non palpable breast lesions to insure that the proper area is removed in a surgical biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- JWire¶
A medical appliance used for regulating cardiac rhythms From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pacemaker¶
A compression device used for obtaining mammographic images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Paddle¶
A device used for restricting an X-Ray beam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Collimator¶
An area designated on a radiographic film for facility and patient ID information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IDPlate¶
Site specific markers From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherMarker¶
The value of the concept is not specified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Unspecified¶
Image quality deficiency according to MQSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerIsMissing¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerDoesNotHaveBothViewAndLaterality¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerDoesNotHaveApprovedCodes¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerIsNotNearTheAxilla¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerOverlapsBreastTissue¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerIsPartiallyObscured¶
Image quality deficiency From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerIsIncorrect¶
Image quality deficiency From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ViewAndLateralityMarkerIsOffImage¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashIsNotNearEdgeOfFilm¶
Image quality deficiency according to MQSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashIsIlligible_DoesNotFit_OrIsLopsided¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludePatientNameAndAdditionalPatientId¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludeDateOfExamination¶
Image quality deficiency according to MQSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludeFacilityNameAndLocation¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludeTechnologistIdentification¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludeCassette_screen_detectorIdentification¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlashDoesn_tIncludeMammographyUnitIdentification¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateStickerIsMissing¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TechnicalFactorsMissing¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CollimationTooCloseToBreast¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InadequateCompression¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MLOInsufficientPectoralMuscle¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MLONoFatIsVisualizedPosteriorToFibroglandularTissues¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MLOPoorSeparationOfDeepAndSuperficialBreastTissues¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MLOEvidenceOfMotionBlur¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MLOInframammaryFoldIsNotOpen¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CCNotAllMedialTissueVisualized¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CCNippleNotCenteredOnImage¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CCPosteriorNippleLineDoesNotMeasureWithin1CmOfMLO¶
Image quality deficiency From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NippleNotInProfile¶
Image quality deficiency according to MQCM From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InsufficientImplantDisplacementIncorrect¶
Signals that do not faithfully reproduce actual anatomic structures because of distortion or of addition or deletion of information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageArtifact_s_¶
Feature(s) arising from the acquisition unit’s anti-scatter grid mechanism. For two-dimensional systems, such features include those of mechanically damaged or incorrectly positioned grids. For moving or Bucky grids, artifacts may result from intentional grid motion that is inadequate in duration or velocity uniformity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GridArtifact_s_¶
Inadequate arrangement of the anatomy of interest with respect to the X-Ray field and image detector sensitive area. Examples: 1) positioning is “cutoff” when the projection of anatomy of interest falls outside the sensitive area of the detector; 2) “cone cut”, in which the X-Ray field does not adequately cover the anatomy of interest; 3) detector’s sensitive surface is too small to cover the projection of the anatomy of interest; 4) improper angular orientation or “rotation” of anatomy of interest with respect to the X-Ray source, or detector; 5) projection of other anatomy or clothing over the anatomy of interest in the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Positioning¶
Unacceptable image blur resulting from motion of the anatomy of interest during exposure or the inadequately compensated motion of X-Ray source with respect to the image detector during exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MotionBlur¶
Inadequate number of quanta reached the detector during exposure. Reasons for under exposed images include low kVp, low mAs product, excess Source Image Distance. Under exposed images have inadequate signal and higher noise in the areas of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnderExposed¶
An excess number of quanta reached the detector during exposure. Reasons for over exposed images include high kVp, high mAs product, short Source Image Distance. Over exposed images have high signal and lower noise in the areas of interest. Over exposed area may demonstrate lack of contrast from over saturation of the detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OverExposed¶
No evidence of a patient exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoImage¶
Superposed features or flaws of the detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DetectorArtifact_s_¶
Features or discontinuities arising from causes other than the anti-scatter grid and image detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Artifact_s_OtherThanGridOrDetectorArtifact¶
Failure of the device to operate according to mechanical design specifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MechanicalFailure¶
Failure of a device to operate according to electrical design specifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ElectricalFailure¶
Attributable to software used in generation or handling of image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SoftwareFailure¶
Images processed inappropriately, not following appropriate protocol From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InappropriateImageProcessing¶
Failure that is not mechanical or electrical or otherwise described From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherFailure¶
Unidentified or unknown cause of failure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnknownFailure¶
The attempted process was completely successful From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Succeeded¶
The attempted process succeeded in some ways, but failed in others From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PartiallySucceeded¶
The attempted process completely failed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Failed¶
No process was performed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotAttempted¶
Analysis of a related group of findings or features detected during image data inspection, to produce a summary impression and/or recommendation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndividualImpression_RecommendationAnalysis¶
Analysis of all groups of findings or features, to produce a single impression and/or recommendation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OverallImpression_RecommendationAnalysis¶
The usability of an image for diagnostic interpretation or CAD, based on a quality control standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Unusable_QualityRendersImageUnusable¶
The usability of an image for diagnostic interpretation or CAD, based on a quality control standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Usable_DoesNotMeetTheQualityControlStandard¶
The usability of an image for diagnostic interpretation or CAD, based on a quality control standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Usable_MeetsTheQualityControlStandard¶
An image quality control standard specified by the American College of Radiology From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MammographyQualityControlManual1999_ACR¶
An image quality control standard in the US Code of Federal Regulations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Title21CFRSection900_SubpartB¶
An image quality control standard specified or adopted by the institution responsible for the document From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InstitutionallyDefinedQualityControlStandard¶
No findings resulted upon successful completion of all attempted computer- aided detection and/or analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AllAlgorithmsSucceeded_WithoutFindings¶
One or more findings resulted upon successful completion of all attempted computer-aided detection and/or analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AllAlgorithmsSucceeded_WithFindings¶
No findings resulted from the attempted computer-aided detection and/or analysis, but one or more failures occurred in the process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotAllAlgorithmsSucceeded_WithoutFindings¶
One or more findings resulted from the attempted computer-aided detection and/or analysis, but one or more failures occurred in the process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotAllAlgorithmsSucceeded_WithFindings¶
All of the attempted computer-aided detection and/or analysis failed, so there could be no findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoAlgorithmsSucceeded_WithoutFindings¶
A benign tumor having glandular characteristics but composed of fat, with the presence of normal mammary ducts From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Adenolipoma¶
Hyperplasia is also known as epithelial hyperplasia or proliferative breast disease. It’s an overgrowth of the cells that line the ducts or the lobules. Based on how the cells look under a microscope, the hyperplasia is called either ductal hyperplasia (also called duct epithelial hyperplasia) or lobular hyperplasia. Based on the pattern of the cells, hyperplasia may be called usual or atypical. In usual hyperplasia, the pattern of cells is very close to normal. Atypical hyperplasia (or hyperplasia with atypia) is a term used when the cells are more distorted. FROM: http://www.cancer.org/healthy/findcancerearly/womenshealth/non- cancerousbreastconditions/non-cancerous-breast-conditions-hyperplasia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DuctalHyperplasia¶
Neoplasms composed of myoepithelial cells From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Adenomyoepithelioma¶
Axillary node that is normal in appearance with no associated pathology From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalAxillaryNode¶
Axillary node containing calcifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AxillaryNodeWithCalcifications¶
Excessive proliferation of normal tissue arrangement of the axillary node From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AxillaryNodeHyperplasia¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AsynchronousInvolution¶
Cyst with benign morphology containing blood From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BenignCystWithBlood¶
Calcifications having typically benign morphology. They are not of intermediate or high probability of concern for malignancy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BenignCalcifications¶
Growing within a cystic adenoma, filling the cavity with a mass of branching epithelial processes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntracysticPapilloma¶
Adenoma located in mammary duct, present as discrete sclerotic nodules, solitary or multiple From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DuctalAdenoma¶
The occurrence of fibrous tumor-forming stromal proliferation in patients with diabetes mellitus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiabeticFibrousMastopathy¶
A deep seated firm tumor frequently occurring on the chest consisting of collagenous tissue that infiltrates surround muscle; frequently recurs but does not metastasize From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExtraAbdominalDesmoid¶
A cyst formed of a mass of epithelial cells, as a result of trauma has been pushed beneath the epidermis. The cyst is lined with squamous epithelium and contains concentric layers or keratin From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EpidermalInclusionCyst¶
Excessive proliferation of fibroadenoma tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FibroadenomatoidHyperplasia¶
A lipoma with an abundant stroma of fibrous tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fibroadenolipoma¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForeignBody_reaction_¶
Retention cyst caused by occlusion of a lactiferous duct From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Galactocele¶
A congenital anomaly that leads to a proliferation of blood vessels leading to a mass that resembles a neoplasm, not located in parenchymal areas but subcutaneous From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hemangioma_Nonparenchymal_Subcutaneous¶
Hyperplasia is also known as epithelial hyperplasia or proliferative breast disease. It’s an overgrowth of the cells that line the ducts or the lobules. Based on how the cells look under a microscope, the hyperplasia is called either ductal hyperplasia (also called duct epithelial hyperplasia) or lobular hyperplasia. FROM: http://www.cancer.org/healthy/findcancerearly/womenshealth/non- cancerousbreastconditions/non-cancerous-breast-conditions-hyperplasia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hyperplasia_Usual¶
A form of fibrocystic disease in young woman with florid and sclerosing adenosis that microscopically may suggest carcinoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- JuvenilePapillomatosis¶
Enlarging masses during lactation. A circumscribed benign tumor composed primarily of glandular structures with scanty stroma, with prominent secretory changes in the duct From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LactatingAdenoma¶
Changes related to the process of lactation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LactationalChange¶
A papilloma pertaining to large mammary duct From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LargeDuctPapilloma¶
Solitary or multiple tumors of muscles and fibrous tissues, or tumors composed of myofibroblasts From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Myofibroblastoma¶
Irregular clusters of small tubules are present in adipose or fibrous tissue, resembling tubular carcinoma but lacking stromal fibroblastic proliferation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MicroglandularAdenosis¶
Papilloma typically involving an aggregate of adjacent ducts in the periphery of the breast, likely representing involvement of several foci of one or two duct systems From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultipleIntraductalPapillomas¶
No abnormality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoAbnormality¶
Normal breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalBreastTissue¶
Condition in which there are tumors of various sizes on peripheral nerves. They may be neuromas or fibromas From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Neurofibromatosis¶
A cyst resulting from the loss of the epithelial lining of a sebaceous dermoid or lacteal cyst From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OilCyst_fatNecrosisCyst_¶
Breast tissue with characteristics of a benign nature, following breast reduction surgery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PostReductionMammoplasty¶
A benign stromal lesion composed of intermixed stromal and epithelial elements. The lobular and duct structures of the breast parenchyma are separated by an increased amount of stroma, non specific proliferative epithelial changes include hyperplasia of duct and lobular epithelium often with accentuation of myoepithelial cells and aprocine metaplasia with or without cyst formation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PseudoangiomatousStromalHyperplasia¶
An nonencapsulated stellate lesion consisting of a fibroelastic core and radiating bands of fibrous connective tissue containing lobules manifesting adenosis and ducts with papillary or diffuse intraductal hyperplasia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadialScar¶
Prominent interductal fibrosis of the terminal ductules From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SclerosingAdenosis¶
Nodular inflammatory lesions due to the presence of silicone in the breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SiliconeGranuloma¶
The morphologic status of the nipple From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NippleCharacteristic¶
Spontaneous excessive proliferation of breast tissue, usually found in younger women From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VirginalHyperplasia¶
Papilloma(s) pertaining the peripheral ducts From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeripheralDuctPapillomas¶
Axillary node with lymphoid tissue neoplasm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AxillaryNodeWithLymphoma¶
Metastatic disease to the axillary node From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AxillaryNodalMetastases¶
A malignant neoplasm occurring most often in breast and skin, believed to originate from endothelial cells of blood vessels, microscopically composed of closely packed round or spindle shaped cells, some of which line small spaces resembling vascular clefts From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Angiosarcoma¶
Histological changes to the vascular system related to an invasive process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVessel_vascular_Invasion¶
Carcinoma of the breast found in patients less than 20 years of age From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarcinomaInChildren¶
A carcinoma found in supernumerary breasts and aberrant breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarcinomaInEctopicBreast¶
A carcinoma that synthesizes substances, including hormones, not considered to be normal products of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarcinomaWithEndocrineDifferentiation¶
A basal cell carcinoma that arises in the nipple of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BasalCellCarcinomaOfNipple¶
Metaplastic carcinoma is cancer that begins in cells that have changed into another cell type (for example, a squamous cell of the esophagus changing to resemble a cell of the stomach). In some cases, metaplastic changes alone may mean there is an increased chance of cancer developing at the site. Metaplastic carcinoma is a relatively uncommon type of cancer with treatment generally similar to that of invasive ductal carcinoma of no special type.[1] FROM: https://en.wikipedia.org/wiki/Metaplastic_carcinoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarcinomaWithMetaplasia¶
Tissue changes to bones and cartilage From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CartilaginousAndOsseousChange¶
Carcinoma of the breast presenting during pregnancy or lactation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarcinomaInPregnancyAndLactation¶
A malignant neoplasm that contains elements of carcinoma and sarcoma, so extensively intermixed as to indicate neoplasia of epithelial and mesenchymal tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Carcinosarcoma¶
Comedocarcinoma of a duct with areas of necrotic tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntraductalComedocarcinomaWithNecrosis¶
A non-invasive carcinoma restricted to the glandular lumen characterized by less aggressive malignant cytologic features and behavior From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntraductalCarcinoma_LowGrade¶
Papillary and micropapillary Ductal Carcinoma In Situ (DCIS): the cancer cells arrange themselves in a fern-like pattern within the affected breast ducts; micropapillary DCIS cells are smaller than papillary DCIS cells. FROM: http://www.imaginis.com/breast-cancer-diagnosis/ductal-carcinoma-in-situ- dcis-3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntraductalCarcinomaMicro_papillary¶
A malignant neoplasm characterized by the formation of numerous, irregular, finger-like projections of fibrous stroma that is covered with a surface layer of neoplastic epithelial cells found in a cyst From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntracysticPapillaryCarcinoma¶
Carcinoma with both characteristics of localized and spreading disease From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InvasiveAndIn_situCarcinoma¶
Invasive lobular carcinoma is a type of breast cancer that begins in the milk- producing glands (lobules) of the breast. Invasive cancer means the cancer cells have broken out of the lobule where they began and have the potential to spread to the lymph nodes and other areas of the body. Invasive lobular carcinoma typically doesn’t form a lump, which is common in breast cancer. Instead, there is a change in the breast that feels like a thickening or fullness in one part of the breast and is different from the surrounding breast tissue. FROM: http://www.mayoclinic.org/diseases-conditions/invasive- lobular-carcinoma/basics/definition/con-20033968 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InvasiveLobularCarcinoma¶
Mammary infiltrates as a secondary manifestation in patients with established leukemia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeukemicInfiltration¶
Histological changes to the lymphatic system related to an invasive process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LympathicVesselInvasion¶
A heterogeneous group of neoplasms arising in the reticuloendoethelial and lymphatic systems From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Lymphoma¶
A small carcinoma, either asymptomatic or giving rise to metastases without symptoms due to the primary carcinoma presenting with metastatic disease in the axillary lymph nodes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OccultCarcinomaPresentingWithAxillaryLymphNodeMetastases¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a non-mammary malignant neoplasm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticCancerToTheBreast¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the colon From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticCancerToTheBreastFromTheColon¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the lung From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticCancerToTheBreastFromTheLung¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a melanoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticMelanomaToTheBreast¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a neoplasm in the ovary From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticCancerToTheBreastFromTheOvary¶
A malignant lesion in the breast with morphologic patterns not typical of breast carcinoma arising from a sarcoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticSarcomaToTheBreast¶
Multiple foci of non-invasive carcinoma restricted to the glandular lumen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultifocalIntraductalCarcinoma¶
A malignant lesion in an axillary node arising from a non-axillary neoplasm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastaticDiseaseToAxillaryNode¶
Pleomorphic undifferentiated sarcoma (abbreviated PUS), also undifferentiated pleomorphic sarcoma and previously malignant fibrous histiocytoma (abbreviated MFH), is a type of soft tissue sarcoma. FROM: https://en.wikipedia.org/wiki/Pleomorphic_undifferentiated_sarcoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MalignantFibrousHistiocytoma¶
Multiple sites of ductal carcinoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultifocalInvasiveDuctalCarcinoma¶
A malignant lesion in a intramammary lymph node arising from a non- intramammary lymph node neoplasm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetastasisToAnIntramammaryLymphNode¶
A malignant melanoma of the skin that arises in the nipple of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MalignantMelanomaOfNipple¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeoplasmOfTheMammarySkin¶
Papillary and micropapillary Ductal Carcinoma In Situ (DCIS): the cancer cells arrange themselves in a fern-like pattern within the affected breast ducts; micropapillary DCIS cells are smaller than papillary DCIS cells. FROM: http://www.imaginis.com/breast-cancer-diagnosis/ductal-carcinoma-in-situ- dcis-3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PapillaryCarcinomaIn_situ¶
Recurrent malignancy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecurrentMalignancy¶
Squamous cell carcinoma to the terminal portion of the alveolar From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SquamousCellCarcinomaOfTheNipple¶
A non-invasive carcinoma restricted to the glandular lumen characterized by more aggressive malignant cytologic features and behavior From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntraductalCarcinoma_HighGrade¶
Invasive tumor with cribriform pattern similar to cribriform DCIS. Low grade, cribriform appearance (well defined spaces formed by arches of cells) similar to cribriform DCIS but with larger cells, more cytoplasm and more vesicular nuclei: Tumor cells are small, often have apical snouts, mild/moderate nuclear pleomorphism; Also stromal invasion by islands of cells, often angulated; May have predominantly solid appearance; Associated with cribriform DCIS; Often mixed with tubular carcinoma. FROM: http://www.pathologyoutlines.com/topic/breastmalignantcribriform.html From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InvasiveCribriformCarcinoma¶
An indication that some or all of the margin of a lesion has sharp corners, often forming acute angles From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AngularMargins¶
Calcifications that vary in sizes and shapes and are usually smaller than0.5 mm in diameter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FinePleomorphicCalcification¶
Coarse calcifications that are 0.5 mm or greater in size From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Macrocalcifications¶
An indicator that calcifications are imbedded within a mass From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationsWithinAMass¶
An indicator that calcifications are imaged outside of a mass finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationsOutsideOfAMass¶
Tissue composition of the breast noted on sonography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastBackgroundEchotexture¶
Fat lobules and uniformly echogenic bands of supporting structures comprise the bulk of breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HomogeneousFatEchotexture¶
A uniformly echogenic layer of fibroglandular tissue is seen beneath a thin layer of subcutaneous fat From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HomogeneousFibroglandularEchotexture¶
The breast texture is characterized by multiple small areas of increased and decreased echogenicity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HeterogeneousEchotexture¶
Referential relationship of the finding to the imaging device as noted on sonography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Orientation¶
The long axis of a lesion parallels the skin line (“wider-than-tall” or in a horizontal orientation) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Parallel¶
The anterior-posterior or vertical dimension is greater than the transverse or horizontal dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotParallel¶
The lesion boundary describes the transition zone between themas and the surrounding tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionBoundary¶
The sharp demarcation between the lesion and surrounding tissue can be imperceptible or a distinct well-defined echogenic rim of any thickness From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbruptInterface¶
There is no sharp demarcation between the mass and the surrounding tissue, which is bridged by an echogenic transition zone From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EchogenicHalo¶
An imaging characteristic of resonance noted during sonography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EchoPattern¶
Without internal echoes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Anechoic¶
Having increased echogenicity relative to fat or equal to fibroglandular tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hyperechoic¶
Mass contains both anechoic and echogenic components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Complex¶
Defined relative to fat; masses are characterized by low-level echoes throughout; e.g. appearance of a complicated cyst or fibroadenoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hypoechoic¶
Having the same echogenicity as fat (a complicated cyst or fibroadenoma may be isoechoic or hypoechoic) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Isoechoic¶
The attenuation characteristics of a mass with respect to its acoustic transmission From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorAcousticFeatures¶
No posterior shadowing or enhancement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoPosteriorAcousticFeatures¶
Increased posterior echoes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorEnhancement¶
Decreased posterior echoes; edge shadows are excluded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorShadowing¶
More than one pattern of posterior attenuation, both shadowing and enhancement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CombinedPosteriorEnhancementAndShadowing¶
Sonographic appearance of adjacent structures relative to a mass finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IdentifiableEffectOnSurroundingTissues¶
Characterization of vascularization in region of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Vascularity¶
Vascularity not evident, such as on ultrasound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularityNotPresent¶
Vascularity not evaluated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularityNotAssessed¶
Vascularity on imaging is seen within a lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularityPresentInLesion¶
Vascularity on imaging is seen immediately adjacent to a lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularityPresentImmediatelyAdjacentToLesion¶
Vascularity on imaging is considered diffusely elevated within the surrounding breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiffuselyIncreasedVascularityInSurroundingTissue¶
Relationship of the new anomaly to other clinical or imaging anomalies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelationToOtherFindings¶
An indication that the current imaging finding relates to a finding from a clinical breast exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelatesToPhysicalExamFindings¶
An indication that the current imaging finding relates to a finding from a mammography exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelatesToMammographyFindings¶
An indication that the current imaging finding relates to a finding from a breast MRI exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelatesToMRIFindings¶
An indication that the current imaging finding relates to a finding from a breast ultrasound exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelatesToUltrasoundFindings¶
An indication that the current imaging finding relates to a finding from an imaging exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelatesToOtherImagingFindings¶
An indication that the current imaging finding has no relation to findings from any other imaging exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoCorrelationToOtherImagingFindings¶
An indication that the current imaging finding has no relation to any other clinical findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoCorrelationToClinicalFindings¶
Classification of the cancer as invasive, DCIS, or other From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MalignancyType¶
A malignancy that has spread beyond an area of focus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InvasiveBreastCarcinoma¶
A breast cancer with malignant pathology findings that are not classified as invasive or in situ From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherMalignancyType¶
A specific timeframe during menses From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MenstrualCyclePhase¶
In the first week of the menstrual cycle phase, that is, one week following menses From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EstimatedTimeframe¶
An event occurred less than 3 months ago From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeframeUncertain¶
Report title for the diagnostic report for one or more breast imaging or intervention procedures From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastImagingReport¶
Concept name for the description of why a procedure has been performed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReasonForProcedure¶
A finding during clinical examination (i.e., history and physical examination) such as pain, palpable mass or discharge From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClinicalFinding¶
First screening mammogram taken for patient that is used as a comparison baseline for further examinations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaselineScreeningMammogram¶
First mammogram taken for a patient without regard to whether it was for screening or a diagnostic procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FirstMammogramEver¶
Concept name for the material of which a breast prosthetic device is constructed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantType¶
A numeric count of findings classified as similar in nature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfSimilarFindings¶
Concept name for the status of a breast prosthetic device as noted by imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantFinding¶
Mammogram using traditional X-Ray film From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FilmScreenMammography¶
Mammogram using a digital image acquisition system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DigitalMammography¶
Referred for evaluation by a surgeon From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SurgicalConsult¶
Computer aided detection and/or computer aided diagnosis for mammography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MammographyCAD¶
Concept name for a text-based section of a report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NarrativeSummary¶
A title for a report section that summarizes all interpretation results for a report with one overriding assessment; e.g. benign or negative From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OverallAssessment¶
Concept name for a collection of supporting evidence for a report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SupplementaryData¶
Prior study indicates that additional imaging be performed to further evaluate a suspicious or questionable anatomic region From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdditionalEvaluationRequestedFromPriorStudy¶
The prior study recommended a follow-up breast imaging exam in 1 to 11 months (generally in 6 months) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Follow_upAtShortIntervalFromPriorStudy¶
Prior breast augmentation (breast enlargement) and is not presenting with any symptoms From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfBreastAugmentation_Asymptomatic¶
Review or second opinion made on an image performed outside of the facility From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReviewOfAnOutsideStudy¶
Additional breast imaging performed at the time of the patient’s screening mammogram From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdditionalEvaluationRequestedFromAbnormalScreeningExam¶
Patient has had previous benign breast biopsies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfBenignBreastBiopsy¶
Patient has had a prior surgery such as a lumpectomy or quadrantectomy to remove malignant breast tissue, but breast tissue remains From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonalHistoryOfBreastCancerWithBreastConservationTherapy¶
The results of a physical examination performed on the patient, possibly including the results of inspection, palpation, auscultation, or percussion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhysicalExaminationResults¶
The result of assessing the current imaging exam in comparison to previous imaging exams From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComparisonToPreviousFindings¶
An abnormality observed during ductography where the ductal system within the breast fills in an abnormal pattern. Ductography is an imaging exam in which a radio opaque contrast media is introduced into the ductal system of the breast through the nipple and images of the ductal system are obtained From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntraluminalFillingDefect¶
During ductography an observation of more than one filling abnormality within the breast ductal system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultipleFillingDefect¶
An abnormality observed during ductography where the ductal system within the breast terminates in an unusual fashion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbruptDuctTermination¶
Abnormal flowage of contrast media within the breast noted on ductography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Extravasation¶
An abnormality observed during ductography where the ductal system within the breast appears narrow From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DuctNarrowing¶
During ductography an observation of the contrast media filling a cyst within the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CystFill¶
The area and line within the anatomy through which a needle or instrument passes during an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InstrumentApproach¶
The line within the anatomy from the lower outer to the upper inner aspect; e.g. through which a needle or instrument passes in an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InferolateralToSuperomedial¶
The line within the anatomy from the lower inner to the upper outer aspect; e.g. through which a needle or instrument passes in an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InferomedialToSuperolateral¶
The line within the anatomy from the upper outer to the lower inner aspect; e.g. through which a needle or instrument passes in an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuperolateralToInferomedial¶
The line within the anatomy from the upper inner to the lower outer aspect; e.g. through which a needle or instrument passes in an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuperomedialToInferolateral¶
The number of times a biopsy instrument is passed through an area of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfPasses¶
The number of biopsy specimens obtained from an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfSpecimens¶
An indicator of whether or not a biopsy or localizing needle in an interventional procedure is seen to be in the area of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeedleInTarget¶
The number of localizing needles placed around the area of interest in an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfNeedlesAroundTarget¶
An indicator of whether or not an incision was made in the anatomy during an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IncisionMade¶
An indicator of whether or not a radio opaque microclip was placed in the anatomy during an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MicroclipPlaced¶
An indicator of the degree of success of an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConfirmationOfTarget¶
An indicator that during an interventional procedure the area of interest was fully excised and is noted in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetCompletelyContainedInTheSpecimen¶
An indicator that during an interventional procedure the area of interest was partially excised and is noted in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetPartiallyObtainedInTheSpecimen¶
An indicator that following an interventional procedure the area of interest is not seen in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetNotInTheSpecimen¶
An indicator that following an interventional procedure the targeted calcifications are noted in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationsSeenInTheCore¶
An indicator that during an interventional procedure the area of interest was fully excised and is noted in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionCompletelyRemoved¶
An indicator that during an interventional procedure the area of interest was partially excised and is noted in the resultant biopsy specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionPartiallyRemoved¶
An indicator that during an interventional procedure fluid was successfully aspirated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluidObtained¶
Color that is a light shade of brown From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LightBrownColor¶
Color that is a dark shade of red From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DarkRedColor¶
Color that is a dark shade of brown From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DarkBrownColor¶
Color that is a bright shade of red From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BrightRedColor¶
Color that is tinged with the color of blood From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodTingedColor¶
An indicator of whether or not the fluid obtained during an interventional procedure contains red blood cells From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OccultBloodTestResult¶
An indicator of whether or not fluid during an interventional procedure was sent for cytological analysis or simply discarded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ActionOnFluid¶
An indicator that fluid obtained during an interventional procedure was sent to a laboratory for analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SentForAnalysis¶
An indicator that fluid obtained during an interventional procedure was discarded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Discarded¶
A radiopaque density noted during diagnostic imaging that has associated calcific densities From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassWithCalcifications¶
A fluid-filled sac with greater than normal characteristics From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComplexCyst¶
A tumor within a cyst From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntracysticLesion¶
A tumor or lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SolidMass¶
Supporting evidence for interpretation results of an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SupplementaryDataForIntervention¶
A descriptor that further qualifies or characterizes a type of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureModifier¶
Needle size (diameter) characterization; e.g. of a biopsy needle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeedleGauge¶
An indicator of the gravity of a problem experienced by a patient, related to a procedure that was performed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeverityOfComplication¶
Distance from the hub or bushing to the tip of the needle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeedleLength¶
The collection of observations and findings from pathologic analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PathologyResults¶
The date and time that the sample was collected from the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SamplingDateTime¶
Indicates that the margin of the biopsy specimen was not involved with the tumor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Uninvolved¶
Indicates that the margin of the biopsy specimen was involved with the tumor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Involved¶
Indicates whether the nipple was involved in an interventional procedure or pathologic analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NippleInvolved¶
Indicates the number of lymph nodes removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfNodesRemoved¶
Indicates the number of lymph nodes removed that contain cancer cells From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfNodesPositive¶
The result of a test for the presence of a protein that binds with estrogen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EstrogenReceptor¶
The result of a test for the presence of a protein that binds with progesterone From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProgesteroneReceptor¶
Indicates the percentage of cells in S phase. Cell division is defined by phases; the S phase is the stage during which DNA replicates From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SPhase¶
The visible emission of non-bloody fluid from the nipple From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_bloodyDischarge_fromNipple_¶
The inability to discern normal versus abnormal breast tissue during palpation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifficultPhysical_clinicalExamination¶
An indication that a patient has or had a malignant occurrence in an area of the body other than the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CancerElsewhere¶
A salt water filled prosthetic device implanted in the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SalineImplant¶
A polymer based (plastic) prosthetic device implanted in the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PolyurethaneImplant¶
The introduction of polymeric organic silicon based material through the skin, as for breast augmentation or reconstruction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercutaneousSiliconeInjection¶
A prosthetic device that contains more than one material implanted in the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CombinationImplant¶
A breast implant placed in front of the pectoralis major muscle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pre_pectoralImplant¶
A breast implant placed behind the pectoralis major muscle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Retro_pectoralImplant¶
Using X-Ray technique and a superimposed set of crossed lines for detection or placement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mammographic_crosshair_¶
Using X-Ray technique and a superimposed aperture for detection or placement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mammographic_grid_¶
Using physical touch for detection or placement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PalpationGuided¶
The performance of a biopsy procedure using a vacuum device attached to the biopsy needle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VacuumAssisted¶
Unusual or unexpected emission of fluid From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalDischarge¶
Having experienced no adverse medical conditions related to or resulting from an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoComplications¶
TNM grouping of tumor stage, from AJCC, where primary tumor is Tis, regional lymph node is N0, and distant metastasis is M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Stage0¶
TNM grouping of tumor stage, from AJCC, where primary tumor is T1, regional lymph node is N0, and distant metastasis is M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageI¶
TNM grouping of tumor stage, from AJCC, where primary tumor is T0 or T1, with regional lymph node N1 and distant metastasis is M0, or T2 with N0 and M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIIA¶
TNM grouping of tumor stage, from AJCC, where primary tumor is T2, with regional lymph node N1 and distant metastasis is M0, or T3 with N0 and M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIIB¶
TNM grouping of tumor stage, from AJCC, where primary tumor is T0, T1 or T2, with regional lymph node N2 and distant metastasis is M0, or T3 with N1 or N2 and M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIIIA¶
TNM grouping of tumor stage, from AJCC, where primary tumor is T4, regional lymph node is N0, N1 or N2, and distant metastasis is M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIIIB¶
TNM grouping of tumor stage, from AJCC, where primary tumor is any T value, regional lymph node is N3, and distant metastasis is M0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIIIC¶
TNM grouping of tumor stage, from AJCC, where primary tumor is any T value, regional lymph node is any N value, and distant metastasis is M1 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StageIV¶
Histologic tumor grade (sometimes called Scarff-Bloom-Richardson grade) is based on the arrangement of the cells in relation to each other – whether they form tubules, how closely they resemble normal breast cells (nuclear grade) and how many of the cancer cells are in the process of dividing (mitotic count) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bloom_RichardsonGrade¶
Breast prosthetic devices are intact, not leaking, and are in a normal shape and form From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalImplants¶
Breast prosthetic devices are not symmetric, equal, corresponding in form, or are in one breast (unilateral) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AsymmetricImplants¶
Fibrous or calcific contracture of the tissue capsule that forms around a breast prosthetic device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcifiedImplant¶
Breast prosthetic device is twisted out of normal shape or form From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistortedImplant¶
Silicone from breast prosthetic device found in lymphatic tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Silicone_ladenLymphNodes¶
Silicone found in breast tissue outside of the prosthetic capsule or implant membrane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FreeSilicone¶
Protrusion of part of the structure normally encapsulating the content of the breast prosthetic device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HerniatedImplant¶
Evidence of removal of a breast prosthetic device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Explantation¶
Historical patient health information of interest to the breast health clinician From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelevantPatientInformationForBreastImaging¶
Information regarding usage by the patient of certain medications, such as hormones From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MedicationHistory¶
Interventional or non-interventional procedures previously performed on the patient, such as breast biopsies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelevantPreviousProcedures¶
Abnormal conditions experienced by the patient that serve as the reason for performing a procedure, such as a breast exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelevantIndicatedProblems¶
Personal, familial, and other health factors that may indicate an increase in the patient’s chances of developing a health condition or disease, such as breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelevantRiskFactors¶
A classification of a medicinal substance, such as hormonal contraceptive or antibiotic From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MedicationType¶
Historical patient health information for general purpose use From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelevantPatientInformation¶
The age of the patient at the first occurrence of menses From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeWhenFirstMenstrualPeriodOccurred¶
The age of the patient at the time of her first full term pregnancy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeAtFirstFullTermPregnancy¶
The age of the patient at the cessation of menses From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeAtMenopause¶
The age of the patient at the time her uterus was removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeWhenHysterectomyPerformed¶
The age of the patient at the time she had her left ovary removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeWhenLeftOvaryRemoved¶
The age of the patient at the time she had her right ovary removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeWhenRightOvaryRemoved¶
The age of a patient on the first occurrence of an event, such as the first use of a medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeStarted¶
The age of a patient on the last occurrence of an event, such as the last use of a medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeEnded¶
The date and time of the first occurrence of an event, such as the first use of a medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeStarted¶
The date and time of the last occurrence of an event, such as the last use of a medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeEnded¶
An indicator of whether an event is still in progress, such as the use of a medication or substance, or environmental exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ongoing¶
Product name of a device or substance, such as medication, to identify it as the product of a single firm or manufacturer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BrandName¶
A descriptor that further qualifies or characterizes a risk factor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RiskFactorModifier¶
A prior non-interventional exam or interventional procedure performed on a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousProcedure¶
Describes the pregnancy state of a referenced subject From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PregnancyStatus¶
A symptom experienced by a patient that is used as the reason for performing an exam or procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndicatedProblem¶
The function of the individual who is reporting information on a patient, which could be a specific health care related profession, the patient him/herself, or a relative or friend From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RoleOfPersonReporting¶
The date and time that a symptom was noted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeProblemObserved¶
The date and time of the most recent evaluation of an indicated problem From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeOfLastEvaluation¶
A patient’s biological relative who exhibits a health factor that may indicate an increase in the patient’s chances of developing a particular disease or medical problem From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FamilyMemberWithRiskFactor¶
The age at which an individual experienced a specific event, such as breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeAtOccurrence¶
The current stage of an individual in her gynecological development From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MenopausalPhase¶
An indicator of paternal or maternal relationship From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SideOfFamily¶
Relating to biological female parentage From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Maternal¶
A gynecological hormone for which the specific type is not specified; e.g. contraceptive, estrogen, Tamoxifen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnspecifiedGynecologicalHormone¶
An indicator of whether or not a patient ever provided breast milk to her offspring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastFeedingHistory¶
The average length of time that a patient provided breast milk to her offspring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AverageBreastFeedingPeriod¶
Information regarding usage by the patient of certain legal or illicit substances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubstanceUseHistory¶
A classification of a substance, such as alcohol or a legal or illicit drug From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UsedSubstanceType¶
Information regarding exposure of the patient to potentially harmful environmental factors From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EnvironmentalExposureHistory¶
A classification of a potentially harmful substance or gas in a subject’s environment, such as asbestos, lead, or carcinogens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EnvironmentalFactor¶
Previous Structured Reports that could have relevant information for a current imaging service request From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousReports¶
An indication that a patient has had a previous malignancy of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonalBreastCancerHistory¶
Indicates a previous occurrence of cancer of the lining of the uterus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfEndometrialCancer¶
Indicates a previous occurrence of cancer of the lining of the ovary From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfOvarianCancer¶
Indicates a prior diagnosis of pre-cancerous cells or tissue removed for pathologic evaluation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfHighRiskLesionOnPreviousBiopsy¶
A female patient whose menstrual periods have ceased From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PostMenopausalPatient¶
A female patient whose first child was born after the patient was 30 years old From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LateChildBearing_after30_¶
The first level genetic marker indicating risk for breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BRCA1BreastCancerGene¶
The second level genetic marker indicating risk for breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BRCA2BreastCancerGene¶
The third level genetic marker indicating risk for breast cancer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BRCA3BreastCancerGene¶
A patient’s biological aunt, grandmother, or female cousin was diagnosed with breast cancer. Definition from BI-RADS® From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WeakFamilyHistoryOfBreastCancer¶
A patient’s biological mother or sister was diagnosed with breast cancer after they had gone through menopause. Definition from BI-RADS® From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntermediateFamilyHistoryOfBreastCancer¶
A patient’s biological mother or sister was diagnosed with breast cancer before they had gone through menopause, or more than one of the patient’s first-degree relatives (biological mother or sister) were diagnosed with breast cancer after they had gone through menopause. Definition from BI-RADS® From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VeryStrongFamilyHistoryOfBreastCancer¶
Previous diagnosis of a malignancy of the prostate gland in a biological relative From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FamilyHistoryOfProstateCancer¶
The health record of a patient’s biological relatives is not known From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FamilyHistoryUnknown¶
The study of cells obtained from fluid emitted from the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NippleDischargeCytology¶
A developmental abnormality resulting in an abnormal shape of the uterus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UterineMalformations¶
A naturally occurring premature expulsion from the uterus of the products of conception - the embryo or a nonviable fetus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpontaneousAbortion¶
An ailment/abnormality or state of the female reproductive tract From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GynecologicCondition¶
A surgical operation performed on any portion of the female reproductive tract From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GynecologicSurgery¶
Prior pregnancy with a low birth weight baby or a fetus with Intrauterine Growth Restriction or Retardation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousLBWOrIUGRBirth¶
History of at least one prior pregnancy with fetal anatomic abnormality(s) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousFetalMalformation_syndrome¶
History of delivering a Rhesis Isoimmunization affected child(ren) or a child(ren) with another blood disorder From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousRHNegativeOrBloodDyscrasiaAtBirth¶
History of at least one pregnancy that contained more than one fetus; e.g. twins, triplets, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistoryOfMultipleFetuses¶
At least one fetus of this pregnancy has an anatomic abnormality(s) that is known to exist, or a “marker” is present that suggests the abnormality(s) may be present From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurrentPregnancy_KnownOrSuspectedMalformations_syndromes¶
Biological relatives have previously conceived a fetus with an anatomic abnormality(s) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FamilyHistory_FetalMalformation_syndrome¶
A subjective descriptor for an elevated amount of exposure, use, or dosage, incurring high risk of adverse effects From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- High¶
A subjective descriptor for a moderate amount of exposure, use, or dosage, incurring medium risk of adverse effects From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Medium¶
A subjective descriptor for a limited amount of exposure, use, or dosage, incurring low risk of adverse effects From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Low¶
A measurement of the rate of occurrence of which a patient takes a certain medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseFrequency¶
The quantity per unit of time that a patient was or is being exposed to an environmental irritant From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RateOfExposure¶
The quantity per unit of time that a medication or substance was or is being used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfUse¶
A qualitative descriptor for the amount of a medication that was or is being taken From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeDoseAmount¶
A qualitative descriptor for the amount of present or past exposure to an environmental irritant From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeAmountOfExposure¶
A qualitative descriptor for the amount of a medication or substance that was or is being used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeAmountOfUse¶
A qualitative descriptor for the frequency with which a medication was or is being taken From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeDoseFrequency¶
A qualitative descriptor for the frequency of present or past exposure to an environmental irritant From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeFrequencyOfExposure¶
A qualitative descriptor for the frequency with which a medication or substance was or is being used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeFrequencyOfUse¶
Patient is not known to have been exposed to or used the substance or medication From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoKnownExposure¶
Patient returns for additional images to improve the quality of the most recent exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecallForTechnicalReasons¶
Patient returns for additional images to clarify findings from the most recent exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecallForImagingFindings¶
Patient returns for additional images to clarify symptoms or signs reported by the patient or a healthcare professional at the time of the most recent exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecallForPatientSymptoms_ClinicalFindings¶
Number of births with low birth weight or intrauterine growth restriction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LBWOrIUGR¶
Filter that transmits green light while blocking the other colors, typically centered at 510-540 nm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GreenFilter¶
Filter that transmits red light while blocking the other colors, typically centered at 630-680 nm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RedFilter¶
Filter that transmits blue while blocking the other colors, typically centered at 460-480 nm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BlueFilter¶
A filter of 560nm that is used for retinal imaging and can provide good contrast and good visibility of the retinal vasculature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Yellow_greenFilter¶
A filter of 490nm that is used for retinal imaging because of excessive scattering of some retinal structures at very short wavelengths From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Blue_greenFilter¶
Filter that transmits the infrared spectrum, which is light that lies outside of the visible spectrum, with wavelengths longer than those of red light, while blocking visible light From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InfraredFilter¶
A filter that reduces reflections from non-metallic surfaces such as glass or water by blocking light waves that are vibrating at selected angles to the filter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PolarizingFilter¶
No filter used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoFilter¶
Joslin NM-1 is a 45 degree field focused centrally between the temporal margin of optic disc and the center of the macula: Center the camera on the papillomacular bundle midway between the temporal margin of the optic disc and the center of the macula. The horizontal centerline of the image should pass directly through the center of the disc From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Field1ForJoslin3Field¶
Joslin NM-2 is a 45 degree field focused superior temporal to the optic disc: Center the camera laterally approximately one-half disc diameter temporal to the center of the macula. The lower edge of the field is tangent to a horizontal line passing through the upper edge of the optic disc. The image is taken temporal to the macula but includes more retinal nasal and superior to the macula than standard field 2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Field2ForJoslin3Field¶
Joslin NM-3 is a 45 degree field focused nasal to the optic disc: This field is nasal to the optic disc and may include part of the optic disc. The horizontal centerline of the image should pass tangent to the lower edge of the optic disc From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Field3ForJoslin3Field¶
A broad or “soft” light supplied from a single source From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiffuseDirectIllumination¶
A slit reflected light microscope, which has the ability to form an image of the back scattered light from the eye in a sagittal plane. Scheimpflug cameras are able to achieve a wide depth of focus by employing the “Sheimpflug principle” where the lens and image planes are not parallel with each other. Rotating Sheimplug cameras are able to generate three-dimensional images and calculate measurements of the anterior chamber of the eye From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScheimpflugCamera¶
Lighting condition approximately 0.04 lux From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScotopicLight¶
Lighting condition approximately 4 lux From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MesopicLight¶
Lighting condition approximately 40 lux From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhotopicLight¶
Acquisition preceded by intense light From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DynamicLight¶
Calculated from values of entrance exposure in air, the X-Ray beam quality (half-value layer), and compressed breast thickness, is the energy deposited per unit mass of glandular tissue averaged over all the glandular tissue in the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AverageGlandularDose¶
The primary material in the anode of an X-Ray source From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnodeTargetMaterial¶
The average thickness of the body part examined when compressed, if compression has been applied during X-Ray exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompressionThickness¶
Thickness of Aluminum required to reduce the X-Ray output at the patient entrance surface by a factor of two From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HalfValueLayer¶
An anti-scatter device based on radiation absorbing strips above the detector; e.g. in the patient support From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayGrid¶
Exposure measurement in air at the reference point that does not include back scatter, according to MQCM 1999 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EntranceExposureAtRP¶
Average Glandular Dose to a single breast accumulated over multiple images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AccumulatedAverageGlandularDose¶
Value of the control variable used to parametrize the Automatic Exposure Control (AEC) closed loop; e.g. “Water Value” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientEquivalentThickness¶
An X-Ray Grid that does not move during exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FixedGrid¶
An X-Ray Grid with radiation absorbing strips that are focused toward the focal spot, to eliminate grid cutoff From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FocusedGrid¶
An X-Ray Grid that is designed to move during exposure, to eliminate the appearance of grid lines on the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReciprocatingGrid¶
An X-Ray Grid with radiation absorbing strips that are parallel to each other and that is used only with long source to image distances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParallelGrid¶
An X-Ray Grid with crossed radiation absorbing strips used for more complete cleanup of scatter radiation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CrossedGrid¶
No X-Ray Grid was used due to low scatter conditions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoGrid¶
The spectacle prescription for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpectaclePrescriptionReport¶
Refractive measurements of the eye to correct for inability to focus at near while wearing the distance prescription From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AddNear¶
Refractive measurements of the eye to correct for inability to focus at intermediate distance while wearing the distance prescription From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AddIntermediate¶
Refractive measurements of the eye to correct for inability to focus at the specified distance while wearing the distance prescription From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AddOther¶
The power of a prism to bend light in the horizontal direction, in prism diopters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HorizontalPrismPower¶
Direction of the base of a horizontal prism – either in (toward the nose), or out (away from the nose) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HorizontalPrismBase¶
The power of a prism to bend light in the vertical direction, in prism diopters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VerticalPrismPower¶
Direction of the base of a vertical prism – either up, or down From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VerticalPrismBase¶
Distance in mm between the pupils when the patient’s object of regard is in the distance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistancePupillaryDistance¶
Distance in mm between the pupils when the patient’s object of regard is at near From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NearPupillaryDistance¶
A patient’s vision with the correction measured by an autorefractor in place From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AutorefractionVisualAcuity¶
A patient’s vision with whichever vision correction the patient customarily wears From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HabitualVisualAcuity¶
A patient’s vision with the final spectacle prescription in place From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PrescriptionVisualAcuity¶
The spectacle prescription for the right eye From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightEyeRx¶
The spectacle prescription for the left eye From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftEyeRx¶
A macular grid thickness and volume report for a patient. The macular grid is an analytic tool described in PS3.1 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MacularGridThicknessAndVolumeReport¶
Number of images used for the macular grid measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfImagesUsedForMacularMeasurements¶
Number of samples used per Image for analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfSamplesUsedPerImage¶
A numeric rating of the quality of the entire analysis with respect to grading and diagnostic purposes. Higher numbers indicate greater quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnalysisQualityRating¶
A numeric rating of the quality of an entire image set with respect to grading and diagnostic purposes. Higher numbers indicate greater quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageSetQualityRating¶
Tear film or drops affecting test quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterferingTearsOrDrops¶
The assessment of the centricity and persistence of the visual fixation (direction of gaze) during the acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFixationQualityDuringAcquisition¶
The reason why the patient’s visual fixation was not steady or was indeterminate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFixationQualityProblem¶
The reason why the macular grid measurements may be questionable From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OphthalmicMacularGridProblem¶
Identifier of container (box, block, microscope slide, etc.) for the specimen under observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenContainerIdentifier¶
Type of processing that tissue specimen underwent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcessingType¶
Date and time of processing step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeOfProcessing¶
Description of the individual step in the tissue processing sequence From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcessingStepDescription¶
Method of sampling used to derive specimen from its parent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SamplingMethod¶
Identifier of the parent specimen that gave rise to the current specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParentSpecimenIdentifier¶
Assigning authority for parent specimen’s identifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IssuerOfParentSpecimenIdentifier¶
Parent specimen type that gave rise to current specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParentSpecimenType¶
Description of coordinate system and origin reference point on parent specimen, or parent specimen container, or image used for localizing the sampling site or location within container or image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionFrameOfReference¶
Reference to image of parent specimen localizing the sampling site; may include referenced Presentation State object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSamplingSite¶
Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference in the X dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSamplingSiteXOffset¶
Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference in the Y dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSamplingSiteYOffset¶
Location of sampling site of specimen (nominal center) relative to the Position Frame of Reference in the Z dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSamplingSiteZOffset¶
Description of specimen location, either in absolute terms or relative to the Position Frame of Reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSpecimen¶
Location of specimen (nominal center) relative to the Position Frame of Reference in the X dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSpecimenXOffset¶
Location of specimen (nominal center) relative to the Position Frame of Reference in the Y dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSpecimenYOffset¶
Location of specimen (nominal center) relative to the Position Frame of Reference in the Z dimension From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationOfSpecimenZOffset¶
Description of visual distinguishing identifiers; e.g. ink, or a particular shape of the specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualMarkingOfSpecimen¶
Assigning authority for specimen identifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IssuerOfSpecimenIdentifier¶
Dissection of specimen with submission of all its sections for further processing or examination From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DissectionWithEntireSpecimenSubmission¶
Dissection of specimen with submission of representative sections for further processing or examination From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DissectionWithRepresentativeSectionsSubmission¶
A workflow step, during which tissue specimens are stored in a climate- controlled environment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenStorage¶
Transmission illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TransmissionIllumination¶
Reflection illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReflectionIllumination¶
Epifluorescence illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EpifluorescenceIllumination¶
Brightfield illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BrightfieldIllumination¶
Darkfield illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DarkfieldIllumination¶
Oblique illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObliqueIllumination¶
Phase contrast illumination method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhaseContrastIllumination¶
Differential interference contrast method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferentialInterferenceContrast¶
Total internal reflection fluorescence method for specimen microscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalInternalReflectionFluorescence¶
A method of obtaining ophthalmic axial measurements that uses ultrasound, and that requires applanation of the cornea From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UltrasoundContact¶
A method of obtaining ophthalmic axial measurements that uses ultrasound, and that requires immersion of the patient’s eye in fluid as he lies in a supine position From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UltrasoundImmersion¶
A method of obtaining ophthalmic axial measurements that uses light From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Optical¶
Measurements taken of the corneal curvature using a manual keratometer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ManualKeratometry¶
Measurements taken of the corneal curvature using an automated keratometer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AutoKeratometry¶
Simulated Keratometry measurements derived from corneal topography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimulatedKeratometry¶
Corneal power measurements using Scheimpflug camera From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquivalentK_reading¶
The Haigis IOL calculation formula. Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 2000;238:765-73 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Haigis¶
The Haigis-L IOL calculation formula. Haigis W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg. 2008 Oct;34(10):1658-63 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Haigis_L¶
The Holladay 1 IOL calculation formula. Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988; 14:17-24 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Holladay1¶
The Holladay 2 IOL calculation formula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Holladay2¶
The Hoffer Q IOL calculation formula. Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg 1993;19:700-12. Errata. J Cataract Refract Surg 1994;20:677 and 2007;33:2-3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HofferQ¶
The Olsen IOL calculation formula. Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol. Scand. 2007: 85: 472-485 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Olsen¶
The SRKII IOL calculation formula. Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second generation formulas. J Cataract Refract Surg. 1988 Mar;14(2):136-41 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SRKII¶
The SRK-T IOL calculation formula. Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg 1990;16:333-40. Erratum 1990;16:528 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SRK_T¶
The “ACD Constant” used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACDConstant¶
The “Haigis a0” constant used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HaigisA0¶
The “Haigis a1” constant used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HaigisA1¶
The “Haigis a2” constant used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HaigisA2¶
The “Hoffer pACD Constant” used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HofferPACDConstant¶
The “Surgeon Factor” constant used in IOL calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SurgeonFactor¶
Anterior chamber depth defined as the front of the cornea to the front of the lens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FrontOfCorneaToFrontOfLens¶
Anterior chamber depth defined as the back of the cornea to the front of the lens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BackOfCorneaToFrontOfLens¶
Refers to the anterior lens when there are two lenses in the eye. The distance, in mm, from the anterior surface of the lens to the posterior surface of the lens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleOrAnteriorLens¶
Refers to the posterior lens when there are two lenses in the eye. The distance, in mm, from the anterior surface of the lens to the posterior surface of the lens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorLens¶
Value obtained from measurements taken by the device creating this SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementFromThisDevice¶
Value obtained by data transfer from an external source - not from measurements taken by the device providing the value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExternalDataSource¶
Axial Measurements DICOM SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AxialMeasurementsSOPInstance¶
Refractive Measurements DICOM SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RefractiveMeasurementsSOPInstance¶
Standard Deviation is a simple measure of the variability of a data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardDeviationOfMeasurementsUsed¶
Signal to Noise Ratio of the data samples taken to create a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalToNoiseRatio¶
Projection from 2D image pixels to 3D Cartesian coordinates based on a spherical mathematical model From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SphericalProjection¶
Mapping from 2D image pixels to 3D Cartesian coordinates based on measurements of the retinal surface; e.g. of the retina, derived via a measurement technology such as Optical Coherence Tomography, Ultrasound etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SurfaceContourMapping¶
Test pattern, nominally covering an area within 24° of fixation. Consists of 54 test points a minimum of 3° from each meridian and placed 6° apart. The “-2” distinguishes this from another 24° pattern (no longer supported) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField24_2TestPattern¶
Test pattern, nominally covering an area within 10° of fixation. Consists of 68 test points a minimum of 1° from each meridian and placed 2° apart. The “-2” in this case indicates its point layout to be similar to the 30-2 and 24-2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField10_2TestPattern¶
Test pattern consisting of test point locations within 30° of fixation. Consists of 76 test points a minimum of 3° from each meridian and placed 6° apart. The “-2” distinguishes this from another 30° pattern (no longer supported) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField30_2TestPattern¶
Test pattern consisting of 60 test point locations between 30° and 60° of fixation a minimum of 6° from each meridian and placed 12° apart. The “-4” distinguishes this from a similar 60° pattern having 4 additional points From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField60_4TestPattern¶
Test pattern consisting of 16 test point locations within 10° of fixation a minimum of 1° from each meridian and placed 2° apart From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldMaculaTestPattern¶
Test pattern consisting of 40 test point locations within 30° of fixation that spread out radially from fixation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldCentral40PointTestPattern¶
Test pattern consisting of 76 test point locations within 30° of fixation a minimum of 3° from each meridian and placed 6° apart From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldCentral76PointTestPattern¶
Test pattern consisting of 60 test point locations between 30° and 60° of fixation a minimum of 6° from each meridian and placed 12° apart From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldPeripheral60PointTestPattern¶
Test pattern consisting of 81 test point locations within 60° of fixation that spread out radially from fixation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFullField81PointTestPattern¶
Test pattern consisting of 120 test point locations within 60° of fixation that spread out radially from fixation, concentrated in the nasal hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFullField120PointTestPattern¶
Test pattern for Glaucoma and general visual field assessment with 59 test locations of which 16 test locations are in the macular area (up to 10° eccentricity) and where the density of test location is reduced with eccentricity. The test can be extended with the inclusion of 14 test locations between 30° and 60° eccentricity, 6 of which are located at the nasal step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldGTestPattern¶
Test pattern for the macular area. Orthogonal test pattern with 0.7° spacing within the central 4° of eccentricity and reduced density of test locations between 4 and 10, 5° of eccentricity. 81 test locations over all. The test can be extended to include the test locations of the Visual Field G Test Pattern between 10, 5° and 60° From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldMTestPattern¶
Full field test pattern with 48 test locations from 0-30° and 82 test locations from 30-70°. Reduced test point density with increased eccentricity. Can be combined with screening and threshold strategies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField07TestPattern¶
Low Vision Central. Orthogonal off-center test pattern with 6° spacing. 75 test locations within the central 30°. Corresponds with the 32/30-2 excluding the 2 locations at the blind spot, including a macular test location. The LVC is linked with a staircase threshold strategy starting at 0 dB intensity and applies stimulus area V From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldLVCTestPattern¶
General test corresponding to the 30-2 but excluding the 2 test locations in the blind spot area, hence with 74 instead of 76 test locations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldCentralTestPattern¶
Swedish Interactive Thresholding Algorithm (SITA). Strategy gains testing efficiency through use of visual field and information theory models. In: Bengtsson B, Olsson J, Heijl A, Rootzen H. A new generation of algorithms for computerized threshold perimetry, SITA. Acta Ophthalmologica Scandinavica, 1997, 75: 368-375 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldSITA_StandardTestStrategy¶
Adaptation of SITA testing methods to Blue-Yellow testing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldSITA_SWAPTestStrategy¶
Similar to SITA-Standard but with less strict criteria for closing test points. Intended for patients who must be tested in the shortest possible time. In: Bengtsson B, Hejl A. SITA Fast, a new rapid perimetric threshold test. Description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmologica Scandinavica, 1998, 76: 431-437 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldSITA_FastTestStrategy¶
Threshold test algorithm that determines a patient’s sensitivity at each test point in the threshold test pattern by adjusting intensity by 4 dB steps until the patient changes their response, and then adjusts the intensity in the opposite direction by 2 dB steps until the patient changes their response again. The last stimulus seen by the patient is recognized as the threshold for that point. The starting values are determined by first thresholding a “primary” point in each quadrant then using the results of each primary point to determine the starting values for neighboring points From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFullThresholdTestStrategy¶
Similar to the Full Threshold algorithm except that it steps by 3 dB and only crosses the threshold only once. In: Flanagan JG, Wild JM, Trope GE. Evaluation of FASTPAC, a new strategy for threshold estimation with the Humphrey Field Analyzer, in a glaucomatous population. Ophthalmology, 1993, 100: 949-954 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFastPacTestStrategy¶
Identical to Full Threshold except that starting values are determined by the results of a previous test performed using the same test pattern and the Full Threshold test strategy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFullFromPriorTestStrategy¶
Similar to FastPac except that the steps are pseudo-dynamic (differ based on the intensity of the last presentation) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldOptimaTestStrategy¶
Suprathreshold testing strategy, in which each point is initially tested using stimulus that is 6 dB brighter than the expected hill of vision. If the patient does not respond, the stimulus is presented a second time at the same brightness. If the patient sees either presentation, the point is marked as “seen”; otherwise it is marked as “not seen” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldTwo_ZoneTestStrategy¶
An extension of the two-zone strategy in which test points where the second stimulus is not seen are presented with a third stimulus at maximum brightness From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldThree_ZoneTestStrategy¶
An extension of the two-zone strategy, in which test points where the second stimulus is not seen receive threshold testing to quantify the depth of any detected scotomas From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldQuantify_DefectsTestStrategy¶
Tendency Oriented Perimetry. Fast thresholding algorithm. Test strategy makes use of the interaction between neighboring test locations to reduce the test time compared to normal full threshold strategy by 60-80%. In: Morales J, Weitzman ML, Gonzalez de la Rosa M. Comparison between Tendency-Oriented Perimetry (TOP) and octopus threshold perimetry. Ophthalmology, 2000, 107: 134-142 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldTOPTestStrategy¶
Dynamic strategy is a fast thresholding strategy reducing test duration by adapting the dB step sizes according to the frequency-of-seeing curve of the threshold. Reduction of test time compared to normal full threshold strategy 30-50% From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldDynamicTestStrategy¶
Traditional full threshold staircase strategy. Initial intensities are presented, based on anchor point sensitivities in each quadrant and based on already known neighboring sensitivities. In a first run, thresholds are changed in 4dB steps until the first response reversal. Then the threshold is changed in 2 dB steps until the second response reversal. The threshold is calculated as the average between the last seen and last not-seen stimulus, supposed to correspond with the 50% point in the frequency-of-seeing curve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldNormalTestStrategy¶
One level screening test: Each test location is tested with a single intensity. The result is shown as seen or not-seen. The intensity can either be a 0 dB stimulus or a predefined intensity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField1_LTTestStrategy¶
Two level screening test: Each test location is initially tested 6 dB brighter than the age corrected normal value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField2_LTTestStrategy¶
Low Vision Strategy is a full threshold normal strategy with the exception that it starts at 0 dB intensity and applies stimulus area V From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldLVSTestStrategy¶
German Adaptive Threshold Estimation is a fast strategy based on a modified 4-2 staircase algorithm, using prior visual fields to calculate the starting intensity. In: Chiefer U, Pascual JP, Edmunds B, Feudner E, Hoffmann EM, Johnson CA, Lagreze WA, Pfeiffer N, Sample PA, Staubach F, Weleber RG, Vonthein R, Krapp E, Paetzold J. Comparison of the new perimetric GATE strategy with conventional full-threshold and SITA standard strategies. Investigative Ophthalmology and Visual Science, 2009, 51: 488-494 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldGATETestStrategy¶
Similar to GATE. The i stands for initial. If there was no prior visual field test to calculate the starting values, an anchor point method is used to define the local start values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldGATEiTestStrategy¶
A test started as two level screening test. In the course of the test, the threshold of relative defects and/or normal test locations has been quantified using the dynamic threshold strategy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField2LT_DynamicTestStrategy¶
A test started as two level screening test. In the course of the test, the threshold of relative defects and/or normal test locations has been quantified using the normal full threshold strategy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualField2LT_NormalTestStrategy¶
Takes neighborhood test point results into account and offers stimuli with an adapted value to save time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldFastThresholdTestStrategy¶
Continuous Luminance Incremental Perimetry, which measures at first the individual reaction time of the patient and threshold values in every quadrant. The starting value for the main test is slightly below in individual threshold From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldCLIPTestStrategy¶
A supra threshold screening strategy. The starting stimuli intensities depend on the classification of the patient’s visual hill by measuring the central (fovea) or peripheral (15° meridian) threshold. The result of each dot slightly underestimates the sensitivity value (within 5 dB) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldCLASSStrategy¶
Mode for determining the starting luminance for screening test points - the starting luminance s is chosen based on the age of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgeCorrected¶
Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the results of thresholding a set of “primary” test points (one in each quadrant) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThresholdRelated¶
Mode for determining the starting luminance for screening test points - in this case, all starting luminance is set to the same value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleLuminance¶
Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the result of the foveal threshold value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FovealSensitivityRelated¶
Mode for determining the starting luminance for screening test points - the starting luminance is chosen based on the result of four threshold values measured near the 15° meridian (one in each quadrant) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelatedToNonMacularSensitivity¶
Real time evaluation of the camera image to recognize blinks and fixation losses with influence on the test procedure. Blinks that interfere with stimuli presentation cause the automated repetition of such stimulus presentations. Fixation losses can be used to delay the stimulus presentation until correct fixation is regained From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AutomatedOptical¶
A method of monitoring the patient’s fixation by periodically presenting stimulus in a location on the background surface that corresponds to the patient’s blind spot From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BlindSpotMonitoring¶
A method of monitoring the patient’s fixation by presenting the stimulus to the patient’s macula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MacularFixationTesting¶
A method of monitoring the patient’s fixation by observation from the examiner of the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObservationByExaminer¶
Analysis Results are outside normal limits From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OutsideNormalLimits¶
Analysis Results are borderline From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Borderline¶
Analysis Results identify abnormally high sensitivity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormallyHighSensitivity¶
Analysis Results identify general reduction in sensitivity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GeneralReductionInSensitivity¶
Analysis Results identify Borderline and general reduction in sensitivity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BorderlineAndGeneralReductionInSensitivity¶
Index of a patient’s remaining visual field normalized for both age and generalized defect From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldIndex¶
Estimate of the portion of a patient’s visual field loss that is diffuse (i.e., spread evenly across all portions of the visual field) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldLossDueToDiffuseDefect¶
Estimate of the portion of a patient’s visual field loss that is local (i.e., not spread evenly across all portions of the visual field) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualFieldLossDueToLocalDefect¶
An analysis of asymmetry between zones of the superior and inferior visual field. It is designed to be specific for defects due to glaucoma From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlaucomaHemifieldTestAnalysis¶
The data output of an optical fixation monitoring process, consisting of a list of positive and negative numbers indicating the quality of patient fixation over the course of a visual field test. The value 0 represents the initial fixation. Negative numbers indicate a measuring error (i.e., the patient blinked). Positive numbers quantify the degree of eccentricity from initial fixation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OpticalFixationMeasurements¶
An image of at least 15° angular subtend that is centered on the macula; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaculaCentered¶
An image of at least 15° angular subtend that is centered on the optic disc; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiscCentered¶
An image of any angular subtend that is centered on a lesion located in any region of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionCentered¶
An image of at least 15° angular subtend centered midway between the disc and macula and containing at least a portion of the disc and both the disc and the macula; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Disc_maculaCentered¶
An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-temporal and superior-nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_superior¶
An image of at least 15° angular subtend positioned between the central zone and the equator in the superior-temporal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_superiorTemporal¶
An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-temporal and inferior-temporal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_temporal¶
An image of at least 15° angular subtend positioned between the central zone and the equator in the inferior-temporal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_inferiorTemporal¶
An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the inferior-temporal and inferior-nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_inferior¶
An image of at least 15° angular subtend positioned between the central zone and the equator in the inferior-nasal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_inferiorNasal¶
An image of at least 15° angular subtend positioned between the central zone and the equator, and spanning both the superior-nasal and inferior-nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_nasal¶
An image of at least 15° angular subtend positioned between the central zone and the equator in the superior-nasal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Mid_peripheral_superiorNasal¶
An image of at least 15° angular subtend positioned between the equator and the ora serrata, and spanning both the superior temporal and superior nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_superior¶
An image of at least 15° angular subtend positioned between the equator and ora serrata in the superior-temporal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_superiorTemporal¶
An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the superior-temporal and inferior-temporal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_temporal¶
An image of at least 15° angular subtend positioned between the equator and ora serrata in the inferior-temporal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_inferiorTemporal¶
An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the inferior-temporal and inferior-nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_inferior¶
An image of at least 15° angular subtend positioned between the equator and ora serrata in the inferior-nasal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_inferiorNasal¶
An image of at least 15° angular subtend positioned between the equator and ora serrata, and spanning both the superior-nasal and inferior-nasal quadrants of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_nasal¶
An image of at least 15° angular subtend positioned between the equator and ora serrata in the superior-nasal quadrant of the fundus; see Section U.1.8 “Relative Image Position Definitions” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peripheral_superiorNasal¶
Identifies the use of physical signals with respect to time to capture information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeDomain¶
Identifies the use of physical signals with respect to multiple frequencies to capture information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpectralDomain¶
No compensation algorithm for corneal birefringence From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoCornealCompensation¶
Algorithm to compensate for variability in corneal birefringence From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealBirefringenceCompensation¶
Measurement of the retinal surface contour relative to an assigned datum plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetinalTopography¶
Measurement approximating the distance related to the structure between the internal limiting membrane (ILM) and the outer boarder of the retinal nerve fiber layer (RNFL); see Section III.6 “Retinal Thickness Definition” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetinalNerveFiberLayerThickness¶
Measurement approximating the distance related to the structure between the ILM and the outer border of the inner plexiform layer (IPL), called the ganglion cell complex (GCC); see Section III.6 “Retinal Thickness Definition” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GanglionCellComplexThickness¶
Measurement approximating the distance related to the structure between the ILM and the inner-outer segment junction (IS-OS); see Section III.6 “Retinal Thickness Definition” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalRetinalThickness_ILMToIS_OS_¶
Measurement approximating the distance related to the structure between the ILM and the retinal pigment epithelium (RPE); see Section III.6 “Retinal Thickness Definition” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalRetinalThickness_ILMToRPE_¶
Measurement approximating the distance related to the structure between the ILM and the Bruch’s membrane (BM); see Section III.6 “Retinal Thickness Definition” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalRetinalThickness_ILMToBM_¶
Thickness of a component of the posterior segment of the eye; e.g. thickness of retina, choroid, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbsoluteOphthalmicThickness¶
Ophthalmic Thickness map based upon statistical significance category (such as percentile) from a normative data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThicknessDeviationCategoryFromNormativeData¶
Ophthalmic Thickness map based upon deviation (such as microns) from a normative data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThicknessDeviationFromNormativeData¶
Ophthalmic Thickness Map related to another Ophthalmic Thickness Map or another SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelatedOphthalmicThicknessMap¶
An anatomic point centered midway between the disc and fovea centralis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Disc_Fovea¶
Assuming the null hypothesis is true, the conditional percent probability of observing this result is not statistically significant From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- P_5_¶
Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 95% unlikely to happen by chance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- P_5_¶
Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 98% unlikely to happen by chance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- P_2_¶
Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 99% unlikely to happen by chance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- P_1_¶
Assuming the null hypothesis is true, the conditional percent probability of observing this result is statistically significant, 99.5% unlikely to happen by chance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- P_0_5_¶
A two dimensional representation of the axial curvature of the cornea. Axial curvature is calculated from the reciprocal of the distance from a point on a meridian normal at the point to the corneal topographer axis. Also known as sagittal curvature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealAxialPowerMap¶
A two dimensional representation of the instantaneous curvature of the cornea. Instantaneous curvature is calculated from the reciprocal of the distance from a point on a meridian normal at the point to the center of curvature of that point. Also called tangential curvature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealInstantaneousPowerMap¶
A two dimensional representation of the refractive power of the cornea. Corneal refractive power is calculated using Snell’s Law From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealRefractivePowerMap¶
A two dimensional representation of the elevation of the cornea. Elevation is calculated as the distance from a point on the corneal surface to a point on a reference surface along a line parallel to the corneal topographer axis. For the purpose of visualization the reference surface is usually a sphere or an ellipse From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealElevationMap¶
A two dimensional representation of a wavefront aberration surface of the cornea. Wavefront aberration surface is calculated from the corneal elevation data fit with either the Zernike polynomial series or the Fourier Series. Maps generally display total aberrations and selectable higher order aberrations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CornealWavefrontMap¶
A device that measures corneal anterior surface shape using elevation-based methods (stereographic and light slit-based). Rasterstereography images a grid pattern illuminating the fluorescein dyed tear film with 2 cameras to produce 3D. Slit-based devices scan the cornea, usually by rotation about the instrument axis centered on the cornea vertex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Elevation_basedCornealTomographer¶
A reflection-based device that projects a pattern of light onto the cornea and an image of the reflection of that pattern from the tear film is recorded in one video frame. Light patterns include the circular mire pattern (Placido disc) and spot matrix patterns. Sequential scanning of light spots reflected from the corneal surface is also used requiring multiple video frames for recording From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Reflection_basedCornealTopographer¶
An Interference-based device that projects a beam of light onto and through the cornea. Light reflected from within the cornea is combined with a reference beam giving rise to an interference pattern. Appropriately scanned, this imaging is used to construct 3-dimensional images of the cornea from anterior to posterior surfaces; e.g. swept source OCT From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Interferometry_basedCornealTomographer¶
A structured report containing the results of computer-aided detection or diagnosis applied to chest imaging and associated clinical information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ChestCADReport¶
The shadow of an absorber that attenuates the X-Ray beam more effectively than do surrounding absorbers. In a radiograph, any circumscribed area that appears more nearly white (of lesser photometric density) than its surround [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Opacity¶
A unique identifier for a series of DICOM SOP instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeriesInstanceUID¶
A named anatomic region within the chest cavity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AssociatedChestComponent¶
A collection of opacities detected within the continuum of loose connective tissue throughout the lung, that is not expected in a diagnostically normal radiograph From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalInterstitialPattern¶
A type of anatomy that is expected to be detectable on a radiographic (X-Ray based) image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiographicAnatomy¶
Characteristic of the extent of spreading of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistributionDescriptor¶
Characteristic of the clarity of the boundary or edges of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BorderDefinition¶
The part(s) of the anatomy affected or encompassed by a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SiteInvolvement¶
Characteristic of the matter or substance within a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TypeOfContent¶
Characteristic of the surface or consistency of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TextureDescriptor¶
Position of the X-Ray beam about the patient from the RAO to LAO direction where movement from RAO to vertical is positive From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionerPrimaryAngle¶
Position of the X-Ray beam about the patient from the caudal to cranial direction where movement from caudal to vertical is positive From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionerSecondaryAngle¶
The zone, lobe or segment within the chest cavity in which a finding or feature is situated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LocationInChest¶
Vertical refers to orientation parallel to the superior-inferior (cephalad- caudad) axis of the body, with horizontal being perpendicular to this, and an oblique orientation having projections in both the horizontal and vertical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrientationDescriptor¶
Characteristic of the shape formed by the boundary or edges of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BorderShape¶
Indicates whether a finding was considered a target lesion, non-target lesion, or non-lesion during evaluation of a baseline series, according to a method such as RECIST From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaselineCategory¶
The extent of a detected cavity, represented as the percent of the surrounding volume that it occupies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CavityExtentAsPercentOfVolume¶
The extent of a detected calcification, represented as the percent of the surrounding surface that it occupies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationExtentAsPercentOfSurface¶
The extent of a detected calcification, represented as the percent of the surrounding volume that it occupies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationExtentAsPercentOfVolume¶
A heading for the reporting of response evaluation for treatment of solid tumors From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResponseEvaluation¶
The system applied in the reporting of response evaluation for treatment of solid tumors From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResponseEvaluationMethod¶
Response Evaluation Criteria In Solid Tumors; see Normative References From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RECIST¶
A term that further specifies the name of an item that is an inferred correlation relating two or more individual findings or features From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompositeFeatureModifier¶
A term that further specifies the name of an item that was detected on one image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleImageFindingModifier¶
A qualitative descriptor for the extent of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SizeDescriptor¶
A qualitative descriptor for the thickness of tubular structures, such as blood vessels From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WidthDescriptor¶
A characteristic that further describes the nature of an opacity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OpacityDescriptor¶
The type of adverse affect that a finding or feature is having on the surrounding anatomy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalDistributionOfAnatomicStructure¶
Response evaluation method as defined in chapter 5, “Reporting of Response” of the WHO Handbook for Reporting Results for Cancer Treatment; see Normative References From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WHO¶
Identification of the morphology of detected calcifications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalcificationDescriptor¶
A quantitative numerical statement of the relative attenuation of the X-Ray beam at a specified point. Coefficient that describes the fraction of a beam of X-Rays or gamma rays that is absorbed or scattered per unit thickness of the absorber. This value basically accounts for the number of atoms in a cubic cm volume of material and the probability of a photon being scattered or absorbed from the nucleus or an electron of one of these atoms. Usually expressed in Hounsfield units [referred to as CT Number in Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AttenuationCoefficient¶
An X-Ray attenuation coefficient that is used as a threshold; e.g. in calcium scoring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThresholdAttenuationCoefficient¶
An opacity that is not expected in a diagnostically normal radiograph From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalOpacity¶
A textual description of the mathematical method of calculation that resulted in a calculated value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalculationDescription¶
American College of Radiology. ACR Standard for the Performance of Pediatric and Adult Chest Radiography. In: Standards. Reston, Va: 2001:95-98 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformanceOfPediatricAndAdultChestRadiography_ACR¶
American College of Radiology. ACR Position Statement for Quality Control and Improvement, Safety, Infection Control, and Patient Concerns. In: Practice Guidelines and Technical Standards. Reston, Va: 2001:iv From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRPositionStatement¶
A descriptor for a non-lesion object finding or feature, used to indicate whether the object was detected as being internal or external to the patient’s body From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_lesionModifier¶
A concept modifier for an Osseous Anatomy, or bone related, finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OsseousModifier¶
A text label used for tracking a finding or feature, potentially across multiple reporting objects, over time. This label shall be unique within the domain in which it is used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TrackingIdentifier¶
A unique identifier used for tracking a finding or feature, potentially across multiple reporting objects, over time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TrackingUniqueIdentifier¶
Disappearance of all target lesions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetLesionCompleteResponse¶
At least a 30% decrease in the sum of the Longest Diameter of target lesions, taking as reference the baseline sum Longest Diameter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetLesionPartialResponse¶
At least a 20% increase in the sum of the Longest Diameter of target lesions, taking as reference the smallest sum Longest Diameter recorded since the treatment started, or the appearance of one or more new lesions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetLesionProgressiveDisease¶
Neither sufficient shrinkage to qualify for Partial Response nor sufficient increase to qualify for Progressive Disease, taking as reference the smallest sum Longest Diameter since the treatment started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetLesionStableDisease¶
Disappearance of all non-target lesions and normalization of tumor marker level From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_TargetLesionCompleteResponse¶
Persistence of one or more non-target lesions and/or maintenance of tumor marker level above the normal limits From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_TargetLesionIncompleteResponseOrStableDisease¶
Appearance of one or more new lesions and/or unequivocal progression of existing non-target lesions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_TargetLesionProgressiveDisease¶
The current response evaluation for treatment of solid tumors, according to a method such as RECIST From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurrentResponse¶
Best response recorded from the start of the treatment until disease progression/recurrence, taking as reference for Progressive Disease the smallest measurements recorded since the treatment started, according to a method such as RECIST From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BestOverallResponse¶
A text identifier of an anatomic feature when a multiplicity of features of that type may be present, such as “Rib 1”, “Rib 2” or thoracic vertebrae “T1” or “T2” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnatomicIdentifier¶
A measured or calculated evaluation of response; e.g. according to a method such as RECIST, the value would be the calculated sum of the lengths of the longest axes of a set of target lesions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementOfResponse¶
Of or relating to a bronchial (lung) specific channel for the conveyance of a body fluid From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bronchovascular¶
Of, relating to, or composed of bone From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Osseous¶
The smallest unit of lung surrounded by connective tissue septa; the unit of lung subtended by any bronchiole that gives off three to five terminal bronchioles [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SecondaryPulmonaryLobule¶
A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the maximum X-Ray attenuation coefficient and the area of calcium deposits From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgatstonScoringMethod¶
A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the volume of each calcification, typically expressed in mm3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeScoringMethod¶
A method of calculating an overall calcium score, reflecting the calcification of coronary arteries, based on the total mass of calcification, typically expressed in mg From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassScoringMethod¶
A measure often arrived at through calculation of findings from CT examination, which is a common predictor of significant stenosis of the coronary arteries From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumScore¶
The combination of a focus of pneumonia due to a primary infection with granulomas in the draining hilar or mediastinal lymph nodes [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PrimaryComplex¶
General or local decrease in the apparent width of visible pulmonary vessels, suggesting less than normal blood flow (reduced blood flow) [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Oligemia¶
Linear opacity of very fine width, i.e., a nearly one dimensional opacity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalLines_1D_¶
Area of abnormal very low X-Ray attenuation, typically lower than aerated lung when occurring in or projecting over lung, or lower than soft tissue when occurring in or projecting over soft tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalLucency¶
A calcific opacity within the lung that may be organized, but does not display the trabecular organization of true bone [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalCalcifications¶
Relatively homogeneous, extended, pattern of abnormal opacity in the lung, typically low in contrast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalTexture¶
A collection of innumerable small, linear, and nodular opacities that together produce a composite appearance resembling a net with small superimposed nodules. The reticular and nodular elements are dimensionally of similar magnitude [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReticulonodularPattern¶
Irregular septal thickening that suggests the appearance of a row of beads; usually a sign of lymphangitic carcinomatosis, but may also occur rarely in sarcoidosis [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeadedSeptumSign¶
A collection of innumerable, small discrete opacities ranging in diameter from 2-10 mm, generally uniform in size and widespread in distribution, and without marginal spiculation [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NodularPattern¶
An irregular band of peripheral pulmonary opacity adjacent to visceral pleura that simulates the appearance of a pleural plaque and is formed by coalescence of small nodules [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pseudoplaque¶
A ring of opacities (usually representing a dilated, thick-walled bronchus) in association with a smaller, round, soft tissue opacity (the adjacent pulmonary artery) suggesting a “signet ring” [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Signet_ringSign¶
Equivalent of air bronchogram, but in airways assumed to be bronchioles because of peripheral location and diameter [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirBronchiologram¶
Radiographic shadow of an air-containing bronchus; presumed to represent an air-containing segment of the bronchial tree (identity often inferred) [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirBronchogram¶
Air in a crescentic shape in a nodule or mass, in which the air separates the outer wall of the lesion from an inner sequestrum, which most commonly is a fungus ball of Aspergillusspecies [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirCrescent¶
Ground-glass opacity surrounding the circumference of a nodule or mass. May be a sign of invasive aspergillosis or hemorrhage of various causes [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HaloSign¶
Flag denoting that this lesion was identified, at baseline, as a target lesion intended for tracking over time [RECIST] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetLesionAtBaseline¶
Flag denoting that this lesion was not identified, at baseline, as a target lesion, and was not intended for tracking over time [RECIST] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_TargetLesionAtBaseline¶
Flag denoting that this finding was identified, at baseline, as a category other than a lesion, and was not intended for tracking over time [RECIST] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_LesionAtBaseline¶
Local or general reduction in the caliber of visible pulmonary vessels, presumed to result from decreased flow occasioned by contraction of muscular pulmonary arteries [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Vasoconstriction¶
Local or general increase in the width of visible pulmonary vessels resulting from increased pulmonary blood flow [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Vasodilation¶
A manifestation of lung disease in which bronchi, pulmonary vessels, a fissure or fissures, or septa of secondary pulmonary lobules are abnormally displaced [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArchitecturalDistortion¶
A patchwork of regions of varied attenuation, interpreted as secondary to regional differences in perfusion [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MosaicPerfusion¶
Increased blood flow to the lungs or a portion thereof, manifested by a general or local increase in the width of visible pulmonary vessels [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pleonemia¶
The common boundary between the shadows of two juxtaposed structures or tissues of different texture or opacity (edge, border) [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Interface¶
A longitudinal opacity no greater than 2 mm in width [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Line¶
The shadow of an absorber that attenuates the primary X-Ray beam less effectively than do surrounding absorbers. In a radiograph, any circumscribed area that appears more nearly black (of greater photometric density) than its surround [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Lucency¶
A midlung region, characterized by the absence of large blood vessels and by a paucity of small blood vessels, that corresponds to the minor fissure and adjacent peripheral lung [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MidlungWindow¶
The angle formed by the right and left main bronchi at the tracheal bifurcation [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CarinaAngle¶
The pulmonary artery and its immediate branches in a secondary lobule; HRCT depicts these vessels in certain cases; a.k.a. core structures or lobular core structures [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CentrilobularStructures¶
A vertically oriented linear or curvilinear opacity approximately 1-2 mm wide, commonly projected on the tracheal air shadow [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnteriorJunctionLine¶
A vertically oriented, linear or curvilinear opacity approximately 2 mm wide, commonly projected on the tracheal air shadow, and usually slightly concave to the right [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorJunctionLine¶
A space in the right side of the mediastinum into which the medial edge of the right lower lobe extends [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AzygoesophagealRecessInterface¶
A vertically oriented interface usually seen in a frontal chest radiograph to the left of the thoracic vertebral column [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParaspinalLine¶
A vertically oriented linear opacity ranging in width from 2-5 mm, extending from the thoracic inlet to the bifurcation of the trachea, and visible only on lateral radiographs of the chest [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PosteriorTrachealStripe¶
A vertically oriented linear opacity approximately 2-3 mm wide extending from the thoracic inlet to the right tracheobronchial angle [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightTrachealStripe¶
A longitudinal composite opacity measuring 2-5 mm in width; acceptable when limited to anatomic structures within the mediastinum [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Stripe¶
A gap or passage through an anatomical part or organ; especially : a gap through which another part or organ passes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hiatus¶
A small rounded elevation or eminence on the first rib for the attachment of the scalenus anterior From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RibScaleneTubercle¶
A groove that serves for the transmission of the vertebral artery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VertebralIntervertebralNotch¶
The concave depression of the anterior surface of the scapula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubscapularFossa¶
A sloping ridge dividing the dorsal surface of the scapula into the supraspinatous fossa (above), and the infraspinatous fossa (below) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScapularSpine¶
The portion of the dorsal surface of the scapula above the scapular spine From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScapularSupraspinatusFossa¶
The portion of the dorsal surface of the scapula below the scapular spine From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScapularInfraspinatusFossa¶
The portion of the aortic arch that defines the transition between its ascending and descending limbs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AorticKnob¶
Section of Azygos vein near the fourth thoracic vertebra, where it arches forward over the root of the right lung, and ends in the superior vena cava, just before that vessel pierces the pericardium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArchOfTheAzygosVein¶
A local collection of gas and liquid that, when traversed by a horizontal X-Ray beam, creates a shadow characterized by a sharp horizontal interface between gas density above and liquid density below [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Air_fluidLevel¶
A circumferential pattern of fine linear spicules, approximately 5 mm long, extending outward from the margin of a solitary pulmonary nodule through a zone of relative lucency [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CoronaRadiata¶
A number of closely approximated ring shadows representing air spaces 5-10 mm in diameter with walls 2-3 mm thick that resemble a true honeycomb; implies “end-stage” lung [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HoneycombPattern¶
A straight, curved, or irregular linear opacity that is visible in multiple projections; usually situated in the lower half of the lung; vary markedly in length and width [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fleischner_sLine_s_¶
Fine linear opacities present in a lobule when the intralobular interstitium is thickened. When numerous, they may appear as a fine reticular pattern [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntralobularLines¶
Essentially straight linear opacity 2-6 cm in length and 1-3 mm in width, usually in an upper lung zone [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KerleyALine¶
A straight linear opacity 1.5-2 cm in length and 1-2 mm in width, usually at the lung base [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KerleyBLine¶
A group of branching, linear opacities producing the appearing of a fine net, at the lung base [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KerleyCLines¶
Elongated opacity, usually several millimeters wide and up to about 5 cm long, often extending to the pleura, which may be thickened and retracted at the site of contact [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParenchymalBand¶
A collection of innumerable small linear opacities that together produce an appearance resembling a net [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReticularPattern¶
Usually used in the plural, a generic term for linear opacities of varied distribution produced when the interstitium between pulmonary lobules is thickened [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeptalLine_s_¶
A thin curvilinear opacity, a few millimeters or less in thickness, usually less than 1 cm from the pleural surface and paralleling the pleura [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubpleuralLine¶
Parallel or slightly convergent linear opacities that suggest the planar projection of tubular structures and that correspond in location and orientation to elements of the bronchial tree [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TramlineShadow¶
Paired, parallel, or slightly convergent linear opacities presumed to represent the walls of a tubular structure seen en face; used if the anatomic nature of a shadow is obscure [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TubularShadow¶
The opacity of a radiographic shadow to visible light; film blackening; the term should never be used to mean an “opacity” or “radiopacity” [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Density¶
Subpleural increased attenuation in dependent lung. The increased attenuation disappears when the region of lung is nondependent; a.k.a. dependent increased attenuation [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DependentOpacity¶
Hazy increased attenuation of lung, but with preservation of bronchial and vascular margins; caused by partial filling of air spaces, interstitial thickening, partial collapse of alveoli, normal expiration, or increased capillary blood volume [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GroundGlassOpacity¶
Any ill-defined opacity in the lung [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Infiltrate¶
Discrete, small, round, focal opacity of at least soft tissue attenuation and with a diameter no greater than 7 mm [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Micronodule¶
A shadow produced by a local collection of fluid in one of the interlobar fissures, usually elliptic in one radiographic projection and rounded in the other, resembling a tumor [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhantomTumor_pseudotumor_¶
Any perceptible discontinuity in film blackening attributed to the attenuation of the X-Ray beam by a specific anatomic absorber or lesion on or within the body of the patient; to be employed only when more specific identification is not possible [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Shadow¶
Term used to define a reticular pattern specific to pneumoconioses [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SmallIrregularOpacities¶
Term used to define a nodular pattern specific to pneumoconioses [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SmallRoundedOpacities¶
Nodular dilation of centrilobular branching structures that resembles a budding tree and represents exudative bronchiolar dilation [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Tree_in_budSign¶
Any extended, finely granular pattern of pulmonary opacity within which normal anatomic details are partly obscured [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GranularPattern¶
A collection of tiny discrete opacities in the lungs, each measuring 2 mm or less in diameter, generally uniform in size and widespread in distribution [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MiliaryPattern¶
Generalized pattern of relatively well defined areas in the lung having different X-Ray attenuations due to a longstanding underlying pulmonary disease From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MosaicPattern¶
A qualitative descriptor of a size that is dramatically less than typical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExtremelySmall¶
A qualitative descriptor of a size that is considerably less than typical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VerySmall¶
A qualitative descriptor of a size that is so small as to be abnormal versus expected size From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TooSmall¶
Shaped like an ellipse (oval) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Elliptic¶
A border shape that is made up of, provided with, or divided into lobules (small lobes, curved or rounded projections or divisions) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Lobulated¶
Radially orientated border shape From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Spiculated¶
The border of a shadow (opacity) is sharply defined [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SharplyDefined¶
The border of a shadow (opacity) is distinctly defined [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistinctlyDefined¶
The border of a shadow (opacity) is well distinct from adjacent structures [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WellDemarcated¶
The border of a shadow (opacity) is sharply distinct from adjacent structures [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SharplyDemarcated¶
The border of a shadow (opacity) is poorly distinct from adjacent structures [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PoorlyDemarcated¶
A shadow (opacity) possessing a complete or nearly complete visible border [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Circumscribed¶
Inspired atmospheric gas. The word is sometimes used to describe gas within the body regardless of its composition or site [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Air¶
Material having X-Ray attenuation properties similar to muscle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SoftTissue¶
Material having X-Ray attenuation properties similar to calcium, a silver- white bivalent metallic element occurring in plants and animals From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Calcium¶
A pulmonary opacity 4-8 mm in diameter, presumed to represent anatomic acinus, or a collection of opacities in the lung, each measuring 4-8 mm in diameter, and together producing an extended, homogeneous shadow [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Acinar¶
The gas-containing portion of the lung parenchyma, including the acini and excluding the interstitium [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirSpace¶
Sharply defined, approximately circular opacities occurring singly or in clusters, usually in the upper lobes [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fibronodular¶
A shadow (opacity) that is ill-defined, lacking clear-cut margins [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fluffy¶
A shadow resembling a line; any elongated opacity of approximately uniform width [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Linear¶
The number of small opacities per unit area or zone of lung. In the International Labor Organization (ILO) classification of radiographs of the pneumoconioses, the qualifiers 0 through 3 subdivide the profusion into 4 categories. The profusion categories may be further subdivided by employing a 12-point scale [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Profusion¶
The effacement of an anatomic soft tissue border by either a normal anatomic structure or a pathologic state such as airlessness of adjacent lung or accumulation of fluid in the contiguous pleural space; useful in detecting and localizing an opacity along the axis of the X-Ray beam [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SilhouetteSign¶
Situated or occurring between the pleura and the body wall From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Subpleural¶
Spatial arrangement of opacities that bears vague resemblance to the shape of a bat in flight; bilaterally symmetric [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bat_sWingDistribution¶
Spatial arrangement of opacities that bears vague resemblance to the shape of a butterfly in flight; bilaterally symmetric [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ButterflyDistribution¶
Referring to the region of the bronchioloarteriolar core of a secondary pulmonary lobule [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Centrilobular¶
The joining together of a number of opacities into a single opacity [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Coalescent¶
Of or relating to a lobe (a curved or rounded projection or division); e.g. involving an entire lobe of the lung From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Lobar¶
Extremely or excessively acute, as a qualitative measure of severity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Hyper_acute¶
Of uniform opacity or texture throughout [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Homogeneous_uniformOpacity_¶
Lack of homogeneity in opacity or texture From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Inhomogeneous¶
Discrete opacity centrally within a larger opacity, as a calcification descriptor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Target¶
Pertaining to sharply defined, linear, and/or nodular opacities containing calcification(s) [Fraser and Pare] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fibrocalcific¶
Calcifications made up of loosely aggregated particles, resembling wool From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Flocculent¶
A change in the shape formed by the boundary or edges of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInBorderShape¶
A change in the clarity of the boundary or edges of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInBorderDefinition¶
A change in the extent of spreading of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInDistribution¶
A change in the part(s) of the anatomy affected or encompassed by a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInSiteInvolvement¶
A change in the matter or substance within a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInTypeOfContent¶
A change in the surface or consistency of a finding or feature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInTexture¶
A location in image space, which may or may not correspond to an anatomical reference, which is often used for registering data sets From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FiducialMark¶
Connected to an injection chamber placed under the skin in the upper part of the chest. When it is necessary to inject some drug, a specific needle is put in the chamber through the skin and a silicon membrane. The advantage of a portacath is that it may be left in place several months contrarily of “classical” catheters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Portacath¶
A tube inserted into the chest wall from outside the body, for drainage. Sometimes used for collapsed lung. Usually connected to a receptor placed lower than the insertion site From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ChestTube¶
A tube placed into the subclavian vein to deliver medication directly into the venous system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CentralLine¶
A stent is a tube inserted into another tube. Kidney stent is a tube that is inserted into the kidney, ureter, and bladder, to help drain urine. Usually inserted through a scoping device presented through the urethra From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KidneyStent¶
A stent is a tube inserted into another tube. Pancreatic stent is inserted through the common bile duct to the pancreatic duct, to drain bile From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PancreaticStent¶
A non-lesion object that appears to be a circular band, attached to the body via pierced nipple From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NippleRing¶
A non-lesion object that appears to be a flat round piece of metal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Coin¶
The least quantity assignable, admissible, or possible; the least of a set of X-Ray attenuation coefficients From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MinimumAttenuationCoefficient¶
The greatest quantity or value attainable or attained; the largest of a set of X-Ray attenuation coefficients From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumAttenuationCoefficient¶
The value that is computed by dividing the sum of a set of X-Ray attenuation coefficients by the number of values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanAttenuationCoefficient¶
The value in an ordered set of X-Ray attenuation coefficients, below and above which there is an equal number of values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MedianAttenuationCoefficient¶
For a set of X-Ray attenuation coefficients: 1) a measure of the dispersion of a frequency distribution that is the square root of the arithmetic mean of the squares of the deviation of each of the class frequencies from the arithmetic mean of the frequency distribution; 2) a parameter that indicates the way in which a probability function or a probability density function is centered around its mean and that is equal to the square root of the moment in which the deviation from the mean is squared From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardDeviationOfAttenuationCoefficient¶
American College of Radiology. ACR Standard for the Performance of Pediatric and Adult Thoracic Computed Tomography (CT). In: Standards. Reston, Va: 2001:103-107 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformanceOfPediatricAndAdultThoracicCT¶
American College of Radiology. ACR Standard for the Performance of Computed Tomography for the Detection of Pulmonary Embolism in Adults. In: Standards. Reston, Va: 2001:109-113 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformanceOfCTForDetectionOfPulmonaryEmbolismInAdults¶
American College of Radiology. ACR Standard for the Performance of High- Resolution Computed Tomography (HRCT) of the Lungs in Adults. In: Standards. Reston, Va: 2001:115-118 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformanceOfHigh_ResolutionCTOfTheLungsInAdults¶
The method of calculation of a measurement or other type of numeric value is not specified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnspecifiedMethodOfCalculation¶
The calculation method was performed in two-dimensional space From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Two_dimensionalMethod¶
The calculation method was performed in three-dimensional space From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Three_dimensionalMethod¶
The relative density of parenchymal tissue as a proportion of breast volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastTissueDensity¶
The volume of parenchymal tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfParenchymalTissue¶
The volume of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfBreast¶
The mass of parenchymal tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassOfParenchymalTissue¶
The mass of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassOfBreast¶
A measured or calculated area of vascular calcification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOfVascularCalcification¶
A measured or calculated volume of vascular calcification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfVascularCalcification¶
A measured or calculated percentage of vascular calcification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercentageOfVascularCalcification¶
A measured or calculated mass of vascular calcification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassOfVascularCalcification¶
The average nearest neighbor distance of all individual microcalcifications in a cluster From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AverageCalcificationDistanceInACalcificationCluster¶
The standard deviation of nearest neighbor distance of all individual microcalcifications in a cluster From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardDeviationDistanceOfCalcificationsInACluster¶
A structured report containing the results of computer-aided detection or diagnosis applied to colon imaging and associated clinical information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ColonCADReport¶
Overall interpretation of the colon using C-RADS categorization system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ColonOverallAssessment¶
Characteristics of a set of images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageSetProperties¶
Nominal slice thickness, in mm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SliceThickness¶
Distance between contiguous images, measured from the center-to-center of each image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpacingBetweenSlices¶
Uniquely identifies groups of composite instances that have the same coordinate system that conveys spatial and/or temporal information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FrameOfReferenceUID¶
Patient orientation with respect to downward direction (gravity) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecumbentPatientPositionWithRespectToGravity¶
Distinguishes a part of a segmentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IdentifyingSegment¶
The diameter of a polyp stalk measured perpendicular to the axis of the stalk From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PolypStalkWidth¶
The length of the path following the centerline of the colon from the anus to the area of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceFromAnus¶
A location in the body that is outside the colon From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnatomicNon_colon¶
An inadequate study or a study that is awaiting prior comparisons. The study may have inadequate preparation and cannot exclude lesions greater than or equal to ten millimeters owing to presence of fluid or feces. The study may have inadequate insufflation where one or more colonic segments collapsed on both views. Based on “CT Colonography Reporting and Data System: A Consensus Proposal”, Radiology, July 2005; 236:3-9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C0_InadequateStudy_AwaitingPriorComparisons¶
The study has a normal colon or benign lesion, with the recommendation to continue routine screening. The study has no visible abnormalities of the colon. The study has no polyps greater than six millimeters. The study may have lipoma, inverted diverticulum, or nonneoplastic findings, such as colonic diverticula. Based on “CT Colonography Reporting and Data System: A Consensus Proposal”, Radiology, July 2005; 236:3-9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C1_NormalColonOrBenignLesion¶
The study has an intermediate polyp or indeterminate finding and surveillance or colonoscopy is recommended. There may be intermediate polyps between six and nine millimeters and there are less than three in number. The study may have an intermediate finding and cannot exclude a polyp that is greater than or equal to six millimeters in a technically adequate exam. Based on “CT Colonography Reporting and Data System: A Consensus Proposal”, Radiology, July 2005; 236:3-9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C2_IntermediatePolypOrIndeterminateFinding¶
The study has a polyp, possibly advanced adenoma, and a follow-up colonoscopy is recommended. The study has a polyp greater than or equal to ten millimeters or the study has three or more polyps that are each between six to nine millimeters. Based on “CT Colonography Reporting and Data System: A Consensus Proposal”, Radiology, July 2005; 236:3-9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C3_Polyp_PossiblyAdvancedAdenoma¶
The study has a colonic mass, likely malignant, and surgical consultation is recommended. The lesion compromises bowel lumen and demonstrates extracolonic invasion. Based on “CT Colonography Reporting and Data System: A Consensus Proposal”, Radiology, July 2005; 236:3-9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C4_ColonicMass_LikelyMalignant¶
American College of Radiology Practice Guideline for the Performance of Computed Tomography (CT) Colonography in Adults. In: Practice Guidelines and Technical Standards.Reston, Va: American College of Radiology;2006:371-376 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRGuideline_PerformanceOfAdultCTColonography¶
American College of Radiology Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment. In: Practice Guidelines and Technical Standards.Reston, Va: American College of Radiology;2006:945-948 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRStandard_CTMedicalPhysicsPerformanceMonitoring¶
View Orientation Modifier indicates that the view orientation of the imaging plane is rotated +45° along the cranial-caudal axis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AP_45¶
View Orientation Modifier indicates that the view orientation of the imaging plane is rotated -45° along the cranial-caudal axis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AP_45¶
The axis following the shaft of the femur From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnatomicalAxisOfFemur¶
Center of Rotation of the natural Acetabulum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcetabularCenterOfRotation¶
Center of Rotation of the natural femur head From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemurHeadCenterOfRotation¶
Prosthetic component implanted into the acetabulum. Provides hold for the insert that is mounted inside the cup From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcetabularCupShell¶
Prosthetic pelvic joint component. Inserted into the cup, takes in the femoral head replacement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcetabularCupInsert¶
Prosthetic pelvic joint cup including insert From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcetabularCupMonoblock¶
Component for Femoral Head Prosthesis where the conic intake for the stem neck can be exchanged. Combined with a Femoral Head Cone Taper Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralHeadBallComponent¶
Exchangeable neck intake for composite femoral head prosthesis. Combined with a Femoral Head Ball Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralHeadConeTaperComponent¶
Prosthesis Implanted into the femoral bone to provide force transmission between joint replacement and bone. On the proximal end a conic neck holds the femoral head replacement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralStem¶
Distal half of a modular stem prosthesis system. Combined with a Stem Proximal Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralStemDistalComponent¶
Proximal half of a modular stem prosthesis system. Combined with a Stem Distal Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralStemProximalComponent¶
Stem prosthetic component with a modular insert for an exchangeable neck component. Combined with a Neck Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralStemComponent¶
Prosthetic Neck to be combined with a Stem Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeckComponent¶
Prosthetic Stem and Femoral Head in one piece From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MonoblockStem¶
A proximal attachment to the shaft used to compensate for bone deficiencies or bone loss From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProstheticShaftAugment¶
Artificial femur head surface needed for the partial replacement of the femoral head where only the surface is replaced From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FemoralHeadResurfacingComponent¶
Fixation using a pin From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pinning¶
Fixation sewing several objects together From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Sewing¶
Fixation using a bolt From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bolting¶
Fixation due to forcing an object into a narrow space From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Wedging¶
Attachment to the distal end of a cemented stem assuring that the stem is in a central position inside the drilled femoral canal before cementation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistalCentralizer¶
Planning by an unspecified 2D method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Generic2DPlanning¶
Planning by an unspecified 3D method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Generic3DPlanning¶
Planning of a Hip Replacement, by an unspecified method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GenericPlanningForHipReplacement¶
Planning of Knee Replacement, by an unspecified method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GenericPlanningForKneeReplacement¶
Planning of Hip Replacement according to the procedure of M. E. Müller [Eggli et. al.1998] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- M_llerMethodPlanningForHipReplacement¶
A Report containing the results of an Implantation Planning Activity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantationPlan¶
A selection of one Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SelectedImplantComponent¶
Identification ID of an Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComponentID¶
An implant template describing the properties (2D/3D geometry and other data) of one Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantTemplate¶
A connection of two Connected Implantation Plan Components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComponentConnection¶
ID of a Mating Feature Set in an Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MatingFeatureSetID¶
ID of the Mating Feature in a Mating Feature Set in an Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MatingFeatureID¶
The Spatial Registration of one or more Implant Components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpatialRegistration¶
Patient Images used for an implantation planning activity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientImage¶
A collection of Component Connections of Implant Components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Assembly¶
Fiducials that are selected by the user and may or may not belong to anatomical landmarks From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UserSelectedFiducial¶
Fiducials that represent geometric characteristics, such as center of rotation, and are derived from other fiducials From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedFiducial¶
All parameters and data that were used for the planning activity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InformationUsedForPlanning¶
A description of the plan as encapsulated PDF SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SupportingInformation¶
A list of all Implant Components selected for an implantation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantComponentList¶
Reference to objects containing patient data that is used for planning From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDataUsedDuringPlanning¶
A specification of the values from one or more Degrees of Freedom From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreesOfFreedomSpecification¶
ID of one Degree of Freedom From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomID¶
Reference to objects containing patient data that were not used for planning but are somehow related From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelatedPatientDataNotUsedDuringPlanning¶
Implantation Reports that are somehow related; e.g. contemporaneous implantations that are independent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelatedImplantationReports¶
Implant Assembly Template From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantAssemblyTemplate¶
Information that is intended to be used intra-operatively From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlanningInformationForIntraoperativeUsage¶
Position of the patient on the operating room table From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImplantationPatientPositioning¶
Intended use of the fiducial From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FiducialIntent¶
Type of an Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComponentType¶
Implant Template released by the Manufacturer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ManufacturerImplantTemplate¶
Images that are created by a planning application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedPlanningImages¶
Data that is created by a planning application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherDerivedPlanningData¶
One Implant Component that is connected to another Implant Component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConnectedImplantationPlanComponent¶
The method used for planning From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlanningMethod¶
Defines the exact value that was planned for translation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomExactTranslationalValue¶
Defines the minimum value that was planned for translation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomMinimumTranslationalValue¶
Defines the maximum value that was planned for translation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomMaximumTranslationalValue¶
Defines the exact value that was planned for rotation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomExactRotationalTranslationValue¶
Defines the minimum value that was planned for rotation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomMinimumRotationalValue¶
Defines the maximum value that was planned for rotation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfFreedomMaximumRotationalValue¶
Procedure step protocol for photographic imaging of surgical procedures, including photography of specimens collected From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peri_operativePhotographicImaging¶
Procedure step protocol for imaging gross specimens, typically with a photographic camera (modality XC), and planning further dissection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GrossSpecimenImaging¶
Procedure step protocol for imaging slide specimens From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SlideMicroscopy¶
Procedure step protocol for imaging slide specimens using a whole slide scanner From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WholeSlideImaging¶
Procedure step protocol for imaging slide specimens using a whole slide scanner with a 20X nominal objective lens, in full color, with a single imaging focal plane across the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WSI20XRGB¶
Procedure step protocol for imaging slide specimens using a whole slide scanner with a 40X nominal objective lens, in full color, with a single imaging focal plane across the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WSI40XRGB¶
Technique of illuminating specimen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IlluminationMethod¶
Number of focal planes for a microscopy image acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfFocalPlanes¶
Nominal distance above a reference plane (typically a slide glass substrate top surface) of the focal plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FocalPlaneZOffset¶
Microscope magnification based on nominal objective lens power From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MagnificationSelection¶
Nominal center wavelength for an imaging spectral band From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IlluminationWavelength¶
Name (coded) for an imaging spectral band From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IlluminationSpectralBand¶
Type of filter inserted into the optical imaging path From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OpticalFilterType¶
Technique for identifying tissue to be imaged versus area of slide not to be imaged From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TissueSelectionMethod¶
Imaging performed at multiple imaging (focal) planes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultiplePlanes¶
Nominal 5 power objective lens, resulting in a digital image at approximately 2 um/pixel spacing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NominalEmptyTileSuppression¶
Equipment-specific high threshold method for identifying tiles without tissue imaged for suppression from inclusion in image object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HighThresholdEmptyTileSuppression¶
Tiles without tissue imaged are not suppressed from inclusion in image object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoEmptyTileSuppression¶
Of Interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OfInterest¶
Rejected for Quality Reasons From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RejectedForQualityReasons¶
For Referring Provider From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForReferringProvider¶
For Surgery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForSurgery¶
For Teaching From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForTeaching¶
For Conference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForConference¶
For Therapy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForTherapy¶
For Patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForPatient¶
For Peer Review From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForPeerReview¶
For Research From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForResearch¶
Quality Issue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityIssue¶
Document Title Modifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DocumentTitleModifier¶
Key Object Description From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KeyObjectDescription¶
A selection that represents the “best” chosen from a larger set of items; e.g. the best images within a Study or Series. The criteria against which “best” is measured is not defined. Contrast this with the more specific term “Best illustration of finding” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BestInSet¶
A study is a collection of one or more series of medical images, presentation states, and/or SR documents that are logically related for the purpose of diagnosing a patient. A study may include composite instances that are created by a single modality, multiple modalities or by multiple devices of the same modality. [From Section A.1.2.2 “Study IE” in PS3.3 ] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Study¶
A distinct logical set used to group composite instances. All instances within a Series are of the same modality, in the same Frame of Reference (if any), and created by the same equipment. [See Section A.1.2.3 “Series IE” in PS3.3 ] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Series¶
An arbitrarily defined unit of service that has actually been performed (not just scheduled). [From Section 7.3.1.9 “Modality Performed Procedure Step” in PS3.3 ] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformedProcedureStep¶
An image or set of images illustrating a specific stage (phase in a stress echo exam protocol) and view (combination of the transducer position and orientation at the time of image acquisition) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Stage_View¶
For Printing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForPrinting¶
Selection of information objects for attachment to the clinical report of the Current Requested Procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForReportAttachment¶
List of objects that are related to litigation and should be specially handled; e.g. may apply if a complaint has been received regarding a patient, or a specific set of images has been the subject of a subpoena, and needs to be sequestered or excluded from automatic purging according to retention policy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForLitigation¶
Double exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoubleExposure¶
A list of objects that have been exported out of one organizational domain into another domain. Typically, the first domain has no direct control over what the second domain will do with the objects From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Manifest¶
A signed list of objects that have been exported out of one organizational domain into another domain, referenced securely with either Digital Signatures or MACs. Typically, the first domain has no direct control over what the second domain will do with the objects From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignedManifest¶
The list of objects that constitute a study at the time that the list was created From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompleteStudyContent¶
The signed list of objects that constitute a study at the time that the list was created, referenced securely with either Digital Signatures or MACs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignedCompleteStudyContent¶
The list of objects that were generated in a single procedure step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompleteAcquisitionContent¶
The signed list of objects that were generated in a single procedure step, referenced securely with either Digital Signatures or MACs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignedCompleteAcquisitionContent¶
A list of frames or single-frame or entire multi-frame instances that together constitute a set for some purpose, such as might be displayed together in the same viewport, as distinct from another set that might be displayed in a separate viewport From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GroupOfFramesForDisplay¶
List of objects whose use is potentially harmful to the patient; e.g. an improperly labeled image could lead to dangerous surgical decisions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RejectedForPatientSafetyReasons¶
List of objects that were acquired using an incorrect modality worklist entry, and that should not be used, since they may be incorrectly identified From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IncorrectModalityWorklistEntry¶
List of objects that have expired according to a defined data retention policy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DataRetentionPolicyExpired¶
Lossy compression has been applied to an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LossyCompression¶
Values are derived by calculation of the apparent diffusion coefficient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ApparentDiffusionCoefficient¶
Values are derived by the pixel by pixel addition of two images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelAddition¶
Values are derived by calculation of the diffusion weighting From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiffusionWeighted¶
Values are derived by calculation of the diffusion anisotropy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiffusionAnisotropy¶
Values are derived by calculation of the diffusion attenuation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiffusionAttenuated¶
Values are derived by the pixel by pixel division of two images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelDivision¶
Values are derived by the pixel by pixel masking of one image by another From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelMask¶
Values are derived by calculating the pixel by pixel maximum of two or more images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelMaximum¶
Values are derived by calculating the pixel by pixel mean of two or more images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelMean¶
Values are derived by calculating from spectroscopy data pixel values localized in two dimensional space based on the concentration of specific metabolites (i.e, at specific frequencies) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetaboliteMapsFromSpectroscopyData¶
Values are derived by calculating the pixel by pixel minimum of two or more images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelMinimum¶
The time required for blood to pass through a region of tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanTransitTime¶
Values are derived by the pixel by pixel multiplication of two images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelMultiplication¶
Values are derived by calculating negative enhancement integral values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NegativeEnhancementIntegral¶
The flow rate of blood perfusing a region of the brain as volume per mass per unit of time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalCerebralBloodFlow¶
The volume of blood perfusing a region of brain as volume per mass From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalCerebralBloodVolume¶
Correlation Coefficient, r From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R_Coefficient¶
Values are derived by calculating proton density values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProtonDensity¶
Values are derived by calculating signal change values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalChange¶
Values are derived by calculating the signal to noise ratio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalToNoise¶
Values are derived by calculating the standard deviation of two or more images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardDeviation¶
Values are derived by the pixel by pixel subtraction of two images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelByPixelSubtraction¶
Values are derived by calculating T1 values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1¶
Values are derived by calculating T2* values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2_¶
Values are derived by calculating T2 values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T2¶
Values are derived by calculating values based on the time course of signal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeCourseOfSignal¶
Values are derived by calculating values based on temperature encoding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TemperatureEncoded¶
Values are derived by calculating the value of the Student’s T-Test statistic from multiple image samples From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Student_sT_Test¶
The time from the start of the contrast agent injection to the maximum enhancement value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeToPeak¶
Values are derived by calculating values based on velocity encoded; e.g. phase contrast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VelocityEncoded¶
Values are derived by calculating the value of the Z-Score statistic from multiple image samples From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Z_Score¶
Values are derived by reformatting in a flat plane other than that originally acquired From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultiplanarReformatting¶
Values are derived by reformatting in a curve plane other than that originally acquired From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurvedMultiplanarReformatting¶
Values are derived by volume rendering of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeRendering¶
Values are derived by surface rendering of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SurfaceRendering¶
Values are derived by segmentation (classification into tissue types) of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Segmentation¶
Values are derived by selectively editing acquired data (removing values from the volume), such as in order to remove obscuring structures or noise From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeEditing¶
Values are derived by maximum intensity projection of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumIntensityProjection¶
Values are derived by minimum intensity projection of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MinimumIntensityProjection¶
For single-proton MR spectroscopy, the resonance peak corresponding to glutamate and glutamine From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlutamateAndGlutamine¶
For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peaks From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Choline_CreatineRatio¶
For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Creatine resonance peaks From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- N_acetylaspartate_CreatineRatio¶
For single-proton MR spectroscopy, the ratio between the N-acetylaspartate and Choline resonance peaks From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- N_acetylaspartate_CholineRatio¶
Values are derived by spatial resampling of acquired data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpatialResampling¶
Values are derived by edge enhancement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EdgeEnhancement¶
Values are derived by smoothing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Smoothing¶
Values are derived by Gaussian blurring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GaussianBlur¶
Values are derived by unsharp masking From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnsharpMask¶
Values are derived by stitching two or more images together From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageStitching¶
Spatially-related frames in this image are representative frames from the referenced 3D volume data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
Temporally-related frames in this image are representative frames from the referenced 3D volume data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
Conversion of a polar coordinate image to rectangular (Cartesian) coordinate image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PolarToRectangularScanConversion¶
For single-proton MR spectroscopy, the resonance peak corresponding to creatine and choline From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CreatineAndCholine¶
For single-proton MR spectroscopy, the resonance peak corresponding to lipid and lactate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LipidAndLactate¶
For single-proton MR spectroscopy, the ratio between the Choline and Creatine resonance peak and the Citrate resonance peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Creatine_Choline_CitrateRatio¶
Image pixels created through proportional weighting of multiple acquisitions at distinct X-Ray energies From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Multi_energyProportionalWeighting¶
De-identification using a profile defined in PS3.15 that requires removing all information related to the identity and demographic characteristics of the patient, any responsible parties or family members, any personnel involved in the procedure, the organizations involved in ordering or performing the procedure, additional information that could be used to match instances if given access to the originals, such as UIDs, dates and times, and private attributes, when that information is present in the non-Pixel Data Attributes, including graphics or overlays From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BasicApplicationConfidentialityProfile¶
Additional de-identification according to an option defined in PS3.15 that requires any information burned in to the Pixel Data corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CleanPixelDataOption¶
Additional de-identification according to an option defined in PS3.15 that requires that sufficient removal or distortion of the Pixel Data shall be applied to prevent recognition of an individual from the instances themselves or a reconstruction of a set of instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CleanRecognizableVisualFeaturesOption¶
Additional de-identification according to an option defined in PS3.15 that requires that any information encoded in graphics, text annotations or overlays corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CleanGraphicsOption¶
Additional de-identification according to an option defined in PS3.15 that requires that any information encoded in SR Content Items or Acquisition Context Sequence Items corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CleanStructuredContentOption¶
Additional de-identification according to an option defined in PS3.15 that requires that any information that is embedded in text or string Attributes corresponding to the Attribute information specified to be removed by the Profile and any other Options specified also be removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CleanDescriptorsOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that any dates and times be retained, From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainLongitudinalTemporalInformationFullDatesOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that any dates and times be modified in a manner that preserves temporal relationships; e.g. Study Date and Time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainLongitudinalTemporalInformationModifiedDatesOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that any physical characteristics of the patient, which are descriptive rather than identifying information per se, be retained; e.g. Patient’s Age, Sex, Size (height) and Weight From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainPatientCharacteristicsOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that any information that identifies a device be retained; e.g. Device Serial Number From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainDeviceIdentityOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that UIDs be retained; e.g. SOP Instance UID From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainUIDsOption¶
Retention of information that would otherwise be removed during de- identification according to an option defined in PS3.15 that requires that private attributes that are known not to contain identity information be retained; e.g. private SUV scale factor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RetainSafePrivateOption¶
The procedure report is a Radiopharmaceutical Radiation Dose report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalRadiationDoseReport¶
Information pertaining to the administration of a radiopharmaceutical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalAdministration¶
Unique identification of a single radiopharmaceutical administration event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalAdministrationEventUID¶
Initial signs or symptoms of extravasation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntravenousExtravasationSymptoms¶
The estimated percentage of administered activity lost at the injection site. The estimation includes extravasation, paravenous administration and leakage at the injection site From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EstimatedExtravasationActivity¶
The calculated activity at the Radiopharmaceutical Start Time when the radiopharmaceutical is administered to the patient. The residual activity (i.e. radiopharmaceutical not administered) , if measured, is reflected in the calculated value. The estimated extravasation is not reflected in the calculated value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdministeredActivity¶
Radioactivity measurement of radiopharmaceutical before or during the administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pre_AdministrationMeasuredActivity¶
Radioactivity measurement of radiopharmaceutical after the administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Post_AdministrationMeasuredActivity¶
Registered drug establishment code for product, coding scheme example is NDC or RxNorm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DrugProductIdentifier¶
The human readable identification of the specific radiopharmaceutical dispensed quantity or dose (“dose” as unit of medication delivery, not radiation dose measure) to be administered to the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalDispenseUnitIdentifier¶
Identifies the vial, batch or lot number from which the individual dispense radiopharmaceutical quantity (dose) is produced. The Radiopharmaceutical Dispense Unit Identifier records the identification for each individual dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalLotIdentifier¶
Identifies the lot or unit serial number for the reagent component for the radiopharmaceutical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReagentVialIdentifier¶
Identifies the lot or unit serial number for the radionuclide component for the radiopharmaceutical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadionuclideVialIdentifier¶
Administered Product’s Prescription Number From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PrescriptionIdentifier¶
Information pertaining to the estimated absorbed radiation dose to an organ From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrganDoseInformation¶
The absorbed radiation dose to organ From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrganDose¶
Reference authority MIRD Pamphlet No.1 (rev) ,Society of Nuclear Medicine, 1976 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MIRDPamphlet1¶
Reference authority ICRP, 1988. Radiation Dose to Patients from Radiopharmaceuticals. ICRP Publication 53. Ann. ICRP 18 (1-4) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ICRPPublication53¶
Reference authority ICRP, 1998. Radiation Dose to Patients from Radiopharmaceuticals (Addendum to ICRP Publication 53). ICRP Publication 80. Ann. ICRP 28 (3) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ICRPPublication80¶
Reference authority ICRP, 2008. Radiation Dose to Patients from Radiopharmaceuticals - Addendum 3 to ICRP Publication 53. ICRP Publication 106. Ann. ICRP 38 (1-2) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ICRPPublication106¶
Reference authority Stabin MG, Sparks RB, Crowe E (1994) MIRDOSE: personal computer software for internal dose assessment in nuclear medicine [Computer program] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MIRDOSE¶
Reference authority Stabin MG, Sparks RB, Crowe E (2005) OLINDA/EXM: The Second-Generation Personal Computer Software for Internal Dose Assessment in Nuclear Medicine [Computer program] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OLINDA_EXM¶
Reference authority The reported organ dose is based on radiopharmaceutical’s package insert From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PackageInsert¶
Reference authority The reported organ dose is based on Institutionally approved estimates from the Radioactive Drug Research Committee (RDRC) of the institution itself From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InstitutionallyApprovedEstimates¶
Reference authority The reported organ dose is based on an Investigation new drug From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InvestigationalNewDrug¶
The type of device that performed the activity measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ActivityMeasurementDevice¶
The device that measures the radiation activity of the radiopharmaceutical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseCalibrator¶
Radiopharmaceutical Infusion System From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InfusionSystem¶
Radioisotope Generator From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Generator¶
The number hours the patient has gone without food From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FastingDuration¶
The amount of fluids the patient has consumed before the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HydrationVolume¶
A description of physical activity the patient performed before the start of the procedure, such as that which may affect imaging agent biodistribution From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RecentPhysicalActivity¶
Blockage in one of the tubes (ureters) that drain urine from the kidneys From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcuteUnilateralRenalBlockage¶
5% or less Thyroid Uptake of Iodine From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LowThyroidUptake¶
25% or higher Thyroid Uptake of Iodine From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HighThyroidUptake¶
The patient exhibits symptoms severe of jaundice and/or has a Bilirubin >10 mg/dL From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeverelyJaundiced¶
Extravasation or paravenous administration of the product is visible in the images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExtravasationVisibleInImage¶
The measurement method of the Glomerular Filtration Rate is Cockroft-Gault Formula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cockroft_GaultFormulaEstimationOfGFR¶
The measurement method of the Glomerular Filtration Rate is CKD-EPI Formula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CKD_EPIFormulaEstimationOfGFR¶
The measurement method of the Glomerular Filtration Rate is MDRD From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRate_MDRD_¶
The measurement method of the Glomerular Filtration Rate is non-black MDRD From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRateNon_black_MDRD_¶
The measurement method of the Glomerular Filtration Rate is black (MDRD) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRateBlack_MDRD_¶
The measurement method of the Glomerular Filtration Rate is female (MDRD) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRateFemale_MDRD_¶
The measurement method of the Glomerular Filtration Rate is Cystatin-based formula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRateCystatin_basedFormula¶
The measurement method of the Glomerular Filtration Rate is Creatinine-based formula (Schwartz) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlomerularFiltrationRateCreatinine_basedFormula_Schwartz_¶
Small body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Small_32_0CmLateralThickness¶
Medium body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Medium_32_0_38_0CmLateralThickness¶
Large body thickness for calcium scoring adjustment. Lateral thickness is measured from skin-to-skin, at the level of the proximal ascending aorta, from an A/P localizer image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Large_38_0CmLateralThickness¶
A human-readable label identifying an irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEventLabel¶
The type of a human-readable label From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LabelType¶
A number that identifies a Series. Corresponds to (0020,0011) in PS3.3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeriesNumber¶
A number that identifies an Acquisition. Corresponds to (0020,0012) in PS3.3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionNumber¶
A number that identifies an Instance. Corresponds to (0020,0013) in PS3.3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InstanceNumber¶
Acquisition where the X-Ray source does not move in relation to the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StationaryAcquisition¶
Acquisition where the X-Ray source moves laterally in relation to the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SteppingAcquisition¶
Acquisition where the X-Ray source moves angularly in relation to the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RotationalAcquisition¶
Primary plane of a Biplane acquisition equipment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaneA¶
Secondary plane of a Biplane acquisition equipment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaneB¶
Single plane acquisition equipment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SinglePlane¶
Continuous X-Ray radiation is applied during an irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Continuous¶
Pulsed X-Ray radiation is applied during an irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pulsed¶
Filter with uniform thickness From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StripFilter¶
Filter with variation in thickness from one edge to the opposite edge From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WedgeFilter¶
Filter with two triangular sections From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ButterflyFilter¶
Filter with uniform thickness that is for spectral filtering only; e.g. filter out low energy portion of the X-Ray that would only contribute to skin dose, but not to image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlatFilter¶
A polyline defining the outline of a lobulated finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OutlineOfLobulations¶
A polyline defining the inner limits of a finding with fuzzy margin From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InnerLimitsOfFuzzyMargin¶
A polyline defining the outer limits of a finding with fuzzy margin From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OuterLimitsOfFuzzyMargin¶
A polyline defining the outline of the spiculations of a finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OutlineOfSpiculations¶
A polyline segment graphically indicating the location and direction of a spiculation of a finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LinearSpiculation¶
A collection of points indicating the pixel locations of the spiculations of a finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PixelatedSpiculations¶
Connected line segments indicating the center of location of a finding on an orthogonal view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrthogonalLocationArc¶
Connected line segments indicating the inner margin of the location of a finding on an orthogonal view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrthogonalLocationArcInnerMargin¶
Connected line segments indicating the outer location of a finding on an orthogonal view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrthogonalLocationArcOuterMargin¶
This procedure is intended to gather data that is used for calibration or other quality control purposes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualityControlIntent¶
An artificial subject of an imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Phantom¶
A phantom acceptable for the ACR Computed Tomography Accreditation program From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_CT¶
A phantom acceptable for the ACR Magnetic Resonance Imaging Accreditation program From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_MR¶
A phantom acceptable for the ACR Mammography Accreditation program From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_Mammography¶
A phantom acceptable for the ACR Stereotactic Breast Biopsy Accreditation program From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_StereotacticBreastBiopsy¶
A phantom acceptable for the ACR SPECT Accreditation program (but not for PET) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_ECT¶
A phantom acceptable for the ACR PET Accreditation program (but not for SPECT) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_PET¶
A SPECT phantom with a PET faceplate acceptable for both the ACR SPECT and PET Accreditation programs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_ECT_PET¶
A PET faceplate (made to fit an existing flangeless or flanged ECT phantom) acceptable for the ACR PET Accreditation program From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ACRAccreditationPhantom_PETFaceplate¶
A phantom used for CTDI measurement in head modes according to IEC 60601-2-44, Ed.2.1 (Head 16 cm diameter Polymethyl methacrylate PMMA) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IECHeadDosimetryPhantom¶
A phantom used for CTDI measurement in body modes according to IEC 60601-2-44, Ed.2.1 (Body 32cm diameter Polymethyl methacrylate PMMA) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IECBodyDosimetryPhantom¶
A phantom in accordance with NEMA standard XR-21-2000 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NEMAXR21_2000Phantom¶
X-Ray Radiation Dose Report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayRadiationDoseReport¶
X-Ray dose data accumulated over multiple irradiation events; e.g. for a study or a performed procedure step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AccumulatedX_RayDoseData¶
Imaging using a point X-Ray source with a diverging beam projected onto a 2 dimensional detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProjectionX_Ray¶
Entity over which dose accumulation values are integrated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScopeOfAccumulation¶
X-Ray dose data for a single Irradiation Event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEventX_RayData¶
Material containing Niobium or a Niobium compound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NiobiumOrNiobiumCompound¶
Material containing Europium or a Europium compound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EuropiumOrEuropiumCompound¶
Describes the method used to derive the calibration factor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationProtocol¶
Denotes the type of irradiation event recorded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEventType¶
Total calculated Dose Area Product (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseAreaProductTotal¶
Last calibration Date for the integrated dose meter or dose calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationDate¶
Individual or organization responsible for calibration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationResponsibleParty¶
Total Dose related to Reference Point (RP). (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Dose_RP_Total¶
Total calculated Dose Area Product applied in Fluoroscopy Modes (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluoroDoseAreaProductTotal¶
Total calculated Dose Area Product applied in Acquisition Modes (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDoseAreaProductTotal¶
Dose applied in Fluoroscopy Modes, related to Reference Point (RP). (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluoroDose_RP_Total¶
Dose applied in Acquisition Modes, related to Reference Point (RP). (in the scope of the including report) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDose_RP_Total¶
Total accumulated clock time of Fluoroscopy in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated fluoroscopy irradiation events) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalFluoroTime¶
Accumulated Count of exposure pulses (single or multi-frame encoded) created from irradiation events performed with high dose (acquisition) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalNumberOfRadiographicFrames¶
Mode of application of X-Rays during Fluoroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluoroMode¶
Applied X-Ray Tube voltage at peak of X-Ray generation, in kilovolts; Mean value if measured over multiple peaks (pulses) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KVP¶
Mean value of applied Tube Current From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayTubeCurrent¶
Cumulative time the patient has received X-Ray exposure during the irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExposureTime¶
Mean value of X-Ray Current Time product From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Exposure¶
Distance to the Reference Point (RP) defined according to IEC 60601-2-43 or equipment defined From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceSourceToReferencePoint¶
Dose applied at the Reference Point (RP) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Dose_RP_¶
Positioner Primary Angle at the end of an irradiation event. For further definition see (112011, DCM, “Positioner Primary Angle”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionerPrimaryEndAngle¶
Positioner Secondary Angle at the end of an irradiation event. For further definition see (112012, DCM, “Positioner Secondary Angle”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionerSecondaryEndAngle¶
Clock time from the start of loading time of the first pulse until the loading time trailing edge of the final pulse in the same irradiation event. Note Loading time is defined in IEC 60601-1-3:2008, 3.37, and described in IEC 60601-2-54:2009, 203.4.101.3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationDuration¶
Orientation of the Patient with respect to Gravity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientOrientation¶
Enhances or modifies the Patient orientation specified in Patient Orientation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientOrientationModifier¶
Orientation of the Patient with respect to the Head of the Table From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTableRelationship¶
Distance from the X-Ray Source to the Equipment C-Arm Isocenter.(Center of Rotation) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceSourceToIsocenter¶
Measured or calculated distance from the X-Ray source to the detector plane in the center of the beam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceSourceToDetector¶
Table Longitudinal Position with respect to an arbitrary chosen reference by the equipment. Table motion towards LAO is positive assuming that the patient is positioned supine and its head is in normal position From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableLongitudinalPosition¶
Table Lateral Position with respect to an arbitrary chosen reference by the equipment. Table motion towards CRA is positive assuming that the patient is positioned supine and its head is in normal position From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableLateralPosition¶
Table Height Position with respect to an arbitrary chosen reference by the equipment in (mm). Table motion downwards is positive From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableHeightPosition¶
Angle of the head-feet axis of the table in degrees relative to the horizontal plane. Positive values indicate that the head of the table is upwards From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableHeadTiltAngle¶
Rotation of the table in the horizontal plane (clockwise when looking from above the table) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableHorizontalRotationAngle¶
Angle of the left-right axis of the table in degrees relative to the horizontal plane. Positive values indicate that the left of the table is upwards From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableCradleTiltAngle¶
X-Ray absorbing material used in the filter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilterMaterial¶
The minimum thickness of the X-Ray absorbing material used in the filters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilterThicknessMinimum¶
Table Longitudinal Position at the end of an irradiation event; see (113751, DCM, “Table Longitudinal Position”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableLongitudinalEndPosition¶
Table Lateral Position at the end of an irradiation event; see (113752, DCM, “Table Lateral Position”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableLateralEndPosition¶
Table Height Position at the end of an irradiation event; see (113753, DCM, “Table Height Position”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableHeightEndPosition¶
Uncertainty of the ‘actual’ value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationUncertainty¶
Identification of Acquisition Plane with Biplane systems From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionPlane¶
Nominal Size of Focal Spot of X-Ray Tube From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FocalSpotSize¶
Average X-Ray Tube Current averaged over time for pulse or for continuous Fluoroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AverageX_RayTubeCurrent¶
Number of pulses applied by X-Ray systems during an irradiation event (acquisition run or pulsed fluoro) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfPulses¶
Unique identification of a single irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEventUID¶
Angle of the X-Ray beam in degree relative to an orthogonal axis to the detector plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ColumnAngulation¶
Devices used to modify the energy or energy distribution of X-Rays From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilters¶
Type of filter(s) inserted into the X-Ray beam; e.g. wedges From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilterType¶
The maximum thickness of the X-Ray absorbing material used in the filters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilterThicknessMaximum¶
System provided definition of the Reference Point used for Dose calculations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencePointDefinition¶
Distance between the collimator blades in pixel column direction as projected at the detector plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CollimatedFieldHeight¶
Distance between the collimator blades in pixel row direction as projected at the detector plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CollimatedFieldWidth¶
Collimated field area at image receptor. Area for compatibility with IEC 60601-2-43 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CollimatedFieldArea¶
Pulse rate applied by equipment during Fluoroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulseRate¶
Measured or calculated distance from the X-Ray source to the table plane in the center of the beam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceSourceToTablePlane¶
(Average) X-Ray pulse width From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulseWidth¶
Calibrated device to perform dose measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseMeasurementDevice¶
Image acquired during a specified event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquiredImage¶
Effective Dose evaluation from the product of Dose Length Product (DLP) and the Effective Dose Conversion Factor (E/DLP in units of mSv/mGy-cm), where the ratio is derived by means of Monte Carlo computations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPToEConversionViaMCComputation¶
Effective Dose evaluation from the product of the Mean CTDIfreeair and the ratio E/CTDIfreeair (mSv/mGy), where the ratio is derived by means of Monte Carlo computations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIfreeairToEConversionViaMCComputation¶
Effective Dose evaluation from the product of Dose Length Product (DLP) and the Effective Dose Conversion Factor (E/DLP in units of mSv/mGy-cm), where the ratio is derived by means of dosimetric measurements with an anthropomorphic phantom From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPToEConversionViaMeasurement¶
Effective Dose evaluation from the product of the Mean CTDIfreeair and the ratio E/CTDIfreeair (mSv/mGy), where the ratio is derived by means of dosimetric measurements with an anthropomorphic phantom From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIfreeairToEConversionViaMeasurement¶
The CT acquisition was performed by acquiring single or multi detector data while rotating the source about the gantry while the table is not moving. Additional slices are acquired by incrementing the table position and again rotating the source about the gantry while the table is not moving From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SequencedAcquisition¶
The CT acquisition was performed by holding the source at a constant angle and moving the table to obtain a projection image; e.g. localizer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConstantAngleAcquisition¶
The CT acquisition was performed by holding the table at a constant position and acquiring multiple slices over time at the same location From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StationaryAcquisition¶
The CT acquisition was performed while rotating the source about the gantry while the table movement is under direct control of a human operator or under the control of an analysis application; e.g. fluoro From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FreeAcquisition¶
Reference authority 1990 Recommendations of the International Commission on Radiological Protection (ICRP Publication 60, published as the Annals of the ICRP Vol. 21, No. 1-3, Pergamon Press,1991) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ICRPPub60¶
Start, DateTime of the first X-Ray Irradiation Event of the accumulation within a Study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfX_RayIrradiation¶
End, DateTime of the last X-Ray Irradiation Event of the accumulation within a Study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndOfX_RayIrradiation¶
X-Ray dose accumulated over multiple CT irradiation events; e.g. for a study or a performed procedure step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTAccumulatedDoseData¶
Total number of events during the defined scope of accumulation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalNumberOfIrradiationEvents¶
The total dose length product defined scope of accumulation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDoseLengthProductTotal¶
The total Effective Dose at the defined scope of accumulation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTEffectiveDoseTotal¶
Identification of the reference-patient model used when Effective Dose is evaluated via Monte Carlo calculations or from a Dose Length Product conversion factor based on Monte Carlo calculations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientModel¶
References the physical phantom and the type of dosimeter used when measurements are done to establish Effective Dose Conversion Factors (E/DLP) or ratios E/CTDIfreeair From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConditionEffectiveDoseMeasured¶
Type of Effective Dose phantom used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EffectiveDosePhantomType¶
Type of dosimeter used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DosimeterType¶
General description of the CT Irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTAcquisition¶
Method of the CT acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTAcquisitionType¶
Thickness of an equivalent filter in mm in Aluminum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayFilterAluminumEquivalent¶
General description of the acquisition parameters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTAcquisitionParameters¶
Number of X-Ray sources From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfX_RaySources¶
Total time the patient has received X-Ray exposure during the irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExposureTime¶
Length of the table travel during the entire tube loading, according to IEC 60601-2-44 Note Scanning Length might be longer than the programmed acquisition length (Length of Reconstructable Volume) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScanningLength¶
The value of the nominal width referenced to the location of the isocenter along the z axis of a single row of acquired data in mm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NominalSingleCollimationWidth¶
The value of the nominal width referenced to the location of the isocenter along the z axis of the total collimation in mm over the area of active X-Ray detection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NominalTotalCollimationWidth¶
For Spiral scanning: Pitch Factor = (Table Feed per Rotation (mm)) /(Nominal Total Collimation Width (mm)) For Sequenced scanning: Pitch Factor = (Table Feed per single Sequenced scan (mm)) /(Nominal Total Collimation Width (mm)) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PitchFactor¶
General description of CT dose values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDose¶
“Mean CTDIvol” refers to the average value of the CTDIvol associated with this acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanCTDIvol¶
Identification, tube-potential, tube-current, and exposure-time parameters associated with an X-Ray source during an acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTX_RaySourceParameters¶
Identifies the particular X-Ray source (in a multi-source CT system) for which the set of X-Ray source parameter values is reported From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IdentificationOfTheX_RaySource¶
Maximum X-Ray tube current From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumX_RayTubeCurrent¶
The exposure time for one rotation of the source around the object in s From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExposureTimePerRotation¶
A label describing the type of phantom used for CTDIW measurement according to IEC 60601-2-44 (Head 16 cm diameter PMMA, Body 32 cm diameter PMMA) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIwPhantomType¶
The CTDIfreeair Calculation Factor is the CTDIfreeair per mAs, expressed in units of mGy/mAs. The CTDIfreeair Calculation Factor may be used in one method calculating Dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIfreeairCalculationFactor¶
The average value of the free-in-air CTDI associated with this acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanCTDIfreeair¶
Dose Length Product (DLP), expressed in mGy-cm, is an index characterizing the product of the CTDIvol and the length scanned. For Spiral scanning, DLP = CTDIvol x Scanning Length. For Sequenced scanning, DLP = CTDIvol x Nominal Total Collimation Width x Cumulative Exposure Time / Exposure Time per Rotation. For Stationary and Free scanning, DLP = CTDIvol x Nominal Total Collimation Width From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLP¶
Effective dose in mSv From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EffectiveDose¶
Effective Dose per DLP, reference value for Effective Dose calculation, expressed in mSv/mGY.cm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EffectiveDoseConversionFactor¶
Effective Dose Reference authority 2007 Recommendations of the International Commission on Radiological Protection (ICRP Publication 103, published as the Annals of the ICRP Vol. 37, No. 2-4, Elsevier, 2007) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ICRPPub103¶
The type of exposure modulation used for the purpose of limiting the dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayModulationType¶
Measure of the detector response to radiation in the relevant image region of an image acquired with a digital X-Ray imaging system as defined in IEC 62494-1; see PS3.3 definition of Exposure Index Macro From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExposureIndex¶
The target value used to calculate the Deviation Index as defined in IEC 62494-1; see PS3.3 definition of Exposure Index Macro From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetExposureIndex¶
A scaled representation of the accuracy of the Exposure Index compared to the Target Exposure Index as defined in IEC 62494-1; see PS3.3 definition of Exposure Index Macro From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviationIndex¶
The clinician responsible for determining that the irradiating procedure was appropriate for the indications From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationAuthorizing¶
The person responsible for the administration of radiation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationAdministering¶
An irradiation event is the loading of X-Ray equipment caused by a single continuous actuation of the equipment’s irradiation switch, from the start of the loading time of the first pulse until the loading time trailing edge of the final pulse. Any automatic on-off switching of the irradiation source during the event is not treated as separate events, rather the event includes the time between start and stop of irradiation as triggered by the user; e.g. a pulsed fluoro X-Ray acquisition shall be treated as a single irradiation event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEvent¶
Unique Identifier of an Irradiation Event From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiationEventUID¶
Method by which dose-related details of an Irradiation Event were obtained From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceOfDoseInformation¶
Total accumulated acquisition clock time in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated acquisition irradiation events) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalAcquisitionTime¶
Direct recording of data by a relevant system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AutomatedDataCollection¶
Recording of data by a human operator, including manual transcription of electronic data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ManualEntry¶
The data is taken from an MPPS SOP Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MPPSContent¶
A device exposing a patient to ionizing radiation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IrradiatingDevice¶
15cm from the isocenter towards the X-Ray source; See IEC 60601-2-43 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EntranceExposureToA4_2CmBreastThickness¶
The data is copied from information present in the image attributes; e.g. dose attributes such as CTDIvol (0018,9345) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CopiedFromImageAttributes¶
The data is computed from information present in the image attributes; e.g. by using dosimetry information for the specific irradiating device make and model, applied to technique information such as KVP and mAs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComputedFromImageAttributes¶
The data is derived from human-readable reports; e.g. by natural language parsing of text reports, or optical character recognition from reports saved as images by the irradiating device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedFromHuman_ReadableReports¶
The name of a specific person From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonName¶
An identification number or code for a specific person From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonID¶
The organization that issued a Person ID From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonIDIssuer¶
The name of an organization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OrganizationName¶
The role played by a person in an organization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonRoleInOrganization¶
The role played by a person in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonRoleInProcedure¶
The role played by a device in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceRoleInProcedure¶
The name used to refer to a device; usually locally unique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceName¶
Manufacturer of a device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceManufacturer¶
Model Name of a device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceModelName¶
Serial Number of a device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSerialNumber¶
All planes of a multi-plane acquisition equipment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AllPlanes¶
The length from which images may be reconstructed (i.e., excluding any overranging performed in a spiral acquisition that is required for data interpolation). Value is distinct from (1113825, DCM, “Scanning Length”), which is the actual length of the table travel during the entire tube loading, according to IEC 60601-2-44, and includes overranging. Also distinct from any actual Reconstructed Volume, which may depend on the slice thickness chosen for a particular reconstruction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LengthOfReconstructableVolume¶
The Z location that is the top (highest Z value) of the Reconstructable Volume. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TopZLocationOfReconstructableVolume¶
The Z location that is the bottom (lowest Z value) of the Reconstructable Volume. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BottomZLocationOfReconstructableVolume¶
The Z location that is the top (highest Z value) of the scanning length. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TopZLocationOfScanningLength¶
The Z location that is the bottom (lowest Z value) of the scanning length. Specified as the Z component within the Patient Coordinate System defined by a specified Frame of Reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BottomZLocationOfScanningLength¶
The range along the z axis of the total volume irradiated, per IEC 60601-2-44, Ed. 3, 203.115(b). The start and stop of loading corresponding to the outer edge of the full width half maximum of the free-in-air dose profile for the beam collimation used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExposedRange¶
Report section about cumulative dose alerts during an examination From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseCheckAlertDetails¶
Flag denoting whether a DLP Alert Value was configured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPAlertValueConfigured¶
Flag denoting whether a CTDIvol Alert Value was configured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIvolAlertValueConfigured¶
Cumulative Dose Length Product value configured to trigger an alert; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPAlertValue¶
Cumulative CTDIvol value configured to trigger an alert; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIvolAlertValue¶
A forward estimate of the accumulated DLP plus the estimated DLP for the next Protocol Element Group; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AccumulatedDLPForwardEstimate¶
A forward estimate at a given location of the accumulated CTDIvol plus the estimated CTDIvol for the next Protocol Element Group; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AccumulatedCTDIvolForwardEstimate¶
Reason provided for proceeding with a procedure that is projected to exceed a configured dose value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReasonForProceeding¶
Report section about dose notifications during a protocol element From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseCheckNotificationDetails¶
Flag denoting whether a DLP Notification Value was configured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPNotificationValueConfigured¶
Flag denoting whether a CTDIvol Notification Value was configured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIvolNotificationValueConfigured¶
Dose Length Product value configured to trigger a notification for a given protocol element From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPNotificationValue¶
CTDIvol value configured to trigger a notification for a given protocol element From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIvolNotificationValue¶
A forward estimate of the DLP for the next Protocol Element Group; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DLPForwardEstimate¶
A forward estimate of the CTDIvol for the next Protocol Element Group; see NEMA XR 25-2010 Dose Check Standard From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CTDIvolForwardEstimate¶
The amount of ionizing radiation to which the patient was exposed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationExposure¶
Type, amount and route of radioactive substance administered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadioactiveSubstanceAdministered¶
Exposure to ionizing radiation and associated preventive measures used to reduce the exposure of parts of the body like lead apron or eye, thyroid gland or gonad protection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationExposureAndProtectionInformation¶
The Size-Specific Dose Estimate is a patient dose estimate that takes into account the size of the patient, such as described in AAPM Report 204 by using linear dimensions measured on the patient or patient images or estimated from patient age From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SizeSpecificDoseEstimation¶
The side-to-side (left to right) dimension of the body part being scanned (per AAPM Report 204) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasuredLateralDimension¶
The thickness of the body part being scanned, in the antero-posterior dimension (per AAPM Report 204) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasuredAPDimension¶
The diameter of the patient at a given location along the Z-axis of the patient, assuming that the patient has a circular cross-section (per AAPM Report 204) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedEffectiveDiameter¶
The Size Specific Dose Estimation is computed using Table 1B (32cm phantom) or Table 2B (16cm phantom) of AAPM Report 204 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AAPM204LateralDimension¶
The Size Specific Dose Estimation is computed using Table 1C (32cm phantom) or Table 2C (16cm phantom) of AAPM Report 204 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AAPM204APDimension¶
The Size Specific Dose Estimation is computed using Table 1A (32cm phantom) or Table 2A (16cm phantom) of AAPM Report 204 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AAPM204SumOfLateralAndAPDimension¶
The Size Specific Dose Estimation is computed using Table 1D (32cm phantom) or Table 2D (16cm phantom) using an effective diameter estimated from the patient’s age using Table 3 of AAPM Report 204 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AAPM204EffectiveDiameterEstimatedFromPatientAge¶
Values calculated from other existing parameters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystemCalculated¶
A segmented region of the detector surface within the irradiated area (but might not be near the center of the detector) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InDetectorPlane¶
A device that creates digital images from X-Ray detectors (Direct, Indirect or Storage) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayReadingDevice¶
Parameters related to the X-Ray source (generator, tube, etc.) are available to the recording application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RaySourceDataAvailable¶
Parameters related to the X-Ray Mechanical System (Stand, Table) are available to the recording application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayMechanicalDataAvailable¶
Parameters related to the X-Ray Detector are available to the recording application From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_RayDetectorDataAvailable¶
Describes the radiographic method of patient, tube and detector positioning to achieve a well described projection or view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProjectionEponymousName¶
Type of Detector used to acquire data; e.g. Images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DetectorType¶
Detector that directly transforms the input signal to pixel values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DirectDetector¶
Detector that transforms an intermediate signal into pixel values; e.g. a scintillator-based detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndirectDetector¶
Storage detector that stores a signal that is later transformed by a reader into pixel values; e.g. a phosphor-based detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StorageDetector¶
Film that is scanned to create pixel values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Film¶
The cassette/detector is mounted in the patient table From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableMount¶
The cassette/detector is not mounted.; e.g. a cassette placed underneath the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnmountedDetector¶
The cassette/detector is mounted in an upright stand From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UprightStandMount¶
The cassette/detector is mounted on a c-arm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- C_ArmMount¶
Method of mounting or positioning a CR/DR cassette or detector From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CR_DRMechanicalConfiguration¶
An integrated projection radiography system capable of fluoroscopy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fluoroscopy_GuidedProjectionRadiographySystem¶
A projection radiography system where the X-Ray detector, X-Ray Source and gantry components are integrated and the managing system is able to access details of each component From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntegratedProjectionRadiographySystem¶
A projection radiography system where the X-Ray detector, X-Ray Source and gantry components are not integrated; e.g. cassette-based CR and DR systems From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cassette_basedProjectionRadiographySystem¶
Description of the algorithm used when reconstructing the image from the data acquired during the acquisition process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReconstructionAlgorithm¶
An algorithm for reconstructing an image from multiple projections by back- projecting the measured values along the line of the projection and filtering the result to reduce blurring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FilteredBackProjection¶
An algorithm for reconstructing an image from multiple projections by starting with an assumed reconstructed image, computing projections from the image, comparing the original projection data and updating the reconstructed image based upon the difference between the calculated and the actual projections From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IterativeReconstruction¶
The period of time from the start of a Procedure Step until the time point established by the context of the reference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureStepToThisPoint¶
Measurement not available: Not a number (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotANumber¶
Measurement not available: Negative Infinity (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NegativeInfinity¶
Measurement not available: Positive Infinity (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositiveInfinity¶
Measurement not available: Divide by zero (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DivideByZero¶
Measurement not available: Underflow (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Underflow¶
Measurement not available: Overflow (per IEEE 754) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Overflow¶
Measurement not available: Measurement failure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementFailure¶
Measurement not available: Measurement not attempted From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementNotAttempted¶
Measurement not available: Calculation failure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalculationFailure¶
Measurement not available: Value out of range From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValueOutOfRange¶
Measurement not available: Value unknown From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValueUnknown¶
Measurement not available: Value indeterminate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValueIndeterminate¶
Measures the time-of-flight of a light signal between the camera and the subject for each point of the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeOfFlight¶
Interferometry is a family of techniques in which waves are superimposed in order to extract depth information about the scanned object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Interferometry¶
Laser scanning describes the general method to sample or scan a surface using laser technology From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LaserScanning¶
Projecting a narrow band of light onto a three-dimensionally shaped surface produces a line of illumination that appears distorted from other perspectives than that of the projector. It can be used for an exact geometric reconstruction of the surface shape From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatternProjection¶
A technique for estimating the surface normal of an object by observing that object under different lighting conditions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ShapeFromShading¶
A technique for estimating the surface normal of an object by observing that object under different motions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ShapeFromMotion¶
An optical imaging technique used to increase optical resolution and contrast of a micrograph by using point illumination and a spatial pinhole to eliminate out-of-focus light in specimens that are thicker than the focal plane. It enables the reconstruction of 3D structures from the obtained images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConfocalImaging¶
Point cloud that was calculated by an algorithm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PointCloudAlgorithmic¶
Scanning the object from different views by placing it on a rotating table From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TurntableScanMethod¶
Higher resolution with a longer acquisition time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HighResolution¶
Lower resolution with a shorter acquisition time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FastMode¶
An algorithm employed to minimize the difference between two clouds of points. It iteratively revises the transformation (translation, rotation) needed to minimize the distance between the points of two point clouds From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IterativeClosestPoint¶
Human controlled minimization of the distance between the points of two point clouds From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Freehand¶
Scanning the object from different views by placing it in front of a checkerboard pattern From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Checkerboard¶
Type of source for observations quoted from an external source From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuotationMode¶
Reference to external source of quoted observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuotedSource¶
Documentary source of quoted observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Document¶
Verbal source of quoted observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Verbal¶
Type of observer that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObserverType¶
Human observer created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Person¶
Automated device created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Device¶
Name of human observer that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonObserverName¶
Organization or institution with which the human observer is affiliated for the context of the current observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonObserver_sOrganizationName¶
Organizational role of human observer for the context of the current observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonObserver_sRoleInTheOrganization¶
Procedural role of human observer for the context of the current observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonObserver_sRoleInThisProcedure¶
Unique identifier of automated device that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverUID¶
Institution-provided identifier of automated device that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverName¶
Manufacturer of automated device that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverManufacturer¶
Manufacturer-provided model name of automated device that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverModelName¶
Manufacturer-provided serial number of automated device that created the observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverSerialNumber¶
Location of automated device that created the observations whilst the observations were being made From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceObserverPhysicalLocationDuringObservation¶
Unique identifier for the Study or Requested Procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureStudyInstanceUID¶
Unique identifier for the Performed Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureStudyComponentUID¶
Identifier for the Order (or Service Request) assigned by the order placer system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlacerNumber¶
Identifier for the Order (or Service Request) assigned by the order filler system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FillerNumber¶
Identifier for the Order (or Service Request) assigned by the department information system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AccessionNumber¶
Type of procedure scheduled or performed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureCode¶
Type of observation subject From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectClass¶
A patient is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Patient¶
Fetus of patient is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fetus¶
Specimen is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Specimen¶
Unique Identifier of patient or fetus who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectUID¶
Name of patient who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectName¶
Identifier of patient or fetus who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectID¶
Birth Date of patient who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectBirthDate¶
Sex of patient who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectSex¶
Age of patient who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectAge¶
Species of patient who is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectSpecies¶
The breed of the subject From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectBreed¶
Name of mother of fetus that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MotherOfFetus¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetusNumber¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfFetuses¶
Unique Identifier of specimen that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenUID¶
Accession Number of specimen that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenAccessionNumber¶
Identifier of specimen that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenIdentifier¶
Coded category of specimen that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpecimenType¶
Identifier of specimen microscope slide that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SlideIdentifier¶
Unique Identifier of specimen microscope slide that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SlideUID¶
The language of the content, being a language that is primarily used for human communication; e.g. English, French From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Language¶
The country-specific variant of language; e.g. Canada for Candadian French From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CountryOfLanguage¶
The language of the value component of a name-value pair From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LanguageOfValue¶
The language of both the name component and the value component of a name- value pair From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LanguageOfNameAndValue¶
The language of the current content item (node in a tree of content) and all its descendants From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LanguageOfContentItemAndDescendants¶
The human readable meaning of the name component of a name-value pair that is equivalent to the post-coordinated meaning conveyed by the coded name and its concept modifier children From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquivalentMeaningOfConceptName¶
The human readable meaning of the value component of a name-value pair that is equivalent to the post-coordinated meaning conveyed by the coded value and its concept modifier children From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquivalentMeaningOfValue¶
Whether or not the property concept being modified is present or absent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PresenceOfProperty¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Present¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Absent¶
A set of points on an image, that when connected by line segments, provide a polyline from which a linear measurement was inferred From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Path¶
A set of points on an image, that when connected by line segments, provide a closed polyline that is the border of a defined region from which an area, or two-dimensional measurement, was inferred From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOutline¶
A set of points on an image, that when connected by line segments, provide a closed polyline that is a two-dimensional border of a three-dimensional region’s intersection with, or projection into the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerimeterOutline¶
The imaging procedure whose results are reported From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureReported¶
Presence or absence of a property is undetermined From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PresenceUndetermined¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- History¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Request¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurrentProcedureDescriptions¶
A description of the imaging procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureDescription¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PriorProcedureDescriptions¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousFindings¶
An observation found on a prior imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreviousFinding¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Findings¶
An observation found on an imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Finding¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Impressions¶
An interpretation in the clinical context of the finding(s) on an imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Impression¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Recommendations¶
A recommendation for management or investigation based on the findings and impressions of an imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Recommendation¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Conclusions¶
An interpretation in the clinical context of the finding(s) on an imaging study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Conclusion¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Addendum¶
Initial images used to esyablish a beginning condition that is used for comparison over time to look for changes. [Paraphrases NCI-PT (C1442488, UMLS, “Baseline”), which is defined as “An initial measurement that is taken at an early time point to represent a beginning condition, and is used for comparison over time to look for changes. For example, the size of a tumor will be measured before treatment (baseline) and then afterwards to see if the treatment had an effect. A starting point to which things may be compared.”] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Baseline¶
A selection of composite instances that best illustrates a particular finding; e.g. an image slice at the location of the largest extent of a tumor From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BestIllustrationOfFinding¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Physician¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Nurse¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Technologist¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Radiographer¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Intern¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Resident¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Registrar¶
A medical practitioner undergoing sub-specialty training; e.g. during the period after specialty training (residency) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fellow¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Attending_Consultant_¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ScrubNurse¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Surgeon¶
A medical practitioner with sub-specialty training in Ultrasound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Sonologist¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Sonographer¶
The person responsible for performing the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Performing¶
The person responsible for referring the patient for the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Referring¶
The person responsible for requesting the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Requesting¶
The person responsible for recording the procedure or observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Recording¶
The person responsible for verifying the recorded procedure or observation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Verifying¶
The person responsible for assisting with the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Assisting¶
The person responsible for making preparations for and monitoring the procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Circulating¶
The person responsible for standing by to assist with the precedure if required From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Standby¶
Other sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherSex¶
Sex of subject undetermined at time of encoding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UndeterminedSex¶
Ambiguous sex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AmbiguousSex¶
Radiation Physicist From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationPhysicist¶
Comment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Comment¶
Indications for Procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndicationsForProcedure¶
Patient condition at the beginning of a healthcare encounter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientPresentation¶
Summary of a procedure, including most significant findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Summary¶
Image or waveform used as source for measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceOfMeasurement¶
Complications from a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Complications¶
Physician who performed a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformingPhysician¶
Summary of patient condition upon Discharge from a healthcare facility From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DischargeSummary¶
Proximal Anatomic Location for a differential measurement; may be considered subtype of term (G-C0E3, SRT, “Finding Site”); e.g. distance or pressure gradient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProximalFindingSite¶
Distal Anatomic Location for a differential measurement; may be considered subtype of term (G-C0E3, SRT, “Finding Site”); e.g. distance or pressure gradient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistalFindingSite¶
Patient Characteristics (findings) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientCharacteristics¶
Time-stamped record of events that occur during a catheterization procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CathLabProcedureLog¶
Room identification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RoomIdentification¶
Equipment identification From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentIdentification¶
A recorded Patient Status or an event involving a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientStatusOrEvent¶
Identification of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureActionItemID¶
DateTime of Recording of an Entry in an Event Log From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeOfRecordingOfLogEntry¶
SOP Instance UID of a Performed Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformedProcedureStepSOPInstanceUID¶
SOP Class UID of a Performed Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerformedProcedureStepSOPClassUID¶
Duration of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureActionDuration¶
Beginning of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartProcedureActionItem¶
End of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndProcedureActionItem¶
Suspension of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SuspendProcedureActionItem¶
Resumption of a step, action, or phase of a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResumeProcedureActionItem¶
Concept modifier for the DateTime of Recording of an Entry in an Event Log From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObservationDateTimeQualifier¶
Recorded DateTime had its source in a system clock not synchronized to other recorded DateTimes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeUnsynchronized¶
Recorded DateTime is estimated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeEstimated¶
Event of the acquisition of an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageAcquired¶
Type of data acquisition device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Modality¶
Number of Frames in a multi-frame image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfFrames¶
Descriptor of an Image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageType¶
Duration of the acquisition of an image or a waveform From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDuration¶
Event of the acquisition of an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WaveformAcquired¶
Document Title From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DocumentTitle¶
Description of Material used in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DescriptionOfMaterial¶
Quantity of Material used in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuantityOfMaterial¶
Billing Code for materials used in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BillingCode¶
Unit or Device Serial Identifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UnitSerialIdentifier¶
Lot Identifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LotIdentifier¶
Vendor or local coded value identifying a device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceCode¶
Identification of a Lesion observed during an imaging procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionIdentifier¶
Person administering drug/contrast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonAdministeringDrug_contrast¶
Assessment of the risk a coronary lesion presents to the health of a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionRisk¶
Identifier for an attempted Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionAttemptIdentifier¶
Use of a device to deploy another device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Deployment¶
Action of a clinical professional at the site of percutaneous access to a patient’s cardiovascular system From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercutaneousEntryAction¶
The action or event of beginning circulatory support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeginCirculatorySupport¶
The action or event of ending circulatory support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndCirculatorySupport¶
Rate of Oxygen Administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OxygenAdministrationRate¶
The action or event of beginning administration of oxygen to a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeginOxygenAdministration¶
The action or event of ending administration of oxygen to a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndOxygenAdministration¶
Method of administration of oxygen to a patient by ventilator From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ByVentilator¶
The action or event of assessing the clinical status of a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAssessmentPerformed¶
The action or event of beginning pacing support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeginPacing¶
The action or event of ending pacing support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndPacing¶
The action or event of beginning ventilation support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeginVentilation¶
The action or event of ending ventilation support for a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndVentilation¶
Procedural note originated by a technologist From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TechNote¶
Procedural note originated by a nurse From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NursingNote¶
Procedural note originated by a Physician From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhysicianNote¶
General procedural note From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureNote¶
List of references to images considered significant From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- KeyImages¶
List of references to DICOM SOP Instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DICOMObjectCatalog¶
Individual frames selected as a subset of a multi-frame image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencedFrames¶
Segment selected as a subset of a segmentation image, specifically the pixels/voxels identified as belonging to the classification of the identified segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencedSegment¶
A device is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubject¶
Name or other identifier of a device that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectName¶
Manufacturer of a device that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectManufacturer¶
Model Name of a device that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectModelName¶
Serial Number of a device that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectSerialNumber¶
Physical Location of a device that is the subject of observations during those observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectPhysicalLocationDuringObservation¶
Unique Identifier of a device that is the subject of observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceSubjectUID¶
Illustration of a region of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IllustrationOfROI¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOutline¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOfDefinedRegion¶
A one dimensional, or linear, numeric measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Distance¶
Vertical measurement value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Height¶
Distance between marks on a device of calibrated size; e.g. a ruler From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Inter_MarkerDistance¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Path¶
A one dimensional, or linear, numeric measurement along a polyline From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PathLength¶
From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerimeterOutline¶
Frame selected from a segmentation image, specifically the pixels/voxels identified as belonging to the classification of the segment encompassing the identified frame From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencedSegmentationFrame¶
A three-dimensional numeric measurement that is approximate, based on a two- dimensional region in a single image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeEstimatedFromSingle2DRegion¶
A three-dimensional numeric measurement that is approximate, based on three or more non-coplanar two-dimensional image regions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeEstimatedFromThreeOrMoreNon_coplanar2DRegions¶
A three-dimensional numeric measurement that is approximate, based on two non- coplanar two-dimensional image regions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeEstimatedFromTwoNon_coplanar2DRegions¶
A three-dimensional numeric measurement of the bounding region of a three- dimensional region of interest in an image set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfBoundingThreeDimensionalRegion¶
A three-dimensional numeric measurement of the bounding sphere of a three- dimensional region of interest in an image set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfCircumscribedSphere¶
A three-dimensional numeric measurement of an ellipsoid shaped three- dimensional region of interest in an image set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfEllipsoid¶
A three-dimensional numeric measurement of a sphere shaped three-dimensional region of interest in an image set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeOfSphere¶
Coordinates of a point on a defined path From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PathVertex¶
Surface of an identified or measured volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeSurface¶
Series of image instances used as source data for a segmentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceSeriesForSegmentation¶
Image instances used as source data for a segmentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceImageForSegmentation¶
Indicates the location of the area of interest as measured from the nipple of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceFromNipple¶
Indicates the location of the area of interest as measured from the most direct skin point of the breast From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceFromSkin¶
Indicates the location of the area of interest as measured from the chest wall From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistanceFromChestWall¶
Patient exposure to ionizing radiation (procedure) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientExposureToIonizingRadiation¶
The act of communicating actionable findings to a responsible receiver From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ResultsCommunicated¶
Reference is to a Doppler waveform acquired simultaneously with an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousDoppler¶
Reference is to a Hemodynamic waveform acquired simultaneously with an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousHemodynamic¶
Reference is to a ECG waveform acquired simultaneously with an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousECG¶
Reference is to a voice narrative recording acquired simultaneously with an image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousVoiceNarrative¶
A waveform representing chest expansion and contraction due to respiratory activity, measured simultaneously with the acquisition of this Image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousRespiratoryWaveform¶
Arterial pulse waveform obtained simultaneously with acquisition of a referencing image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousArterialPulseWaveform¶
Phonocardiographic waveform obtained simultaneously with acquisition of a referencing image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneousPhonocardiographicWaveform¶
Image providing an anatomical reference on the patient under examination, for the purpose of defining the location of the ensuing imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Localizer¶
Image providing an anatomical reference on the patient under examination, for the purpose of planning or documenting a biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiopsyLocalizer¶
Image providing a partial view of the target anatomy, when the target anatomy is too large for a single image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherPartialViews¶
Image providing a view of the target anatomy in a different imaging plane, typically from a near perpendicular angle From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherImageOfBiplanePair¶
Image providing a view of the target anatomy in a different imaging plane, typically with a small angular difference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OtherImageOfStereoscopicPair¶
Image related to a non-image information object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagesRelatedToStandaloneObject¶
Image where signals are identified and separated according to their frequencies; e.g. to identify individual chemicals, or individual nuclei in a chemical compound From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Spectroscopy¶
MR spectroscopy data acquired to correct the phase of the diagnostic data for the phase signal of the Water From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpectroscopyDataForWaterPhaseCorrection¶
An image that has not already been lossy compressed that is used as the source for creation of a lossy compressed image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UncompressedPredecessor¶
Image used as the mask for an image processing operation, such as subtraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaskImageForImageProcessingOperation¶
Image used as the source for an image processing operation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceImageForImageProcessingOperation¶
Series used as the source for an image processing operation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceSeriesForImageProcessingOperation¶
Image used as the source for a derived or compressed image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceImage¶
Image encoded with a lossy compression transfer syntax From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LossyCompressedImage¶
SOP Instance encoded with a different SOP Class but otherwise equivalent data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlternateSOPClassInstance¶
Full fidelity image, uncompressed or lossless compressed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FullFidelityImage¶
Image encoded with a different photometric interpretation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlternatePhotometricInterpretationImage¶
Image used as a source for a montage (stitched) image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceImageForMontage¶
An image that has previously been lossy compressed that is used as the source for creation of another lossy compressed image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LossyCompressedPredecessor¶
HL7 Document Architecture (CDA) Document that contains clinical content equivalent to the referencing Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquivalentCDADocument¶
Instance that contains a displayable complete rendering of the referencing Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompleteRenderingForPresentation¶
Instance that contains a displayable partial rendering of the referencing Instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PartialRenderingForPresentation¶
Instance that contains a displayable complete rendering of the referencing Instance, plus additional content such as inline rendering of referenced images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExtendedRenderingForPresentation¶
Document whose content has been wholly or partially transformed to create the referencing document From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceDocument¶
Image showing structural anatomic features From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnatomicImage¶
Image showing physical or chemical activity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FunctionalImage¶
Image providing the same view of the target anatomy acquired using only a specific imaging wavelength, frequency or energy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SpectralFilteredImage¶
Image providing an anatomical reference on the patient under examination, for the purpose of documenting the location of device such as a diagnostic or therapeutic catheter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceLocalizer¶
Image providing a graphic view of the distribution of radiation dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseImage¶
The referenced image is the source of spatially-related frames from which the referencing 3D volume data set was derived From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionFramesCorrespondingToVolume¶
3D Volume containing the spatially-related frames in the referencing instance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
Instance acquired prior to the referencing instance in a set of consecutively acquired instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TemporalPredecessor¶
Instance acquired subsequent to the referencing instance in a set of consecutively acquired instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TemporalSuccessor¶
Image of the same target area at lower resolution acquired in the same acquisition process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameAcquisitionAtLowerResolution¶
Image of the same target area at higher resolution acquired in the same acquisition process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameAcquisitionAtHigherResolution¶
Image of the same target area at different focal depth (Z-plane) acquired in the same acquisition process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameAcquisitionAtDifferentFocalDepth¶
Image of the same target area at different spectral band acquired in the same acquisition process From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameAcquisitionAtDifferentSpectralBand¶
Image specifically targeting the container label From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagedContainerLabel¶
Source image from which FOR PRESENTATION images were created From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForProcessingPredecessor¶
The reference is to a predecessor report that has been replaced by the current report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReplacedReport¶
The reference is to a predecessor report to which the current report provides and addendum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AddendedReport¶
A report that precedes the final report and may contain only limited information; it may be time sensitive, and it is not expected to contain all the reportable findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PreliminaryReport¶
A report that is not complete From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PartialReport¶
The dose object created was calculated by summation of existing, previously calculated, RT Dose instances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComposedFromPriorDoses¶
The dose object created was calculated by summation of existing, previously calculated, RT Dose instances and dose newly calculated by the application. The newly calculated dose may or may not exist as an independent object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComposedFromPriorDosesAndCurrentPlan¶
RT Dose Instances used as source for calculated dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SourceDoseForComposingCurrentDose¶
Concentration of the chemically or physically interesting (active) ingredient of a drug or contrast agent as delivered in product form from the manufacturer, typically in mg/ml From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ActiveIngredientUndilutedConcentration¶
X-Ray absorption of the active ingredient of a contrast agent ingredient is greater than the absorption of water (tissue) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Contrast_BolusIngredientOpaque¶
Number of units of substance administered to a patient; e.g. tablets From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuantityAdministered¶
Mass of substance administered to a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MassAdministered¶
Method of deriving or calculating a measured value; e.g. mean, or maximum of set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Derivation¶
Assessment of a measurement relative to a normal range of values; may be considered subtype of term (G-C0F2, SRT, “has interpretation”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Normality¶
Significance of a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LevelOfSignificance¶
Status of selection of a measurement for further processing or use From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SelectionStatus¶
Description of a population of measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PopulationDescription¶
Bibliographic or clinical reference for a Description of a population of measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferenceAuthority¶
Description of a normal range of values for a measurement concept From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalRangeDescription¶
Bibliographic or clinical reference for a Description of a normal range of values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalRangeAuthority¶
Observation value selected by user for further processing or use, or as most representative From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UserChosenValue¶
Observation value is the recently obtained, and has been selected for further processing or use From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MostRecentValueChosen¶
Observation value is the mean of several measurements, and has been selected for further processing or use From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanValueChosen¶
Standard deviation of a measurement in a reference population From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardDeviationOfPopulation¶
Percentile Ranking of an observation value with respect a reference population From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercentileRankingOfMeasurement¶
Z-score of an observation value with respect a reference population, expressed as the dimensionless quantity (x-m) /s, where (x-m) is the deviation of the observation value (x) from the population mean (m), and s is the standard deviation of the population From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Z_ScoreOfMeasurement¶
2 Sigma deviation of a measurement in a reference population From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Equation¶
Bibliographic reference to a formula used to compute a derived measurement; reference may be to a specific equation in a journal article From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquationCitation¶
Bibliographic reference to a Table of Values used to look up a derived measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableOfValuesCitation¶
Bibliographic reference to a method used to compute a derived measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MethodCitation¶
A Table of Values used to look up a derived measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TableOfValues¶
Factor (divisor or multiplicand) for normalizing a measurement; e.g. body surface area used for normalizing hemodynamic measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Index¶
Measurement obtained by observer estimation, rather than with a measurement tool or by calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Estimated¶
Measurement obtained by calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Calculated¶
Identified issue about a state or process that has the potential to require intervention or management From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Concern¶
DateTime concern noted (noted by whom is determined by context of use) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeConcernNoted¶
DateTime the concern was resolved From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeConcernResolved¶
DateTime the problem was resolved From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeProblemResolved¶
Place at which healthcare services may be provided From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ServiceDeliveryLocation¶
Identification of a healthcare provider who performed a healthcare service; may be either a person or an organization From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ServicePerformer¶
Type or identifier of a medical device used on, in, or by a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MedicalDeviceUsed¶
Cardiac stress test using pharmacologic and exercise stressors From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PharmacologicAndExerciseStressTest¶
Cardiac stress test using an implanted or external cardiac pacing device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PacedStressTest¶
Procedure for correction of congenital cardiovascular deformity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrectionOfCongenitalCardiovascularDeformity¶
Process of placing patient in the anticipated treatment position, including specification and location of positioning aids, and other treatment delivery accessories From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientSetup¶
Acquisition of patient positioning information prior to treatment delivery, using single-plane megavoltage imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_SinglePlaneMV¶
Acquisition of patient positioning information prior to treatment delivery, using dual-plane megavoltage imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_DualPlaneMV¶
Acquisition of patient positioning information prior to treatment delivery, using single-plane kilovoltage imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_SinglePlaneKV¶
Acquisition of patient positioning information prior to treatment delivery, using dual-plane kilovoltage imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_DualPlaneKV¶
Acquisition of patient positioning information prior to treatment delivery, using dual-plane combination kilovoltage and megavoltage imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_DualPlaneKV_MV¶
Acquisition of patient positioning information prior to treatment delivery, using kilovoltage CT imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_CTKV¶
Acquisition of patient positioning information prior to treatment delivery, using megavoltage CT imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_CTMV¶
Acquisition of patient positioning information prior to treatment delivery, using optical imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_Optical¶
Acquisition of patient positioning information prior to treatment delivery, using ultrasound imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_Ultrasound¶
Acquisition of patient positioning information prior to treatment delivery, using spatial fiducials From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAcquisition_SpatialFiducials¶
Registration of intended and actual patient position prior to treatment delivery, using single-plane images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_SinglePlane¶
Registration of intended and actual patient position prior to treatment delivery, using dual-plane images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_DualPlane¶
Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and an unspecified registration approach From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_3DCTGeneral¶
Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and a marker-based registration approach From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_3DCTMarker_based¶
Registration of intended and actual patient position prior to treatment delivery, using 3D CT images and a volume-based registration approach From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_3DCTVolume_based¶
Registration of intended and actual patient position prior to treatment delivery, using 3D verification images and 2D reference images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_3DOn2DReference¶
Registration of intended and actual patient position prior to treatment delivery, using 2D verification images and 3D reference images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_2DOn3DReference¶
Registration of intended and actual patient position prior to treatment delivery, using optical images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_Optical¶
Registration of intended and actual patient position prior to treatment delivery, using ultrasound images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_Ultrasound¶
Registration of intended and actual patient position prior to treatment delivery, using spatial fiducials From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionRegistration_SpatialFiducials¶
Adjustment of patient position such that the patient is correctly positioned for treatment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionAdjustment¶
Review of patient positioning information in the process of delivering a treatment session From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTPatientPositionIn_treatment_sessionReview¶
Simulated radiotherapy treatment delivery using verification integral to the Treatment Delivery System From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentSimulationWithInternalVerification¶
Simulated radiotherapy treatment delivery using verification by a external Machine Parameter Verifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentSimulationWithExternalVerification¶
Radiotherapy treatment delivery using verification integral to the Treatment Delivery System From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentWithInternalVerification¶
Radiotherapy treatment delivery using verification by an external Machine Parameter Verifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentWithExternalVerification¶
Quality assurance of a radiotherapy treatment delivery using verification integral to the Treatment Delivery System From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAWithInternalVerification¶
Quality assurance of a radiotherapy treatment delivery using verification by an external Machine Parameter Verifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAWithExternalVerification¶
Quality assurance of a Treatment Delivery Device From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTMachineQA¶
Perform Quality Assurance on an RT Plan by evaluating dosimetric content of the current RT Plan From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAByRTPlanDoseCheck¶
Perform Quality Assurance on an RT Plan by comparing the content of previously quality-assessed RT Plans with the current RT Plan From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAByRTPlanDifferenceCheck¶
Perform Quality Assurance on an RT Ion Plan by evaluating dosimetric content of the current RT Ion Plan From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAByRTIonPlanDoseCheck¶
Perform Quality Assurance on an RT Ion Plan by comparing the content of previously quality-assessed RT Ion Plans with the current RT Ion Plan From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RTTreatmentQAWithRTIonPlanDifferenceCheck¶
Indicates whether the treatment to be delivered is a complete fraction or a continuation of previous incompletely treated fraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TreatmentDeliveryType¶
Patient called to procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientCalledToProcedureRoom¶
Patient admitted to procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAdmittedToProcedureRoom¶
Patient given pre-procedure instruction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientGivenPre_procedureInstruction¶
Patient informed consent given From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientInformedConsentGiven¶
Patient advance directive given From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAdvanceDirectiveGiven¶
Nil Per Os (NPO) status confirmed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NilPerOs_NPO_StatusConfirmed¶
Patient assisted to table From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAssistedToTable¶
Patient prepped and draped From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientPreppedAndDraped¶
Patient connected to continuous monitoring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientConnectedToContinuousMonitoring¶
Patient transferred to holding area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTransferredToHoldingArea¶
Patient transferred to surgery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTransferredToSurgery¶
Patient transferred to CCU From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTransferredToCCU¶
Patient disoriented From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDisoriented¶
Patient reports nausea From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientReportsNausea¶
Patient reports discomfort From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientReportsDiscomfort¶
Patient reports chest pain From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientReportsChestPain¶
Patient reports no pain From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientReportsNoPain¶
Patient alert From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAlert¶
Patient restless From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientRestless¶
Patient sedated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientSedated¶
Patient asleep From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientAsleep¶
Patient unresponsive From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientUnresponsive¶
Patient has respiratory difficulty From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientHasRespiratoryDifficulty¶
Patient coughed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientCoughed¶
Patient disconnected from continuous monitoring From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDisconnectedFromContinuousMonitoring¶
Hemostasis achieved From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemostasisAchieved¶
Hemostasis not achieved - oozing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemostasisNotAchieved_Oozing¶
Hemostasis not achieved - actively bleeding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemostasisNotAchieved_ActivelyBleeding¶
Patient given post-procedure instruction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientGivenPost_procedureInstruction¶
Patient discharged from department or laboratory From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientDischargedFromDepartment¶
Patient pronounced dead From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientPronouncedDead¶
Patient transferred to morgue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTransferredToMorgue¶
Identified personnel or staff arrived in procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonnelArrived¶
Identified personnel or staff departed procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PersonnelDeparted¶
Page sent to identified personnel or staff From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PageSentTo¶
Consultation with identified personnel or staff From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConsultationWith¶
Office of identified personnel or staff was called From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OfficeCalled¶
Equipment failure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentFailure¶
Equipment brought to procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentBroughtToProcedureRoom¶
Equipment ready for procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentReady¶
Equipment removed from procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquipmentRemoved¶
Device for obtaining biopsy sample From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bioptome¶
Valvular Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ValvularIntervention¶
Aortic Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AorticIntervention¶
Septal Defect Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeptalDefectIntervention¶
Vascular Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularIntervention¶
Myocardial biopsy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MyocardialBiopsy¶
Arterial conduit angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArterialConduitAngiography¶
Single plane Angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SinglePlaneAngiography¶
Bi-plane Angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bi_planeAngiography¶
Percutaneous Coronary Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PercutaneousCoronaryIntervention¶
15-Lead electrocardiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pre_procedureLog¶
Analysis or measurements for current procedure (purpose of reference to evidence document) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurrentProcedureEvidence¶
Prior report for current patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PriorReportForCurrentPatient¶
Identifier of Consumable taken from inventory From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConsumableTakenFromInventory¶
Identifier of Consumable returned to inventory From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConsumableReturnedToInventory¶
Identifier of consumable whose remaining content has been disposed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RemainingConsumableDisposed¶
Identifier of Consumable determined to be unusable From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConsumableUnusable¶
Identifier of Drug whose administration has started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DrugStart¶
Identifier of Drug whose administration has ended From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DrugEnd¶
Identifier of Drug administered as part of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DrugAdministered¶
Identifier of Contrast agent whose administration has started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastStart¶
Identifier of Contrast agent whose administration has ended From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastEnd¶
Identifier of Contrast agent administered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastAdministered¶
Identifier of Infusate whose administration has started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InfusateStart¶
Identifier of Infusate whose administration has ended From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InfusateEnd¶
Action of a device traversing a vascular lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceCrossedLesion¶
Action of a clinical professional performed on a patient for therapeutic purpose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionAction¶
Volume of Drug, Contrast agent, or Infusate administered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeAdministered¶
Undiluted dose of Drug, Contrast agent, or Infusate administered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UndilutedDoseAdministered¶
Concentration of Drug, Contrast agent, or Infusate administered From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Concentration¶
Rate of Drug, Contrast agent, or Infusate administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RateOfAdministration¶
Duration of Drug, Contrast agent, or Infusate administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DurationOfAdministration¶
Volume of Drug, Contrast agent, or Infusate unadministered or discarded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeUnadministeredOrDiscarded¶
Numeric parameter of Curvature of Catheter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CatheterCurve¶
Transmit Frequency From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TransmitFrequency¶
Measured change of patient electrocardiographic ST level relative to baseline measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- STChangeFromBaseline¶
Anatomic term modifier indicating aneurysm on cited vessel is the subject of the finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AneurysmOnCitedVessel¶
Anatomic term modifier indicating proximal section of graft to cited vessel is the subject of the finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GraftToCitedSegment_ProximalSection¶
Anatomic term modifier indicating mid section of graft to cited vessel is the subject of the finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GraftToCitedSegment_MidSection¶
Anatomic term modifier indicating distal section of graft to cited vessel is the subject of the finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GraftToCitedSegment_DistalSection¶
DateTime of Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateTimeOfIntervention¶
Duration of Intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DurationOfIntervention¶
Lesion stenosis measured prior to any interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaselineStenosisMeasurement¶
Lesion stenosis measured after an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Post_InterventionStenosisMeasurement¶
Assessment of perfusion across a coronary lesion measured prior to any interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaselineTIMIFlow¶
Assessment of perfusion across a coronary lesion measured after an interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Post_InterventionTIMIFlow¶
Indication that device is the primary (first and/or most significant) device used for interventional therapy of a particular pathology; e.g. lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PrimaryInterventionDevice¶
Normal Myocardium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalMyocardium¶
Sacrred Myocardial From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SacrredMyocardial¶
Thinning Myocardium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThinningMyocardium¶
Hemodynamics Report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemodynamicsReport¶
Atrial pressure measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AtrialPressureMeasurements¶
Ventricular pressure measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VentricularPressureMeasurements¶
Gradient assessment, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GradientAssessment¶
Blood velocity measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVelocityMeasurements¶
Blood lab measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodLabMeasurements¶
Derived Hemodynamic Measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedHemodynamicMeasurements¶
Clinical Context, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClinicalContext¶
Location from which the patient was transferred From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PatientTransferredFrom¶
Indication that the procedure includes a percutaneous coronary intervention From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PCIDuringThisProcedure¶
Radiation dose times area of exposure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoseAreaProduct¶
Finding of probability and/or severity of thrombus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DegreeOfThrombus¶
Severity of Calcification, property of lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SeverityOfCalcification¶
Lesion Morphology; form and/or structural properties of lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionMorphology¶
Vessel Morphology; form and/or structural properties of vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VesselMorphology¶
Technique (device or procedure) of support for patient circulatory system; hemodynamic support From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CirculatorySupport¶
Reason for Exam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReasonForExam¶
Indication that the current exam data has been compared with prior exam data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComparisonWithPriorExamDone¶
Electrocardiographic electrode placement technique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ElectrodePlacement¶
Acquisition Device Type From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDeviceType¶
Acquisition Device ID From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDeviceID¶
Quantitative Analysis, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuantitativeAnalysis¶
Qualitative Analysis, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QualitativeAnalysis¶
The date and time on which a procedure was performed on a patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureDateTime¶
Clinical Interpretation, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClinicalInterpretation¶
ECG Lead Identifier From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeadID¶
Beat Number; ordinal of cardiac cycle within an acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BeatNumber¶
Complex coded semantic unit, consisting of several coded components From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CompoundStatement¶
Trend (temporal progression) of a clinical condition, finding, or disease From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Trend¶
Coded semantic unit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Statement¶
Coded modifier for a semantic unit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StatementModifier¶
Conjunctive term between semantic units From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ConjunctiveTerm¶
Probability From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Probability¶
ECG Global Measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ECGGlobalMeasurements¶
ECG Lead Measurements, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ECGLeadMeasurements¶
Derived cross-sectional area of a vessel or anatomic feature, other than a cardiac valve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedArea_Non_Valve¶
Rate of blood flow through Pulmonary artery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulmonaryFlow¶
Rate of blood flow through the aorta From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystemicFlow¶
DateTime of patient discharge from hospital admission From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DischargeDateTime¶
Indication that a Coronary Artery Bypass operation was performed during the current hospital admission From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CoronaryArteryBypassDuringThisAdmission¶
Date of Death From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DateOfDeath¶
Indication that the patient died during the current hospital admission From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeathDuringThisAdmission¶
Indication that the patient died during the current Catheterization procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeathDuringCatheterization¶
Finding of type of Myocardial Infarction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TypeOfMyocardialInfarction¶
Finding of Coronary lesion with greater than 50% stenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CoronaryLesion_50_Stenosis¶
Finding of Acute Myocardial Infarction Presence as indication for interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcuteMIPresent¶
DateTime of first determination of elevated ECG ST segment, as indication of Myocardial Infarction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- STElevationOnsetDateTime¶
Number of lesion interventions attempted during current procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfLesionInterventionsAttempted¶
Number of lesion interventions successful during current procedure, where the residual post intervention stenosis is less than or equal to 50% of the arterial luminal diameter, TIMI Flow is 3 and the minimal decrease in stenosis was 20% From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfLesionInterventionsSuccessful¶
Overall success of interventional procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureResult¶
Lesion Intervention Information, report section From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionInterventionInformation¶
Indication that Myocardial Infarction occurred during current procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Peri_proceduralMIOccurred¶
Creatine Kinase-MB value at baseline (start of procedure) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CK_MBBaseline¶
Creatine Kinase-MB highest value measured during procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CK_MBPeak¶
Time interval between ECG R-wave peaks in subsequent cardiac cycles From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R_RInterval¶
Blood temperature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodTemperature¶
Blood Oxygen content From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodOxygenContent¶
Blood Carbon dioxide saturation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodCarbonDioxideSaturation¶
Pulmonary Arterial Content (FCpa) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulmonaryArterialContent_FCpa_¶
Pulmonary Venous Content (FCpv) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulmonaryVenousContent_FCpv_¶
Max dp/dt/P From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaxDp_dt_P¶
Ventricular End Diastolic pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VentricularEndDiastolicPressure¶
Elapsed time from injection of an indicator bolus until it is observed at another location From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndicatorAppearanceTime¶
Maximum pressure acceleration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumPressureAcceleration¶
Ventricular Systolic blood pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VentricularSystolicBloodPressure¶
Pulse Strength; palpable strength of systolic flow From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PulseStrength¶
The secondary peak pressure in the atrium during atrial contraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CWavePressure¶
Gradient pressure, average From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GradientPressure_Average¶
Gradient pressure, peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GradientPressure_Peak¶
Pressure at dp/dt max From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PressureAtDp_dtMax¶
Diastolic blood velocity, mean From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiastolicBloodVelocity_Mean¶
Diastolic blood velocity, peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiastolicBloodVelocity_Peak¶
Systolic blood velocity, mean From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystolicBloodVelocity_Mean¶
Systolic blood velocity, peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SystolicBloodVelocity_Peak¶
Blood velocity, mean From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVelocity_Mean¶
Blood velocity, minimum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVelocity_Minimum¶
Blood velocity, peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVelocity_Peak¶
Venous or atrial pressure minimum during ventricular systole, after A-wave From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_descentPressure¶
Venous or atrial pressure minimum when tricuspid valve opens during diastole, after V-wave From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Y_descentPressure¶
Atrial pressure upon closure of tricuspid and mitral valves From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Z_pointPressure¶
Left Ventricular ejection time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricularEjectionTime¶
Left Ventricular filling time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricularFillingTime¶
Right Ventricular ejection time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightVentricularEjectionTime¶
Right Ventricular filling time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightVentricularFillingTime¶
Total Pulmonary Resistance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalPulmonaryResistance¶
Total Vascular Resistance From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalVascularResistance¶
Coronary Flow reserve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CoronaryFlowReserve¶
Diastolic/Systolic velocity ratio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Diastolic_SystolicVelocityRatio¶
Hyperemic ratio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HyperemicRatio¶
Hemodynamic Resistance Index From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HemodynamicResistanceIndex¶
Thorax diameter, sagittal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThoraxDiameter_Sagittal¶
Environmental characteristics in the procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureEnvironmentalCharacteristics¶
Oxygen concentration in the procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RoomOxygenConcentration¶
Temperature in the procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RoomTemperature¶
Barometric pressure in the procedure room From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RoomBarometricPressure¶
Left to Right Flow From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftToRightFlow¶
Right to Left Flow From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightToLeftFlow¶
Arteriovenous oxygen content difference From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArteriovenousDifference¶
Framingham Study 10 Year CHD Risk From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComparativeAverage10YearCHDRisk¶
Framingham Study Comparative Low10 Year CHD Risk From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ComparativeLow10YearCHDRisk¶
Framingham Study LDL Cholesterol Score Sheet for Men From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LDLCholesterolScoreSheetForMen¶
Framingham Study LDL Cholesterol Score Sheet for Women From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LDLCholesterolScoreSheetForWomen¶
Framingham Study Total Cholesterol Score Sheet for Men From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalCholesterolScoreSheetForMen¶
Framingham Study Total Cholesterol Score Sheet for Women From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalCholesterolScoreSheetForWomen¶
Corrected Sinus Node Recovery Time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrectedSinusNodeRecoveryTime¶
Max volume normalized to 50mmHg pulse pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaxVolumeNormalizedTo50mmHgPulsePressure¶
Oxygen Consumption From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OxygenConsumption¶
Body Surface Area computed from patient height and weight: BSA = 3.207*WT[g]^(0.7285-0.0188 log (WT[g])) *HT[cm] ^ 0.3 [Boyd E, The growth of the surface area of the human body. Minneapolis: University of Minnesota Press, 1935, eq. (36) ] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_3_207_WT_0_7285_0_0188Log_WT_HT_0_3¶
Body Surface Area computed from patient height and weight: BSA = 0.007184* WT[kg] ^ 0.425*HT[cm] ^ 0.725 [Dubois and Dubois, Arch Int Med 1916 17:863-71] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_007184_WT_0_425_HT_0_725¶
Body Surface Area computed from patient height and weight: BSA = 0.0235* WT[kg] ^0.51456*HT[cm]^ 0.42246 [Gehan EA, George SL, ‘Estimation of human body surface area from height and weight’, Cancer Chemother Rep 1970 54:225-35] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_0235_WT_0_51456_HT_0_42246¶
Body Surface Area computed from patient height and weight: BSA = 0.024265 * WT[kg] ^ 0.5378 * HT[cm] ^ 0.3964 [Haycock G.B., Schwartz G.J., Wisotsky D.H. ‘Geometric method for measuring body surface area: A height weight formula validated in infants, children and adults.’ The Journal of Pediatrics 1978 93:1:62-66] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_024265_WT_0_5378_HT_0_3964¶
Body Surface Area computed from patient height and weight: BSA = (HT[m] * WT[kg] / 36) ^ 0.5 [Mosteller, R.D. ‘Simplified Calculation of Body Surface Area.’ N Engl J Med 1987 Oct 22;317(17):1098] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_HT_WT_36_0_5¶
Body Surface Area computed from patient weight:BSA = 1321 + 0.3433 * WT[kg] (for pediatrics 3-30 kg) [Current, J.D. ‘A Linear Equation For Estimating The Body Surface Area In Infants And Children’, The Internet Journal of Anesthesiology. 1998. 2:2] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_1321_0_3433_WT¶
BSA = 0.0004688 * (1000 * WT) ^ (0.8168 - 0.0154 * log(1000 * WT)) Where (WT is weight in kilogram) Units = m2 Boyd, Edith. The Growth of the Surface Area of the Human Body(originally published in 1935 by the University of Minnesota Press), Greenwood Press, Westport, Connecticut, 1975, p. 102.Equation (35) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_0004688_WT_0_8168_0_0154_Log_WT_¶
Equation for estimated oxygen consumption: VO2male = BSA (138.1 - 11.49 * loge(age) + 0.378 * HRf) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2male_BSA_138_1_11_49_Loge_age_0_378_HRf_¶
Equation for estimated oxygen consumption: VO2female = BSA (138.1 - 17.04 * loge(age) + 0.378 * HRf) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2female_BSA_138_1_17_04_Loge_age_0_378_HRf_¶
Equation for estimated oxygen consumption: VO2 = VeSTPD * 10 * (FIO2 - FE02) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2_VeSTPD_10_FIO2_FE02_¶
Equation for estimated oxygen consumption: VO2 = 152 * BSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2_152_BSA¶
Equation for estimated oxygen consumption: VO2 = 175 * BSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2_175_BSA¶
Equation for estimated oxygen consumption: VO2 = 176 * BSA From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VO2_176_BSA¶
Robertson & Reid Table for estimated oxygen consumption From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Robertson_ReidTable¶
Fleisch table for estimated oxygen consumption From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FleischTable¶
Boothby table for estimated oxygen consumption From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BoothbyTable¶
Estimate of Oxygen partial pressure at 50% saturation for premature infants less than 3 days old: P50 = 19.9 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_premAge_3days_P50_19_9¶
Estimate of Oxygen partial pressure at 50% saturation for infants less than 1 day old: P50 = 21.6 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_age_1day_P50_21_6¶
Estimate of Oxygen partial pressure at 50% saturation for infants less than 30 days old: P50 = 24.6 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_age_30day_P50_24_6¶
Estimate of Oxygen partial pressure at 50% saturation for patients less than 18 years old: P50 = 27.2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_age_18y_P50_27_2¶
Estimate of Oxygen partial pressure at 50% saturation for patients less than 40 years old: P50 = 27.4 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_age_40y_P50_27_4¶
Estimate of Oxygen partial pressure at 50% saturation for patients more than 60 years old: P50 = 29.3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- If_age_60y_P50_29_3¶
Cardiac valve area computed from flow and pressure gradient: Area = Flow / 44.5 * sqrt(Gradient[mmHg]) [Gorlin and Gorlin, Am Heart J, 1951] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Area_Flow_44_5_Sqrt_Gradient_mmHg_¶
Mitral valve area computed from flow and pressure gradient: Mitral valve Area = Flow / 38.0 * sqrt(Gradient[mmHg]) [Gorlin and Gorlin, Am Heart J, 1951] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MVA_Flow_38_0_Sqrt_Gradient_mmHg_¶
Body Mass Index computed from weight and height: BMI = Wt/Ht^2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BMI_Wt_Ht_2¶
Body Surface Area computed from patient height and weight: BSA = 0.007358 * WT[kg] ^ 0.425 * HT[cm] ^ 0.725 (for East Asian adult, aged 15+ years) [Kanai Izumi, Masamitsu Kanai, ‘Clinical examination method summary’] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_007358_WT_0_425_HT_0_725¶
Body Surface Area computed from patient height and weight: BSA = 0.010265 * WT[kg] ^ 0.423 * HT[cm] ^ 0.651 (For East Asian child aged 12-14 years) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_010265_WT_0_423_HT_0_651¶
Body Surface Area computed from patient height and weight: BSA = 0.008883* WT[kg] ^ 0.444 * HT[cm] ^ 0.663 (For East Asian child aged 6-11 years) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_008883_WT_0_444_HT_0_663¶
Body Surface Area computed from patient height and weight: BSA = 0.038189 * WT[kg] ^ 0.423 * HT[cm] ^ 0.362 (For East Asian child aged 1-5 years) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_038189_WT_0_423_HT_0_362¶
Body Surface Area computed from patient height and weight: BSA = 0.009568* WT[kg] ^ 0.473 * HT[cm] ^ 0.655 (For East Asian child aged 0-12 months) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_0_009568_WT_0_473_HT_0_655¶
Skin Condition Warm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionWarm¶
Skin Condition Cool From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionCool¶
Skin Condition Cold From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionCold¶
Skin Condition Dry From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionDry¶
Skin Condition Clammy From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionClammy¶
Skin Condition Diaphoretic From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionDiaphoretic¶
Skin Condition Flush From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionFlush¶
Skin Condition Mottled From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionMottled¶
Skin Condition Pale From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SkinConditionPale¶
Airway unobstructed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirwayUnobstructed¶
Airway partially obstructed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirwayPartiallyObstructed¶
Airway severely obstructed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AirwaySeverelyObstructed¶
Anatomy could not be visualized for the purpose of evaluation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NotVisualized¶
Quantitative Arteriography Report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuantitativeArteriographyReport¶
Quantitative Ventriculography Report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- QuantitativeVentriculographyReport¶
Guidewire crossing lesion unsuccessful From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GuidewireCrossingLesionUnsuccessful¶
Guidewire crossing lesion successful From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GuidewireCrossingLesionSuccessful¶
Angioplasty balloon inflated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AngioplastyBalloonInflated¶
Angioplasty balloon deflated From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AngioplastyBalloonDeflated¶
Device deployed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeviceDeployed¶
Stent re-expanded From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentRe_expanded¶
Object removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ObjectRemoved¶
Radiation applied From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationApplied¶
Radiation removed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiationRemoved¶
Interventional device placement unsuccessful From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionalDevicePlacementUnsuccessful¶
Interventional device placed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionalDevicePlaced¶
Intervention performed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionPerformed¶
Interventional device withdrawn From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterventionalDeviceWithdrawn¶
Catheter Size From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CatheterSize¶
Injectate Temperature From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InjectateTemperature¶
Injectate Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InjectateVolume¶
Factor by which a measured or calculated value is multiplied to obtain the estimated real-world value From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationFactor¶
Intravascular Ultrasound Report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IVUSReport¶
External Elastic Membrane (EEM) diameter measured through the center point of the vessel. Center point of the vessel is defined as the center of gravity of the EEM area. The EEM is a discrete interface at the border between the media and the adventitia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EEMDiameter¶
The distance from intimal leading edge to the external elastic membrane along any line passing through the luminal center, which is defined as the center of gravity of the lumen area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaquePlusMediaThickness¶
Planimetered perimeter of the lumen From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LumenPerimeter¶
Vessel area measured at the External Elastic Membrane (EEM), a discrete interface at the border between the media and the adventitia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EEMCross_SectionalArea¶
Area within the EEM occupied by atheroma, regardless of lumen compromise. Plaque plus Media Area = EEM cross-sectional area - vessel lumen cross- sectional area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaquePlusMediaCross_SectionalArea¶
Measurement of in-stent restenosis. In-Stent Intimal Area = Stent cross- sectional area - vessel lumen cross-sectional area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- In_StentNeointimalCross_SectionalArea¶
Longitudinal extent of the Vascular Volume Measurement. This is the distance from the distal edge to the proximal edge of the Volume measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularVolumeMeasurementLength¶
Longitudinal distance from the closest edge of a fiducial feature or reference location to the start of the vascular measurement. This value will be a positive if the measurement is distal to the fiducial feature or reference location, or negative if the measurement is proximal to the fiducial feature or reference location From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativePosition¶
In-Stent Neointimal Volume / Stent Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentVolumeObstruction¶
Reference, normally anatomical, which is used for locating the position of a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FiducialFeature¶
Longitudinal calcium length measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumLength¶
Measurement of vessel lumen eccentricity. Lumen Eccentricity Index = (maximum vessel lumen diameter - minimum vessel lumen diameter) / maximum vessel lumen diameter. Lumen diameters are measured through the center point of the lumen, which is defined as the center of gravity of the lumen area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LumenEccentricityIndex¶
Plaque plus Media Eccentricity Index = (maximum Plaque plus media thickness - minimum Plaque plus media thickness) / maximum Plaque plus media thickness From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaquePlusMediaEccentricityIndex¶
Measurement of increase or decrease in EEM area that occurs during the development of atherosclerosis. Remodeling Index = Lesion EEM area / reference EEM area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RemodelingIndex¶
Measurement of stent circularity. Stent Symmetry Index = (maximum stent diameter - minimum stent diameter) / maximum stent diameter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentSymmetryIndex¶
Measurement of stent area relative to the reference lumen area. Stent Expansion Index = Minimum stent area / reference vessel lumen cross-sectional area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentExpansionIndex¶
Measurement of vessel lumen eccentricity. Lumen Shape Index = (2p * sqrt(Vessel lumen cross-sectional area / p) / Lumen Perimeter) 2 Reference: Tobis & Yock, “Intravascular Ultrasound Imaging”, Chapter 7 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LumenShapeIndex¶
Lumen diameter ratio = minimum vessel lumen diameter / maximum vessel lumen diameter, measured at the same cross section in the vessel. Lumen diameters are measured through the center point of the lumen, which is defined as the center of gravity of the lumen area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LumenDiameterRatio¶
Stent diameter ratio = Minimum stent diameter / Maximum stent diameter, measured at the same cross section in the vessel. Stent diameters are measured through the center point of the stent, which is defined as the center of gravity of the stent area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentDiameterRatio¶
EEM diameter ratio = minimum EEM diameter / maximum EEM diameter. Measured at the same cross section in the vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EEMDiameterRatio¶
Fractional area within the External Elastic Membrane (EEM) occupied by atheroma. Plaque Burden = (EEM area - vessel lumen cross-sectional area) / EEM area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaqueBurden¶
Angular measurement of a Calcium deposit with the apex located at the center of the lumen, which is defined as the center of gravity of the lumen area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArcOfCalcium¶
Plaque characterized by low density or echogenicity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SoftPlaque¶
Abnormal thickening of the intima within the stented segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- In_StentNeointima¶
Lumen surrounded by all three layers of the vessel-intima, media, and adventitia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TrueLumen¶
A channel, usually parallel to the true lumen, which does not communicate with the true lumen over a portion of its length From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FalseLumen¶
Plaque ulceration with a tear detected in a fibrous cap From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaqueRupture¶
Length of gap between two consecutive stents From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentGap¶
Worst stenosis - the stenosis with the smallest lumen size within a vessel segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T_1Worst¶
2nd most severe stenosis within a vessel segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T_2Secondary¶
3rd most severe stenosis within a vessel segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T_3Secondary¶
4th most severe stenosis within a vessel segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T_4Secondary¶
External Elastic Membrane (EEM) volume measured within a specified region. The EEM is a discrete interface at the border between the media and the Adventitia From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EEMVolume¶
Lumen volume measured within a specified region From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LumenVolume¶
The amount of plaque between the lumen and stent, within the stent region; In- stent restenosis. In-Stent Neointimal Volume = Stent Volume - Lumen Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- In_StentNeointimalVolume¶
The amount of plaque between the stent and the EEM, within the stent region. Native Plaque Volume = EEM Volume - Stent Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NativePlaqueVolume¶
Total amount of plaque between the EEM and the Lumen, over the entire region that is measured. Total Plaque Volume = EEM Volume - Lumen Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalPlaqueVolume¶
Proximal reference segment measurement site. Typically the site with the largest lumen proximal to a stenosis but within the same segment (usually within 10 mm of the stenosis with no major intervening branches) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProximalReference¶
Distal reference segment measurement site. Typically the site with the largest lumen distal to a stenosis but within the same segment (usually within 10 mm of the stenosis with no major intervening branches) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistalReference¶
Site of the smallest lumen in a vessel; e.g. due to a stenotic lesion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SiteOfLumenMinimum¶
Measurement region that encompasses the entire vessel imaged in a single pullback acquisition From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EntirePullback¶
Measurement region occupied by the stent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentedRegion¶
Region starting at the proximal edge of the Stent and extending several millimeters (usually 5 mm) proximal to the Stent edge From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProximalStentMargin¶
Region starting at the distal edge of the Stent and extending several millimeters (usually 5 mm) distal to the Stent edge From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DistalStentMargin¶
Classification of dissections in a vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DissectionClassification¶
Separation of neointimal hyperplasia from stent struts, usually seen only after treatment of in-stent restenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Intra_stentDissection¶
Plaque with a thin cap fibrous atheroma that is at increased risk of rupture and thrombosis (or re-thrombosis) and rapid stenosis progression From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VulnerablePlaque¶
Plaque erosions with no structural defect (beyond endothelial injury) or gap in the plaque From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ErodedPlaque¶
Stenosis severity classifications of multiple lesions in a vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RelativeStenosisSeverity¶
A finding of a previously treated lesion in which stenosis has reoccurred From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RestenoticLesion¶
Loosely packed bundles of collagen fibers with regions of lipid deposition present. Region is cellular and no cholesterol clefts or necrosis are present. Some macrophage infiltration. Increase in extra cellular matrix From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fibro_LipidicPlaque¶
Area within the plaque with very low echogenicity separated from the lumen and surrounded by more echogenic structures (fibrous cap). Highly lipidic necrotic region with remnants of foam cells and dead lymphocytes present. No collagen fibers are visible and mechanical integrity is poor. Cholesterol clefts and micro calcifications are visible From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Necrotic_LipidicPlaque¶
Dissection limited to the intima or atheroma, and not extending to the media From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntimalDissection¶
Dissection in the arterial Media, extending into the media From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MedialDissection¶
The referenced information was acquired simultaneously with the information in the object in which the reference occurs From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimultaneouslyAcquired¶
Information acquired for the same anatomic region From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameAnatomy¶
Information acquired for the same indication; e.g. to elucidate the same diagnostic question From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SameIndication¶
The referenced information was used to correct the data for differential attenuation through different anatomic tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ForAttenuationCorrection¶
Value estimated for a vessel in the absence of a stenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Reconstructed¶
Manufacturer of application used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlgorithmManufacturer¶
Left Atrial Ejection Fraction by Angiography From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftAtrialEjectionFractionByAngiography¶
Left Atrial End Diastolic Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftAtrialEDVolume¶
Left Atrial End Systolic Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftAtrialESVolume¶
Contour repositioning of End Diastolic relative to End Systolic contour From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContourRealignment¶
The minimum standard deviation to define the hypokinesis and hyperkinesis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThresholdValue¶
Report of differentiation of wall motion compared to normal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalAbnormalWallMotion¶
Object used for Calibration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationObject¶
Method used for Calibration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationMethod¶
Size of calibration object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationObjectSize¶
Method how long axis is positioned From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaLengthMethod¶
Model for cardiac chamber volume calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeMethod¶
Method to define original diameter of the artery From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferenceMethod¶
Relation between calculated End Diastolic volume and ventricular End Diastolic volume. The specific meaning is dependent on volume method used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegressionSlopeED¶
Correction factor for the calculated End Diastolic volume and ventricular End Diastolic volume. The specific meaning is dependent on volume method used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegressionOffsetED¶
Relation between calculated End Systolic volume and ventricular End Systolic volume. The specific meaning is dependent on volume method used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegressionSlopeES¶
Correction factor for the calculated End Systolic volume and ventricular End Systolic volume. The specific meaning is dependent on volume method used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegressionOffsetES¶
Exponent of volume in regression formula From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegressionVolumeExponent¶
Container for spatial locations or coordinates used for calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencePoints¶
Average thickness of the chamber wall in the current view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallThickness¶
Volume of the chamber wall estimated from the current view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallVolume¶
Mass of the chamber wall (myocardium) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallMass¶
Peak systolic stress of chamber wall From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallStress¶
Method to calculate wall motion [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CenterlineWallMotionAnalysis¶
The length between End Diastolic and End Systolic contour perpendicular on the centerline normalized by a method dependent ventricular perimeter length. The centerline is the line equidistant between the End Diastolic and End Systolic contour [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalizedChordLength¶
The report of the boundaries of the abnormal (hyperkinetic, hypokinetic, a-kinetic) regions associated with the territory of the artery [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbnormalRegion¶
The chord number specifying the begin of abnormal region [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FirstChordOfAbnormalRegion¶
The chord number specifying the end of abnormal region [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LastChordOfAbnormalRegion¶
Severity at the regional abnormality extent [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TerritoryRegionSeverity¶
Severity at the opposite regional abnormality extent [example: Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OppositeRegionSeverity¶
Based on a total number of chords of 100 and RAO project the range of chords belonging to this circumferential extent lies between 5 - 85. [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LADRegionInRAOProjection¶
Based on a total number of chords of 100 and RAO project the range of chords belonging to this circumferential extent lies between 25 - 85. [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RCARegionInROAProjection¶
Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 10 - 66 (hypokinetic) and 67 - 80 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleLADRegionInRAOProjection¶
Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 51 - 80 (hypokinetic) and 10 - 50 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingleRCARegionInRAOProjection¶
Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 10 - 58 (hypokinetic) and 59 -80 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultipleLADRegionInRAOProjection¶
Based on a total number of chords of 100 and RAO projection the range of chords belonging to this regional extent lies between 59 - 80 (hypokinetic) and 10 - 58 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultipleRCARegionInRAOProjection¶
Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 50 -100 (hypokinetic) and 20 - 49 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LADRegionInLAOProjection¶
Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 19 - 67 (hypokinetic) and 68 - 100 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RCARegionInLAOProjection¶
Based on a total number of chords of 100 and LAO projection the range of chords belonging to this regional extent lies between 38 -74 (hypokinetic) and 75 - 100 (hyperkinetic). [Sheehan, 1986] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CFXRegionInLAOProjection¶
Method based on assumption that the image object is circular From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CircularMethod¶
Method based on the gray value distribution of the image From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DensitometricMethod¶
End Systolic contour realigned to End Diastolic contour based on the center of gravity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CenterOfGravity¶
End Systolic contour realigned to End Diastolic contour based on the mid point of the long axis. The long axis end-points are defined as the posterior and apex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LongAxisBased¶
No Contour Realignment applied From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoRealignment¶
Calculated Vessel Lumen Cross-Sectional Area based on the referenced method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VesselLumenCross_SectionalArea¶
Location of the beginning of a contour From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContourStart¶
Location of the end of a contour From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContourEnd¶
Sphere is used as calibration object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Sphere¶
Object of interest in isocenter of image and pixel separation is calculated from geometric data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GeometricIsocenter¶
Object of interest not in isocenter of image and pixel separation is calculated from geometric data and out of isocenter distances From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GeometricNon_Isocenter¶
Object used for calibration; e.g. sphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalibrationObjectUsed¶
Application dependent method to calculate the reference diameter based on the multiple diameter values From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurveFittedReference¶
Application dependent method to calculate reference by interpolation, based on the diameter of two or more user defined reference positions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InterpolatedLocalReference¶
Application dependent method to calculate by averaging the reference, based on the diameter of one or more user defined reference positions From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeanLocalReference¶
Method to calculate wall motion based on the lengths of the radials in the predefined regions [Ingels] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadialBasedWallMotionAnalysis¶
Contribution of Region to global Ejection factor based on radial or landmark based wall motion method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalContributionToEjectionFraction¶
The reduction of area between End Systolic and End Diastolic based on radial wall motion analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadialShortening¶
Method to calculate wall motion based on the move of landmarks on the wall [Slager] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LandmarkBasedWallMotionAnalysis¶
Contribution to the ejection fraction of a specific slice region [Slager] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SliceContributionToEjectionFraction¶
Method to calculate volumes of heart chambers for every image in a range From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FrameToFrameAnalysis¶
The area is derived by considering a set of coordinates as a closed irregular polygon, accounting for inner angles. The exact method, such as by decomposition into triangles or quadrilaterals, is not specified, since it does not affect the numeric result, apart from the effect of numeric precision during computation of intermediate results From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOfClosedIrregularPolygon¶
The area is derived by using a set of coordinates as control points for a Non Uniform Rational B-Spline (NURBS) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaOfAClosedNURBS¶
The volume derived by integrating the sum of the areas on adjacent slices across the slice interval; each area is defined by a regular planar shape or by considering a set of coordinates as a closed irregular polygon, accounting for inner angles From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntegrationOfSumOfClosedAreasOnContiguousSlices¶
Procedure used to calibrate measurements or measurement devices From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Calibration¶
Left contour of lumen (direction proximal to distal) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftContour¶
Right contour of lumen (direction proximal to distal) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightContour¶
Ordered set of diameters values derived from contours (direction proximal to distal) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiameterGraph¶
Length Luminal Segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LengthLuminalSegment¶
Increment value along X-axis in Diameter Graph From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GraphIncrement¶
Location of the maximum lumen area in a lesion or vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SiteOfMaximumLuminal¶
Ordered set of cross-sectional Vessel Lumen Cross-Sectional Area values derived from contours (direction proximal to distal) based on densitometric method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DensitometricLuminalCross_sectionalAreaGraph¶
Position of proximal border of segment relative to the contour start (proximal end of analysis area) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionOfProximalBorder¶
Position of distal border of segment relative to the contour start (proximal end of analysis area) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PositionOfDistalBorder¶
Longitudinal cross sectional area of plaque From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaqueArea¶
Symmetry of stenosis (0 = complete asymmetry, 1 = complete symmetry); see Section T.2 “Definition of Diameter Symmetry with Arterial Plaques” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiameterSymmetry¶
Symmetry of plaque (0 = complete asymmetry, 1 = complete symmetry); see Section T.2 “Definition of Diameter Symmetry with Arterial Plaques” in PS3.17 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaSymmetry¶
The average slope of the diameter function between the position of the minimum luminal diameter and the position of the proximal border of the segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- InflowAngle¶
The average slope of the diameter function between the position of the minimum luminal diameter and the position of the distal border of the segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OutflowAngle¶
The relation between coronary pressure and coronary flow From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StenoticFlowReserve¶
Poiseuille Resistance at the location of the stenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PoiseuilleResistance¶
Turbulence Resistance at the location of the stenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TurbulenceResistance¶
Pressure drop over the stenosis at maximum heart output From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PressureDropAtSFR¶
Method for selection of vessel sub-segments From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SegmentationMethod¶
Estimate of the volume of blood flow in the absence of stenosis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EstimatedNormalFlow¶
Area Length method defined by Kennedy [Kennedy, 1970] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaLengthKennedy¶
Area Length method defined by Dodge [Dodge, 1960] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaLengthDodge¶
Area Length method defined by Wynne [Wynne] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaLengthWynne¶
Volume method based on multiple slice From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultipleSlices¶
Volume method defined by Boak [Boak] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Boak¶
Volume method defined by Ferlinz [Ferlinz] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TSPyramid¶
Volume method defined by Graham [Graham] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TwoChamber¶
Volume method defined by Arcilla [Arcilla] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Parallelepiped¶
Corrected Body Surface area for indexing the hemodynamic measurements for a pediatric patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BSA_1_219¶
Method for selecting sub-segments that are all of the same length From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EquidistantMethod¶
Manually selected start and end of sub-segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- UserSelectedMethod¶
Left ventricular posterobasal segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricularPosterobasalSegment¶
Report of a Cardiovascular Analysis, typically from a CT or MR study From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CardiovascularAnalysisReport¶
Ventricular Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VentricularAnalysis¶
Myocardial Perfusion Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MyocardialPerfusionAnalysis¶
Calcium Scoring Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumScoringAnalysis¶
Flow Quantification Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlowQuantification¶
Vascular Morphological Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularMorphologicalAnalysis¶
Vascular Functional Analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularFunctionalAnalysis¶
Analysis of myocardial wall thickening From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ThickeningAnalysis¶
Section Heading for absolute values of ventricular measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AbsoluteValuesOfVentricularMeasurements¶
Results of normalizing ventricular measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NormalizedValuesOfVentricularMeasurements¶
Reference Point of a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ReferencePoint¶
Central breathing position between inspiration and expiration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CentralBreathingPosition¶
Peak of the ventricular ejection rate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakEjectionRate¶
Time of the peak of ventricular ejection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakEjectionTime¶
Peak of the fluid filling rate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakFillingRate¶
Time interval until time of peak filling from a given reference point; e.g. end systole From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakFillingTime¶
Papillary muscle was excluded from the measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PapillaryMuscleExcluded¶
Papillary muscle was included in the measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PapillaryMuscleIncluded¶
The ratio of the end-systolic wall thickness compared to the end-diastolic wall thickness From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WallThicknessRatioEnd_systolicToEnd_diastolic¶
The method to smooth a ventricular volume as a function of time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurveFitMethod¶
Baseline correction used in the calculation of the results From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BaselineResultCorrection¶
The time in a dynamic set of images at which the first peak of the signal is observed for the analyzed myocardial wall segments From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalEarliestPeakTime¶
This is the time at which the signal begins to increase From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalIncreaseStartTime¶
Time interval between the beginning of the signal increase to the time at which the signal intensity reaches its first maximum in a dynamic set of images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalTimeToPeak¶
Peak of the MR perfusion signal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MRPerfusionPeak¶
Signal intensity as a function of time. It is the change in the signal intensity divided by the change in the time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MRPerfusionSlope¶
MR perfusion time integral from baseline (foot time) to earliest peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MRPerfusionTimeIntegral¶
First time point in a dynamic set of images used in the calculation of the baseline signal intensity for each myocardial wall segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalBaselineStart¶
Last time point in a dynamic set of images used in the calculation of the baseline signal intensity for each myocardial wall segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SignalBaselineEnd¶
The time delta between images in a dynamic set of images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageInterval¶
The minimum velocity encoded by the phase encoding gradient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VelocityEncodingMinimumValue¶
The maximum velocity encoded by the phase encoding gradient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VelocityEncodingMaximumValue¶
Forward volume-reverse volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NetForwardVolume¶
Area Based Method for estimating volume or area From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaBasedMethod¶
Diameter Based Method for estimating volume, area or diameter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiameterBasedMethod¶
Volume Based Method for estimating volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeBasedMethod¶
A method of diameter measurements according to NASCET (North American Symptomatic Carotid Endarterectomy Trial) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NASCET¶
A method of diameter measurements according to ECST (European Carotid Surgery Trial) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ECST¶
Agatston Score Threshold From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgatstonScoreThreshold¶
Calcium Mass Threshold From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumMassThreshold¶
Calcium Scoring Calibration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumScoringCalibration¶
Calcium Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumVolume¶
Calcium Mass From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CalciumMass¶
Delayed hyperenhancement of a tissue observed in an image acquired after injection of contrast media From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LateContrastEnhancement¶
Time interval since injection of contrast media From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeIntervalSinceInjectionOfContrastMedia¶
Time relative to R-wave peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeRelativeToR_wavePeak¶
Relationship between blood velocity and time relative to R-wave peak From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BloodVelocityVs_TimeOfCardiacCycle¶
Time interval since detection of contrast bolus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeIntervalSinceDetectionOfContrastBolus¶
Indicates if the papillary muscle was included or excluded in the measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PapillaryMuscleIncluded_Excluded¶
Anterior to Posterior direction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Anterior_Posterior¶
Persistent flow of blood into the stent-grafting From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Endoleak¶
Fracture of a stent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentFracture¶
Disintegration of a stent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentDisintegration¶
Material that a stent consists of From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StentComposition¶
Finding about the characteristics of the parent vessel of a vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ParentVesselFinding¶
Site of Maximal lumen diameter of a vessel From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SiteOfLumenMaximum¶
The physical domain (time, space, etc.) to the horizontal axis of the graphical presentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- X_Concept¶
The physical domain (time, space, etc.) to the vertical axis of the graphical presentation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Y_Concept¶
Indications for Pharmacological Stress From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IndicationsForPharmacologicalStress¶
Reference time for measurement of elapsed time in a procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProcedureTimeBase¶
Treadmill speed From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TreadmillSpeed¶
Treadmill gradient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TreadmillGradient¶
Ergometer power From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ErgometerPower¶
Pharmacological Stress Agent Dose Rate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PharmacologicalStressAgentDoseRate¶
Rating of Perceived Exertion From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RatingOfPerceivedExertion¶
Number of ectopic beats during a period of collection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfEctopicBeats¶
Heart rate times systolic blood pressure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DoubleProduct¶
Physical activity workload (intensity) measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ActivityWorkload¶
Elapsed time at stage From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeSinceStartOfStage¶
Exercise duration after stress agent injection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExerciseDurationAfterStressAgentInjection¶
Imaging Start Time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagingStartTime¶
Attenuation correction method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AttenuationCorrectionMethod¶
Pharmacological Stress Agent Dose From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PharmacologicalStressAgentDose¶
Maximum power output achieved during course of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumPowerOutputAchieved¶
Peak physical activity intensity measurement during course of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakActivityWorkload¶
Peak Double Product measurement during course of procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakDoubleProduct¶
Ordered subsets expectation maximization reconstruction algorithm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OSEMAlgorithm¶
Chang attenuation correction method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ChangMethod¶
Attenuation correction not based on image-based attenuation maps From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AlgorithmicAttenuationCorrection¶
NM transmission attenuation correction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NMTransmissionAttenuationCorrection¶
CT-based attenuation correction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CT_basedAttenuationCorrection¶
No attenuation correction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NoAttenuationCorrection¶
Bazett QT Correction Algorithm; QT/(RR ^ 0.5); Bazett HC. “An analysis of the time-relations of electrocardiograms” Heart7:353-370 (1920) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BazettQTcAlgorithm¶
Hodges QT Correction Algorithm; QT + 1.75 (heart rate-60); Hodges M, Salerno Q, Erlien D. “Bazett’s QT correction reviewed. Evidence that a linear QT correction for heart rate is better.” J Am Coll Cardiol1:694 (1983) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HodgesQTcAlgorithm¶
Fridericia QT Correction Algorithm; QT/(RR ^ 0.333); Fridericia LS. “The duration of systole in the electrocardiogram of normal subjects and of patients with heart disease” Acta Med Scand53:469-486 (1920) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FridericiaQTcAlgorithm¶
Framingham QT Correction Algorithm; QT + 0.154 (1- RR); Sagie A, Larson MG, Goldberg RJ, et al. “An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study).” Am J Cardiol70:797-801(1992) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FraminghamQTcAlgorithm¶
Borg Rating of Perceived Exertion Scale, range 6:20 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BorgRPEScale¶
Borg category ratio scale, open ended range with nominal range 0:10 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BorgCR10Scale¶
Overall study quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OverallStudyQuality¶
Excellent image quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExcellentImageQuality¶
Good image quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GoodImageQuality¶
Poor image quality From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PoorImageQuality¶
Image attenuation due to body physique (overweight) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BodyHabitusAttenuation¶
Image attenuation due to breast tissue From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BreastAttenuation¶
Image attenuation due to diaphragm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DiaphragmaticAttenuation¶
Finding of a defect is incorrect; e.g. from automated analysis From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FalsePositiveDefectFinding¶
ECG is non-diagnostic due to low heart rate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_diagnostic_LowHeartRate¶
ECG is non-diagnostic due to resting ST abnormalities From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_diagnostic_RestingSTAbnormalities¶
ECG is non-diagnostic due to ventricular pacing or Left Bundle Branch Block From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_diagnostic_VentricularPacingOrLBBB¶
ECG is non-diagnostic for presence of acute coronary syndrome From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_diagnosticECG¶
Strongly positive finding From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StronglyPositive¶
Strongly positive finding - ST elevation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StronglyPositive_STElevation¶
Finding of ST segment depression with no slope From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- STDepression_Horizontal¶
Finding of ST segment depression with upslope From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- STDepression_Upsloping¶
Finding of ST segment depression with downslope From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- STDepression_Downsloping¶
Stress test score From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StressTestScore¶
Number of diseased vessel territories From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NumberOfDiseasedVesselTerritories¶
Patient weight exceeds equipment limit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- WeightExceedsEquipmentLimit¶
Difference in Ejection Fraction From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInEjectionFraction¶
Difference in End Diastolic Left Ventricular Volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DifferenceInEDLVVolume¶
Ratio of achieved to predicted maximal oxygen consumption From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RatioOfAchievedToPredictedMaximalOxygenConsumption¶
Ratio of achieved to predicted functional capacity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RatioOfAchievedToPredictedFunctionalCapacity¶
Workload (Watts) at target heart rate divided by body weight From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AerobicIndex¶
ST depression at peak exercise divided by the exercise-induced increase in heart rate [Kligfield P, Ameisen O, Okin PM. “Heart rate adjustment of ST segment depression for improved detection of coronary artery disease.” Circulation 1989;79:245-55.] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ST_HRIndex¶
Agreement with prior findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AgreementWithPriorFindings¶
Disagreement with prior findings From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DisagreementWithPriorFindings¶
Nuclear Medicine Rest thallium/stress technetium procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RestThallium_stressTechnetiumProcedure¶
Nuclear Medicine Rest technetium/stress technetium 1 day procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RestTechnetium_stressTechnetium1DayProcedure¶
Nuclear Medicine Rest technetium/stress technetium 2 day procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RestTechnetium_stressTechnetium2DayProcedure¶
Nuclear Medicine Stress technetium/rest technetium 1 day procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StressTechnetium_restTechnetium1DayProcedure¶
Nuclear Medicine Myocardial Viability procedure From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NMMyocardialViabilityProcedure¶
Positron Emission Tomography Perfusion Imaging procedure, rest only From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialPerfusion_RestOnly¶
Positron Emission Tomography Perfusion Imaging procedure, stress only From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialPerfusion_StressOnly¶
Positron Emission Tomography Perfusion Imaging procedure, rest and stress From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialPerfusion_RestAndStress¶
Positron Emission Tomography Myocardial Viability procedure, rest only From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialViability_RestOnly¶
Positron Emission Tomography Myocardial Viability procedure, stress only From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialViability_StressOnly¶
Positron Emission Tomography Myocardial Viability procedure, rest and stress From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMyocardialViability_RestAndStress¶
Group of symptoms heralding angina pectoris that does not include chest pain (dyspnea, diaphoresis, profuse vomiting in a diabetic patient, or arm or jaw pain) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AnginalEquivalent¶
Active ingredient (molecular) used for radioactive tracing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Radiopharmaceutical¶
Time of radiopharmaceutical administration to the patient for imaging purposes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalStartTime¶
Ending time of radiopharmaceutical administration to the patient for imaging purposes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalStopTime¶
Volume of radiopharmaceutical administered to the patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalVolume¶
Total amount of radionuclide administered to the patient at Radiopharmaceutical Start Time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadionuclideTotalDose¶
Activity per unit mass of the radiopharmaceutical at Radiopharmaceutical Start Time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadiopharmaceuticalSpecificActivity¶
Pre-injection syringe acquisition count rate From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadionuclideSyringeCounts¶
Syringe acquisition count rate following patient injection From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadionuclideResidualSyringeCounts¶
Contrast or bolus agent From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Contrast_BolusAgent¶
Medication to be administered at the beginning of the Scheduled Procedure Step From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Pre_Medication¶
Anatomic Region to be imaged From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TargetRegion¶
Direction of imaging (includes view, transducer orientation, patient orientation, and/or projection) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagingDirection¶
Imaging condition for refinement of protocol (includes secondary posture, instruction, X-Ray / electron beam energy or nuclide, and ultrasound modes), as used in JJ1017 v3.0 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagingConditions¶
Caudal 10 degree distal-cranioproximal oblique radiographic projection, defined per Smallwood et al From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Caudal10DegreeDistal_cranioproximalOblique¶
Surface processing utilizing predefined weighting factors (i.e., kernels) applied to different data values depending on their location relative to other data values within the data domain. Includes Low Pass, High Pass, Gaussian, Laplacian, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NeighborhoodAnalysis¶
Surface processing applied non-uniformly utilizing a priori knowledge of the system and/or relative locations of the data values within the data domain. Example: Neighborhood analysis where weighting factors are modified continuously based on predefined criteria From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdaptiveFiltering¶
Surface processing through the exploitation of discontinuities in the data values within their domain. Includes Gradient filters From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EdgeDetection¶
Surface processing based on the connectivity of values based on the shape or structure of the data values within their domain. Includes erode, dilate, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MorphologicalOperations¶
Surface processing applied to the distribution of the data values. Includes thresholding, Bayesian Classification, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HistogramAnalysis¶
Surface processing accomplished through varying the data domain size. Include deformable models From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Multi_Scale_ResolutionFiltering¶
Surface processing accomplished by combining data values based on their relative location within their domain or value distribution. Includes K- and C-means, Fuzzy Analysis, Watershed, Seed Growing, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ClusterAnalysis¶
Surface processing accomplished through the weighted combination of multiple data sets. Includes Principle Component Analysis, linear and non-linear weighed combinations, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultispectralProcessing¶
Surface processing accomplished through human interaction. Region drawing From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ManualProcessing¶
Surface processing using Artificial Intelligence techniques, such as Machine Learning, Neural Networks, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ArtificialIntelligence¶
Surface processing using Deformable Model techniques, such as Point Distribution Models, Level Sets, Simplex Meshes, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DeformableModels¶
Document Title of OB-GYN procedure report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OB_GYNUltrasoundProcedureReport¶
Report section for assessment of fetal growth using ratios and indexes From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalBiometryRatios¶
Report section for assessment of fetal growth From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalBiometry¶
Report section for assessment of fetal growth by long bone measurements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalLongBones¶
Report section for assessment of fetal cranium growth From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalCranium¶
Biometric assessment of From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiometryGroup¶
Report section for assessment of biophysical observations that evaluate fetal well-being according to Manning, Antepartum Fetal Evaluation: Development of a Fetal Biophysical Profile Score, Am. J Obstet Gynecol, 1980;136:787 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiophysicalProfile¶
A grouping of related measurements and calculations that share a common context From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementGroup¶
Report section for fetus specific procedure summary observations From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetusSummary¶
Report section for assessment of early gestation fetus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EarlyGestation¶
A name to differentiate between multiple instances of some item From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Identifier¶
Report section for assessment of pelvis and uterus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PelvisAndUterus¶
The rank of a measured growth indicator relative to a normal distribution expressed as a percentage From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GrowthPercentileRank¶
The rank of a measured growth indicator relative to a normal distribution expressed as the dimensionless quantity z = (x-m) /s where (x-m) is the deviation of the value x, from the distribution mean, m, and s is the standard deviation of the distribution From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GrowthZ_score¶
Fetus characteristics (findings section title) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetusCharacteristics¶
Fetal Measurements (findings section title) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalMeasurements¶
There is a defined equivalence between the Frame of Reference of the Registration SOP instance and the Frame of Reference of the referenced images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FrameOfReferenceIdentity¶
The registration is based on fiducials that represent patient or specimen features identified in each data set From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FiducialAlignment¶
Registration based on a-priori knowledge of the acquisition geometry. This is not an object registration as in fiducial registration. Rather, it specifies a known spatial relationship From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionEquipmentAlignment¶
Computed registration based on global image information From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageContent_basedAlignment¶
Registration by visually guided manipulation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VisualAlignment¶
A plane fiducial that specifies the location of the plane separating the two hemispheres of the brain From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Inter_HemisphericPlane¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the anterior limit of the right brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightHemisphereMostAnterior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the posterior limit of the right brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightHemisphereMostPosterior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the superior limit of the right brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightHemisphereMostSuperior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the inferior limit of the Right brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RightHemisphereMostInferior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the anterior limit of the left brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftHemisphereMostAnterior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the posterior limit of the left brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftHemisphereMostPosterior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the superior limit of the left brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftHemisphereMostSuperior¶
A point fiducial that specifies the location in the plane perpendicular to the Anterior- Posterior-Commissure axis and tangential to the inferior limit of the left brain hemisphere From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftHemisphereMostInferior¶
That which is not part of an object From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Background¶
A segment for use as an input to an image registration process; e.g. to specify the bounding region for determining a Frame of Reference Transformation Matrix From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegistrationInput¶
Root Document Title for ultrasound vascular evidence reports (worksheets) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VascularUltrasoundProcedureReport¶
The particular vessel branch, such as the inferior, medial or lateral From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VesselBranch¶
A descriptor or elaboration of the type of graft From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GraftType¶
A modifier to a 2D distance measurement to describe its orientation; e.g. a vascular distance measurement for a vessel plague could have a modifier Transverse or Longitudinal From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MeasurementOrientation¶
The angle formed between the Doppler beam line and the direction of blood flow within a region of interest in the body defined by the sample volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DopplerAngle¶
The depth of the center of the Doppler sample volume measured from skin line along the Doppler line From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SampleVolumeDepth¶
Pediatric Cardiac Ultrasound Report (document title) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PediatricCardiacUltrasoundReport¶
Fetal Cardiac Ultrasound Report (document title) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FetalCardiacUltrasoundReport¶
Adult Congenital Cardiac Ultrasound Report (document title) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdultCongenitalCardiacUltrasoundReport¶
Document title of adult echocardiography procedure (evidence) report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AdultEchocardiographyProcedureReport¶
An image that is a pictorial representation of findings. The concept is typically used as a purpose of reference to an image, such as a depiction of myocardium segments depicting wall motion function From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IllustrationOfFinding¶
The average of all scored (non-zero) Left Ventricle segment wall motion scores From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LVWallMotionScoreIndex¶
A type of clinical acquisition protocol for creating images or image-derived measurements. Acquisition protocols may be specific to a manufacturer’s product From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionProtocol¶
Method for calculating left ventricular volume from two orthogonal views containing the true long axis (usually the apical 4 and 2 chamber views). Volume = [pL1 / 6] * [(4A1) ÷ (pL1) ] * [(4A2) ÷ (pL2) ] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Area_lengthBiplane¶
Method for calculating left ventricular volume from a view containing the true long axis (usually the apical 4-chamber view). Volume = [8(A)2]÷[3pL] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Area_LengthSinglePlane¶
Method (formula) for calculating left ventricle volumes and function derivatives (EF, SV, SI, etc.) that estimates the volume as the cube of diameter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cube¶
Method of calculating volume based on the summation of disk volumes. The disk axis is parallel to the left ventricular long axis and using a disk diameter averaged from the two chamber and four chamber views From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MethodOfDisks_Biplane¶
Method of calculating volume based on the summation of disk volumes. The disk axis is parallel to the left ventricular long axis with disk diameter taken from the four-chamber view From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MethodOfDisks_SinglePlane¶
Method (formula) for calculating left ventricle volumes and function derivatives (EF, SV, SI, etc.) Volume = [7.0/(2.4+D) ]*D3 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Teichholz¶
Mitral valve area (cm2) by Pressure Half-time = 220 (cm2.ms) / PHT (ms) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AreaByPressureHalf_Time¶
Area = P/4 X d1 X d2 d1 = anterior/posterior axis d2 = medial/lateral axis Hagen-Ansert, Sandra L., Textbook of Diagnostic Ultrasound, ed. 3, The C.V.Mosby Co., 1989, p. 73. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BiplaneEllipse¶
For conduits in series (“in continuity”), volume flow is equal: A1*V1 = A2*V2. where V is the velocity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContinuityEquation¶
For conduits in series (“in continuity”), volume flow is equal: A1*V1 = A2*V2. where V is the mean velocity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContinuityEquationByMeanVelocity¶
For conduits in series (“in continuity”), volume flow is equal: A1*V1 = A2*V2. where V is the peak velocity From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContinuityEquationByPeakVelocity¶
For conduits in series (“in continuity”), volume flow is equal: A1*V1 = A2*V2. where V is the velocity time integral From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContinuityEquationByVelocityTimeIntegral¶
Utilizes aliasing velocity (by color Doppler) of flow into an orifice (often regurgitant or stenotic) to measure instantaneous flow rate, orifice area, and flow volume. The instantaneous flow rate = (2πr2vav ) * (α / π) where vav is the constant velocity known as aliasing velocity at radius r, vp is the peak velocity at the orifice, and α is the angle in radians of the constant velocity surface. Estimated Orifice area = Flow rate / vp , where vp is the peak velocity at the orifice and the flow rate is the PISA peak flow rate. The volume flow is then the product of the orifice area and Velocity Time Integral From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProximalIsovelocitySurfaceArea¶
ΔP = 4*(V12 - V22) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FullBernoulli¶
ΔP = 4*V2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SimplifiedBernoulli¶
Volume flow = Conduit CSA * (Velocity Time Integral) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DopplerVolumeFlow¶
Direct measurement of an area by tracing an irregular perimeter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Planimetry¶
Mass = 1.04 * [(ST+LVID+PWT)3 - LVID3] * 0.8+ 0.6. Mass unit is grams and length in cm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByM_mode¶
Mass = 1.05P ((b + t)2 X (2/3 (a + t) + d - d3 /3(a + t)2) - b2 (2/3a + d - d3 /3a2)) a = Semi-major axis from widest minor axis radius to apex. b = Short axis radius calculated from short axis cavity area t = Myocardial thickness calculated from short axis epicardial and cavity areas d = Truncated semi- major axis from widest short axis diameter to plane of mitral annulus. Mass unit is grams and length in cm. Schiller NB et al: Recommendations for quantification of the left ventricle by two-dimensional echocardiography, American Society of Echocardiography 2:364, 1989. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByTruncatedEllipse¶
A four point, echocardiographic numeric scoring scheme of myocardium segments based on evaluation of wall motion and ventricle morphology. Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography, Journal of the American Society of Echocardiography, 2:358-367, 1989 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SinglePlaneEllipse¶
Modified Simpson’s Method of estimating ventricular volume, based on the method of disks with paired apical views. Schiller NB, et al. “Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms”. J Am Soc Echocardiogr.1989 2(5):358-367. Sep-Oct From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ModifiedSimpson¶
Bullet method of estimating ventricular volume. Volume = 5/6 * L * S L: Left ventricle long axis length S: Left ventricle area, SAX view at level of Mitral Valve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BulletMethod¶
Color coded ultrasound images of blood flow, which depict the amplitude, or power, of Doppler signals From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PowerDoppler¶
Volumetric ultrasound imaging From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfDrugDoseAdministration¶
Onset of contrast agent administration From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StartOfContrastAgentAdministration¶
Destruction of ultrasonic contrast microbubbles by a high-energy ultrasound pulse From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DestructionOfMicrobubbles¶
Instant at which exercise begins From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OnsetOfExercise¶
Instant at which exercise ends From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CessationOfExercise¶
Instant at which stimulation begins From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OnsetOfStimulation¶
Instant at which stimulation ends From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CessationOfStimulation¶
Ultrasound transducer scan pattern in which information is gathered along a line From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LineScanPattern¶
Ultrasound transducer scan pattern in which information is gathered within a plane From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PlaneScanPattern¶
Ultrasound transducer scan pattern in which information is gathered within a volume From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- VolumeScanPattern¶
Ultrasound transducer geometry characterized by a single scan line used for PW or CW Doppler scanning From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Non_imagingDopplerUltrasoundTransducerGeometry¶
Ultrasonic transducer geometry characterized by parallel lines From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LinearUltrasoundTransducerGeometry¶
Ultrasonic transducer geometry characterized by radial lines normal to the outside of a curved surface From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CurvedLinearUltrasoundTransducerGeometry¶
Ultrasonic transducer geometry characterized by lines originating from a common apex From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SectorUltrasoundTransducerGeometry¶
Ultrasonic transducer geometry characterized by lines emanating radially from a single point From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RadialUltrasoundTransducerGeometry¶
Ultrasonic transducer geometry characterized by a circular ring of transducer elements From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RingUltrasoundTransducerGeometry¶
Ultrasonic steering technique consisting of a single beam normal to the transducer face steered by the orientation of the probe From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FixedBeamDirection¶
Ultrasonic steering technique consisting of mechanically directing the beam From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MechanicalBeamSteering¶
Ultrasonic steering technique consisting of electronically-steered beams From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PhasedBeamSteering¶
Transducer is designed to be placed onto the surface of the subject From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExternalTransducer¶
Transducer is designed for insertion into the esophagus From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TransesophagealTransducer¶
Transducer is designed for insertion into the vagina From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndovaginalTransducer¶
Transducer is designed for insertion into the rectum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EndorectalTransducer¶
Transducer is designed for insertion via a catheter From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IntravascularTransducer¶
method to measure the mass of the Left Ventricle via the ASE area-length method at end diastole. LV Mass = 1.05*(5/6*(A1*(L+t)) - 5/6*(A2*L)) A1 = Left Ventricle epicardial SAX area at the level of the papillary muscle tips at end diastole. A2 = Left Ventricle endocardial SAX area cavity area at the level of the papillary muscle tips at end diastole. L = Left Ventricle apical view long axis length at end diastole. t = Myocardial thickness can be computed as: t = sqrt (A1/3.14) - sqrt (A2/3.14) Reference: 1) Schiller, N.B., et al. “Recommendations for Quantification of the LV by Two-dimensional Echocardiography.” J Am Soc Echo, Vol. 2, No. 5: 358-367, Sep-Oct 1989. 2) Reichek, N., et al. “Anatomic Validation of Left Ventricular Mass Estimates from Clinical Two-dimensional Echocardiography: Initial Results.” Circulation, Vol. 67, No. 2: 348-52, February 1983 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByAreaLength¶
Equation = Left Ventricle Mass by M-mode (in gram) / (Height (in meter)) ^2.7 Reference: Giovanni De Simone, et al. “Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk”. New York, New York and Cincinnati, Ohio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByM_mode_AdjustedByHeight¶
Equation = Left Ventricle Mass by Truncated Ellipse / Height^2.7 Reference: Giovanni De Simone, et al. “Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk”. New York, New York and Cincinnati, Ohio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByTruncatedEllipse_AdjustedByHeight¶
Equation = Left Ventricle Mass by Area Length / Height^2.7 Reference: Giovanni De Simone, et al. “Effect of Growth on Variability of Left Ventricular Mass: Assessment of Allometric Signals in Adults and Children and Their Capacity to Predict Cardiovascular Risk”. New York, New York and Cincinnati, Ohio From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeftVentricleMassByAreaLength_AdjustedByHeight¶
CARDIOsphere ultrasonic contrast agent produced by POINT Biomedical From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CARDIOsphere¶
Echovist® ultrasonic contrast agent produced by Schering AG From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Echovist¶
Imagify ultrasonic contrast agent produced by Accusphere Inc From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Imagify¶
Levovist® ultrasonic contrast agent produced by Schering AG From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Levovist¶
Sonazoid ultrasonic contrast agent produced by Daiichi Pharmaceutical / General Electric From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Sonazoid¶
SonoVue ultrasonic contrast agent produced by Bracco Diagnostics From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SonoVue¶
Targestar-B ultrasonic contrast agent produced by Targeson LLC From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Targestar_B¶
Targestar-P ultrasonic contrast agent produced by Targeson LLC From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Targestar_P¶
A structured report containing the quantitative results of human or machine analysis of images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagingMeasurementReport¶
A structured report containing the quantitative results of human or machine analysis of images for oncology evaluation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OncologyMeasurementReport¶
A structured report containing the quantitative results of human or machine analysis of DCE-MR From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DynamicContrastMRMeasurementReport¶
A structured report containing the quantitative results of human or machine analysis of PET images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETMeasurementReport¶
Measurements made on images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImagingMeasurements¶
Measurements derived from measurements made on images From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DerivedImagingMeasurements¶
An MRI procedure in which multiple parameters including diffusion, dynamic contrast and T2 are measured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultiparametricMRI¶
An MRI procedure of the prostate in which multiple parameters including diffusion, dynamic contrast and T2 are measured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultiparametricMRIOfProstate¶
An MRI procedure of the whole body in which multiple parameters including diffusion, dynamic contrast and T2 are measured From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MultiparametricMRIOfWholeBody¶
The volume derived by summing the volumes of all the voxels (and partial voxels if the segment contains partially occupied voxels) included in the segment From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SumOfSegmentedVoxelVolumes¶
Maximum average gray value that is calculated from a 1 cubic centimeter sphere placed within the region of interest. Reference Wahl et al PERCIST article From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PeakValueWithinROI¶
The volume of a lesion (e.g. a tumor) ascertained through information about its metabolic activity (e.g. SUV on PET). Abbreviated “MV”. Synonymous with Metabolic Tumor Volume (MTV) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MetabolicVolume¶
The total activity of a lesion obtained as the product of its volume and its glycolytic activity (on FDG-PET). The volume may be defined on the same modality (e.g. the MV on FDG-PET by some thresholding or other technique) or on another spatially registered modality (e.g. the lesion outline segmented on CT or MR). Does not apply to other radiopharmaceuticals than those involved in glucose metabolism. Abbreviated TLG. Synonymnous with “Tumor Lesion Glycolysis” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalLesionGlycolysis¶
The amount glycolytic activity summed across all voxels in a defined region or within a defined range of SUV (on FDG-PET) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Glycolysis¶
The total activity of a lesion obtained as the product of its volume and its proliferative activity (on FLT-PET). The volume may be defined on the same modality (e.g. the MV on FDG-PET by some thresholding or other technique) or on another spatially registered modality (e.g. the lesion outline segmented on CT or MR). Does not apply to other radiopharmaceuticals than those involved in cellular proliferation. Abbreviated TLP. Synonymnous with “Tumor Lesion Proliferation” From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TotalLesionProliferation¶
The amount proliferative activity summed across all voxels in a defined region or within a defined range of SUV (on FLT-PET) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProliferativeActivity¶
A background-corrected, partial volume independent version of TLG. SAM is calculated by drawing a volume of interest (VOI1) around the tumour and a larger VOI (VOI2) around VOI1. Subtracting the background activity in VOI2-VOI1 from VOI1 yields SAM. See Mertens et al. “Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases”. Eur J Nucl Med Mol Imaging (2012) 39:1441-1448 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardizedAddedMetabolicActivity_SAM_¶
The background value (VOI2-VOI1) used to calculate Standardized Added Metabolic Activity (SAM). SAM is calculated by drawing a volume of interest (VOI1) around the tumour and a larger VOI (VOI2) around VOI1. Subtracting the background activity in VOI2-VOI1 from VOI1 yields SAM. See Mertens et al. “Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases”. Eur J Nucl Med Mol Imaging (2012) 39:1441-1448 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardizedAddedMetabolicActivity_SAM_Background¶
The ratio of the SUV within a tumor to the SUV of a pre-defined background region. Need reference(s). A more general concept than Tumor to Background Ratio (TBR) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LesionToBackgroundSUVRatio¶
The SUV of a pre-defined background region used to compute Lesion to Background SUV Ratio. Need reference(s) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BackgroundForLesionToBackgroundSUVRatio¶
A statistical index of complexity comparing how detail in a fractal pattern changes with the scale at which it is measured; a ratio of the change in detail to the change in scale From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FractalDimension¶
Measure of the asymmetry of the probability distribution of a real-valued random variable about its mean From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Skewness¶
Measure of the peakedness of the probability distribution of a real-valued random variable From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Kurtosis¶
The zero order entropy of a Gray Level Co-occurrence Matrix (GLCM). A measure of disorder. See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EntropyOfGLCM¶
The energy (uniformity) (square root of the Angular Second Moment (ASM)) of a Gray Level Co-occurrence Matrix (GLCM). A measure of orderliness. See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- EnergyOfGLCM¶
The Inverse Difference Moment of a Gray Level Co-occurrence Matrix (GLCM). See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- HomogeneityOfGLCM¶
The sum of squares variance of a Gray Level Co-occurrence Matrix (GLCM). See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastOfGLCM¶
The dissimilarity of a Gray Level Co-occurrence Matrix (GLCM). See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- DissimilarityOfGLCM¶
The Angular Second Moment of a Gray Level Co-occurrence Matrix (GLCM). See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ASMOfGLCM¶
A measure of the linear dependency of grey levels on those of neighbouring pixels of a Gray Level Co-occurrence Matrix (GLCM). See http://www.fp.ucalgary.ca/mhallbey/equations.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CorrelationOfGLCM¶
A tabulation of how often different combinations of pixel values (grey levels) occur in an image. See http://www.fp.ucalgary.ca/mhallbey/the_glcm.htm From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GrayLevelCo_occurrenceMatrix_GLCM_¶
An identifier of a specific time point in a continuum, which is unique within an appropriate local context (such as an entire organization, system or treatment protocol), which identifies the time point for a specific patient From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SubjectTimePointIdentifier¶
An identifier of a specific time point in a continuum, which is unique within an appropriate local context (such as an entire organization, system or treatment protocol), which identifies the time point “slot” within a treatment protocol using the same value for all patients in the protocol From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ProtocolTimePointIdentifier¶
A pre-defined type of a specific time point in a continuum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimePointType¶
A number indicating the order of a time point relative to other time points in the same continuum From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimePointOrder¶
The time after the treatment of interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Posttreatment¶
For the purpose of determining eligibility for a protocol From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Eligibility¶
Response Evaluation Criteria in Solid Tumors version 1.0. See [RECIST] in Normative References From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RECIST1_0¶
Response Evaluation Criteria in Solid Tumors Version 1.1. See Eisenhauer et al. “New Response Evaluation Criteria in Solid Tumours: Revised RECIST Guideline (version 1.1).” European Journal of Cancer 45, no. 2 (n.d.): 228-47. doi:10.1016/j.ejca.2008.10.026. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RECIST1_1¶
A reference to the Real World Value Map applied to the stored image pixel values before their use for a measurement From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RealWorldValueMapUsedForMeasurement¶
A container that groups common information about a set of images used as evidence to produce a report From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ImageLibraryGroup¶
The date the acquisition of data started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionDate¶
The time the acquisition of data started From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AcquisitionTime¶
The time between the start of injection of the PET radionuclide and the start of acquisition of the PET data From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PETRadionuclideIncubationTime¶
Coefficient of determination, R2. An indication of goodness of fit From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R2_Coefficient¶
Perfusion analysis by Stable Xenon CT technique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerfusionAnalysisByStableXenonCTTechnique¶
Perfusion analysis by IV Iodinated Contrast CT technique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerfusionAnalysisByIVIodinatedContrastCTTechnique¶
Perfusion analysis by Arterial Spin Labeling (ASL) MR technique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerfusionAnalysisByArterialSpinLabelingMRTechnique¶
Perfusion analysis by Susceptibility (T2*) MR technique From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PerfusionAnalysisBySusceptibilityMRTechnique¶
Least Mean Square (LMS) deconvolution From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- LeastMeanSquare_LMS_Deconvolution¶
Singular Value Decomposition (SVD) deconvolution From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SingularValueDecomposition_SVD_Deconvolution¶
Ktrans, the volume transfer constant of a tracer diffusion kinetic model, specifically the volume transfer constant between blood plasma and extravascular extracellular space (EES) See Tofts et al, “Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols”, Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ktrans¶
kep, the rate constant between extravascular extracellular space (EES) and blood plasma See Tofts et al, “Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols”, Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Kep¶
ve, the fractional (not absolute) volume of extravascular extracellular space (EES) per unit volume of tissue See Tofts et al, “Estimating Kinetic Parameters From Dynamic Contrast-Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols”, Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Ve¶
The intial area under the contrast agent concentration-time curve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IAUC¶
The intial area under the contrast agent concentration-time curve at 60 seconds after the onset time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IAUC60¶
The intial area under the contrast agent concentration-time curve at 90 seconds after the onset time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IAUC90¶
τm. The mean intracellular water lifetime (τi). Used in the Shutter-Speed Model (SSM) of tracer kinetics From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Tau_m¶
vp. The fractional (not absolute) blood plasma volume per unit volume of tissue. See Tofts et al, “Estimating Kinetic Parameters From Dynamic Contrast- Enhanced T1-Weighted MRI of a Diffusable Tracer: Standardized Quantities and Symbols”, Journal of Magnetic Resonance Imaging, vol. 10, pp. 223-232, 1999 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Vp¶
A tracer diffusion kinetic model in which the permeability is assumed to be isodirectional. See P. Tofts, “Modeling tracer kinetics in dynamic Gd-DTPA MR imaging”, Journal of Magnetic Resonance Imaging, vol. 7, pp. 91-101, 1997 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardToftsModel¶
A tracer diffusion kinetic model in which the permeability is not assumed to be isodirectional, and which includes the contribution of tracer in the blood plasma to the total tissue concentration. See P. Tofts, “Modeling tracer kinetics in dynamic Gd-DTPA MR imaging”, Journal of Magnetic Resonance Imaging, vol. 7, pp. 91-101, 1997 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ExtendedToftsModel¶
A semiquantitative analysis of the contrast-enhancement concentration versus time curve that avoids the use of a pharmacokinetic model; e.g. integration to compute the initial area under the curve From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Model_freeConcentration_timeQuantitification¶
A tracer diffusion kinetic model that accounts for the tumor leakage profile during the first pass of contrast. See Li, Ka-Loh, Xiao Ping Zhu, John Waterton, and Alan Jackson. “Improved 3D Quantitative Mapping of Blood Volume and Endothelial Permeability in Brain Tumors.” Journal of Magnetic Resonance Imaging 12, no. 2 (2000): 347-357. doi:10.1002/1522-2586(200008)12:2<347::AID- JMRI19>3.0.CO;2-7 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FirstPassLeakageProfile_FPLP_¶
A tracer diffusion kinetic model that does not assume that intercompartmental water molecule exchange is infinitely fast. See Li, Xin, Wei Huang, Thomas E. Yankeelov, Alina Tudorica, William D. Rooney, and Charles S. Springer. “Shutter-Speed Analysis of Contrast Reagent Bolus-Tracking Data: Preliminary Observations in Benign and Malignant Breast Disease.” Magnetic Resonance in Medicine 53, no. 3 (2005): 724-29. doi:10.1002/mrm.20405 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Shutter_SpeedModel_SSM_¶
T1 measurement by Multiple Flip Angles (MFA) (variable saturation) method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1ByMultipleFlipAngles¶
T1 measurement by Inversion Recovery (IR) method From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1ByInversionRecovery¶
Calculation was performed using a fixed value of T1 rather than a measured value. The value could be encoded as the value of (126353, DCM, “T1 Used For Calculation”) From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1ByFixedValue¶
The fixed value of T1 used for a calculation From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T1UsedForCalculation¶
No Arterial Input Function was used From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AIFIgnored¶
A population-averaged Arterial Input Function From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PopulationAveragedAIF¶
An Arterial Input Function computed from a user-defined Region of Interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- User_definedAIFROI¶
An Arterial Input Function computed from an automatically detected Region of Interest From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- AutomaticallyDetectedAIFROI¶
A data-driven blind source separation (BSS) algorithm that estimates AIF from individuals without any presumed AIF model and initialization. See Lin, Yu- Chun, Tsung-Han Chan, Chong-Yung Chi, Shu-Hang Ng, Hao-Li Liu, Kuo-Chen Wei, Yau-Yau Wai, Chun-Chieh Wang, and Jiun-Jie Wang. “Blind Estimation of the Arterial Input Function in Dynamic Contrast-Enhanced MRI Using Purity Maximization.” Magnetic Resonance in Medicine 68, no. 5 (November 1, 2012): 1439-49. doi:10.1002/mrm.24144 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BlindEstimationOfAIF¶
The time at which the concentration-time curve achieves its peak for the first time. Used as a concept name for a value or as a method; e.g. used as a method of calculation for BAT. See Shpilfoygel Med Phys 2008. doi: 10.1118/1.1288669 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeOfPeakConcentration¶
The nominal time at which arrival of a contrast bolus is detected, which is used as a reference point for subsequent calculations. Used as a concept name for a value or as a method. No specific computational method is implied by this general definition. Abbreviated BAT From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- BolusArrivalTime¶
The time at which the concentration-time curve achieves half of its peak density for the first time. Used as a concept name for a value or as a method; e.g. used as a method of calculation for BAT. See Shpilfoygel Med Phys 2008. doi: 10.1118/1.1288669 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TimeOfLeadingHalf_PeakConcentration¶
A method of determining BAT that involves computing the temporal derivative of the concentration-time curve and selecting the time when the temporal derivative exceeds a specified threshold. See Shpilfoygel Med Phys 2008. doi: 10.1118/1.1288669 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TemporalDerivativeExceedsThreshold¶
A threshold applied to the temporal derivative of the concentration-time curve; e.g. used to establish BAT. See Shpilfoygel Med Phys 2008. doi: 10.1118/1.1288669 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TemporalDerivativeThreshold¶
The maximum rate of signal intensity change within a measured region of a time-activity curve. See Boonsirikamchai, Piyaporn, Harmeet Kaur, Deborah A. Kuban, Edward Jackson, Ping Hou, and Haesun Choi. “Use of Maximum Slope Images Generated From Dynamic Contrast-Enhanced MRI to Detect Locally Recurrent Prostate Carcinoma After Prostatectomy: A Practical Approach.” American Journal of Roentgenology 198, no. 3 (March 1, 2012): W228-W236. doi:10.2214/AJR.10.6387 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumSlope¶
The maximum degree of signal intensity change within a measured region of a time-activity curve. See Boonsirikamchai, Piyaporn, Harmeet Kaur, Deborah A. Kuban, Edward Jackson, Ping Hou, and Haesun Choi. “Use of Maximum Slope Images Generated From Dynamic Contrast-Enhanced MRI to Detect Locally Recurrent Prostate Carcinoma After Prostatectomy: A Practical Approach.” American Journal of Roentgenology 198, no. 3 (March 1, 2012): W228-W236. doi:10.2214/AJR.10.6387 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MaximumDifference¶
Tracer concentration in tissue; e.g. in a DCE-MR experiment, the concentration of contrast agent in mmol/l From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- TracerConcentration¶
The degree to which a paramagnetic contrast agent can enhance the proton longitudinal relaxation rate constant (R1, 1/T1), normalized to the concentration of the contrast agent. Also referred to as r1. Typically expressed in units of l/mmol/s From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ContrastLongitudinalRelaxivity¶
The flow rate of blood perfusing a region as volume per mass per unit of time From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalBloodFlow¶
The volume of blood perfusing a region as volume per mass From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- RegionalBloodVolume¶
The percent of the oxygen removed from the blood by tissue during its passage through the capillary network. For example, as measured by blood oxygenation level dependent (BOLD) MR. See He, Xiang, and Dmitriy A. Yablonskiy. “Quantitative BOLD: Mapping of Human Cerebral Deoxygenated Blood Volume and Oxygen Extraction Fraction: Default State.” Magnetic Resonance in Medicine 57, no. 1 (2007): 115-26 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- OxygenExtractionFraction¶
The longitiudinal relaxation rate constant. The inverse of longitudinal relaxation time, i.e., R1 = 1/T1 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R1¶
The transverse relaxation rate constant. The inverse of transverse relaxation time, i.e., R2 = 1/T2 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R2¶
A ratio of locally measured radioactivity concentration versus the injected radioactivity distributed evenly throughout the whole body. This general concept encompasses all specific methods of calculating the whole body volume of distribution, such as using body weight, lean body mass, body surface area, etc. From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- StandardizedUptakeValue¶
Standardized Uptake Value calculated using body weight. The patient size correction factor for males and females is body weight. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVbw¶
Standardized Uptake Value calculated using lean body mass. The patient size correction factor for males is 1.10 * weight - 120 * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVlbm¶
Standardized Uptake Value calculated using body surface area. The patient size correction factor for males and females is weight^ 0.425 * height^0.725 * 0.007184. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVbsa¶
Standardized Uptake Value calculated using ideal body weight. The patient size correction factor for males is 48.0 + 1.06 * (height - 152) and for females is 45.5 + 0.91 * (height - 152). Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVibw¶
Method of calculating Standardized Uptake Value using body weight. The patient size correction factor for males and females is body weight. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVBodyWeightCalculationMethod¶
Method of calculating Standardized Uptake Value using lean body mass. The patient size correction factor for males is 1.10 * weight - 120 * (weight/height) ^2, and for females is 1.07 * weight - 148 * (weight/height) ^2. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVLeanBodyMassCalculationMethod¶
Method of calculating Standardized Uptake Value using body surface area. The patient size correction factor for males and females is weight^ 0.425 * height^0.725 * 0.007184. Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVBodySurfaceAreaCalculationMethod¶
Method of calculating Standardized Uptake Value using ideal body weight. The patient size correction factor for males is 48.0 + 1.06 * (height - 152) and for females is 45.5 + 0.91 * (height - 152). Defined in Sugawara et al. Reevaluation of the Standardized Uptake Value for FDG: Variations with Body Weight and Methods for Correction.Radiology, 1999 at http://radiology.rsna.org/content/213/2/521 From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- SUVIdealBodyWeightCalculationMethod¶
A beta-amyloid PET radiotracer that is an analog of thioflavin T From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- PittsburghCompoundBC_11_¶
A beta-amyloid PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlorbetabenF_18_¶
A PHF-tau PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- T807F_18_¶
A nicotinic α4β2 receptor (nAChR) PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlubatineF_18_¶
A Cu 64 Monoclonal Antibody (mAb) PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MonoclonalAntibody_mAb_64_Cu¶
A Zr 89 Monoclonal Antibody (mAb) PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- MonoclonalAntibody_mAb_89_Zr¶
A Zr 89 Trastuzumab PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Trastuzumab_89_Zr¶
A Zr 89 Cetuximab PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Cetuximab_89_Zr¶
A Zr 89 J591 PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- J591_89_Zr¶
A Zr 89 cU36 PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CU36_89_Zr¶
A Zr 89 Bevacizumab PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Bevacizumab_89_Zr¶
A Zr 89 cG250-F(ab’)(2) PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CG250_F_ab_2_89_Zr¶
A Zr 89 R1507 PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- R1507_89_Zr¶
A Zr 89 E4G10 PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- E4G10_89_Zr¶
A Zr 89 Df-CD45 PET Radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Df_CD45_89_Zr¶
^44^Scandium From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ATSMCu_60_¶
A Cu 61 ATSM PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ATSMCu_61_¶
A Cu 62 ATSM PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- ATSMCu_62_¶
A C 11 Choline PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CholineC_11_¶
A C 11 Fallypride PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FallyprideC_11_¶
An F 18 Fallypride PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FallyprideF_18_¶
A C 11 FLB 457 PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FLB457C_11_¶
An F 18 Fluorotriopride PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FluorotrioprideF_18_¶
An F 18 Fluoromisonidazole PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- Fluoromisonidazole_FMISO_F_18_¶
A C 11 Glutamine PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlutamineC_11_¶
A C 14 Glutamine PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlutamineC_14_¶
An F 18 Glutamine PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- GlutamineF_18_¶
An F 18 Flubatine PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- FlubatineF_18_¶
An F 18 2FA PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- NifeneF_18_¶
An I 124 cancer targeted phospholipid ether PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CLR1404I_124_¶
An I 131 cancer targeted phospholipid ether PET radiotracer From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- CLR1404I_131_¶
Patient Support Continuous Angle in IEC PATIENT SUPPORT Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127PatientSupportContinuousAngle¶
Table Top Continuous Pitch Angle in the direction of the IEC TABLE TOP Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopContinuousPitchAngle¶
Table Top Continuous Roll Angle in the direction of the IEC TABLE TOP Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopContinuousRollAngle¶
Table Top Eccentric Axis Distance [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopEccentricAxisDistance¶
Table Top Continuous Eccentric Angle in the direction of the IEC TABLE TOP ECCENTRIC Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopContinuousEccentricAngle¶
Table Top Lateral Position IEC TABLE TOP Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopLateralPosition¶
Table Top Longitudinal Position IEC TABLE TOP Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopLongitudinalPosition¶
Table Top Vertical Position in IEC TABLE TOP Coordinate System [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127TableTopVerticalPosition¶
Gantry Continuous Roll Angle in degrees of the radiation source, i.e., the rotation about the Y-axis of the IEC GANTRY coordinate system [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127GantryContinuousRollAngle¶
Gantry Pitch Continuous Angle in degrees of the radiation source, i.e., the rotation about the X-axis of the IEC GANTRY coordinate system [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127GantryContinuousPitchAngle¶
Gantry Yaw Continuous Angle in degrees of the radiation source, i.e., about the Z-axis of the IEC GANTRY coordinate system [IEC 61217] From: http://dicom.nema.org/resources/ontology/DCM in valuesets.xml
- IEC6127GantryContinuousYawAngle¶